AQUA JOY 1SAJ150 Скачать руководство пользователя страница 17

10 

SALT REQUIREMENT CHART 

Eg: To achieve 4,000 parts per million salt in 60,000 litres of pool water, 
add 240kg salt. 

Parts per million Salt 

Litres of 

Water 

500  1000 

1500  2000 

2500  3000 

3500  4000 

4500  5000 

5500 

5000 

2.5 

7.5 

10 

12.5 

15 

17.5 

20 

22.5 

25 

27.5 

10,000 

10 

15 

20 

25 

30 

35 

40 

45 

50 

55 

15,000 

7.5 

15 

22.5 

30 

37.5 

45 

52.5 

60 

67.5 

75 

82.5 

20,000 

10 

20 

30 

40 

50 

60 

70 

80 

90 

100 

110 

25,000  12.5 

25 

37.5 

50 

62.5 

75 

87.5 

100  112.5 

125  137.5 

30,000 

15 

30 

45 

60 

75 

90 

105 

120 

135 

150 

165 

40,000 

20 

40 

60 

80 

100 

120 

140 

160 

180 

200 

220 

45,000  22.5 

45 

67.5 

90  112.5 

135  157.5 

180  202.5 

225  247.5 

50,000 

25 

50 

75 

100 

125 

150 

175 

200 

225 

250 

275 

*60,000 

30 

60 

90 

120 

150 

180 

210 

240 

270 

300 

330 

65,000  32.5 

65 

97.5 

130  162.5 

195  227.5 

260  292.5 

325  357.5 

70,000 

35 

70 

105 

140 

175 

210 

245  280 

315 

350 

385 

75,000  37.5 

75  112.5 

150  187.5 

225  262.5  300 

337.5 

375  412.5 

80,000 

40 

80 

120 

160 

200 

240 

280  320 

360 

400 

460 

Kilograms of Salt 

 

* Example for 60,000 Litre Pool 

Содержание 1SAJ150

Страница 1: ...141 035 172 ABN 66 141 035 172 Website www aquajoy com au Unit 21 2 Richard Close E mail sales aquajoy com au NORTH ROCKS NSW 2151 AUSTRALIA Ph 61 2 9630 5011 Fax 61 2 9683 4750 SALTWATER CHLORINATOR...

Страница 2: ...AQUAJOY is switched on Please check that the pump is functioning correctly before assuming that the AQUAJOY unit is not working Your AQUAJOY is fitted with a light which indicates when the unit is swi...

Страница 3: ...installed by competent personnel to the instructions contained in this manual Power Pack is to be installed according to AS NZ 3000 2000 and located outside pool Zone 2 area Servicing should only be a...

Страница 4: ...d not be operated by personnel eg operating front panel switches adjusting time clock safety cutout cleaning cells etc when the surrounding area is damp In addition personnel should not operate the un...

Страница 5: ...DOUBT ABOUT THE SAFETY OF THE UNIT OR IF THE UNIT MALFUNCTIONS ADOPT THE FOLLOWING SAFETY INSTRUCTIONS Turn off the power to the unit at the power point Disconnect the power cord and call for service...

Страница 6: ...separation between mains and extra low voltage parts All insulating panels are in place and terminal connections are tight Earth pin of power cord to all external metal parts of the chlorinator to hav...

Страница 7: ...ART UP PROCEDURE 5 CHLORINE PRODUCTION TEST 6 GENERAL INFORMATION ON WATER CARE 7 Filtration 7 Chlorination 7 pH 7 Conclusions 8 MAINTENANCE 8 Cleaning of the Cell 8 Adding Salt 9 Power Pack Maintenan...

Страница 8: ...piled to assist you on Basic Pool Care AQUAJOY SALT WATER CHLORINATOR MODELS 1 STANDARD 2 AUTO DELUXE Time Clock AQUAJOY STANDARD Ideal for established and new pools where a time clock is already fitt...

Страница 9: ...y over riding the time clock normal position AUTO when in time clock mode D Chlorine production dial Anticlockwise to reduce clockwise to increase E Time clock see page 12 F 3A Circuit Breaker A Cell...

Страница 10: ...s in winter 2 MOUNT THE POWER PACK a Screw mounting bracket to wall or post with slots facing upwards within 1 5 metres of the power outlet and within 1 5 metres of the Filter Return to Pool Line b Pl...

Страница 11: ...lied already connected to the Terminal Box under the Power Pack b If it is necessary to disconnect the cell lead re assemble as follows i Attach Blue wire of cell lead to Blue wire of Terminal Box ii...

Страница 12: ...ow 24 hours 3 Valves re opened INSTALLATION DIAGRAM NOTE WATER MAY FLOW EITHER WAY THROUGH INLET OUTLET PORTS ON CELL CELL MAY BE REVERSED AS SHOWN IN DIAGRAM GAS AND ELECTRIC HEATERS REQUIRE CELL INS...

Страница 13: ...sector CHLORINE PRODUCTION TEST 1 Turn on Filter and Chlorinator 2 Place thumb over chlorine test vial and place next to return to pool outlet 3 Allow water to fill vial and replace thumb over vial be...

Страница 14: ...tration causes excessive electricity bills and wear and tear on equipment CHLORINATION Chlorine is required to react with the debris removing stains by oxidation and to sterilise the water of harmful...

Страница 15: ...ubsequently the production of Chlorine It may also damage the anode electrodes and cause damage beyond repair 1 Switch off the filtration and Chlorinator and close valves 2 Unscrew cap in an anti cloc...

Страница 16: ...kg bag of salt into pool at shallow end Ensure Chlorine production dial is turned down 2 Allow salt to dissolve and increase Chlorine output Inspect Chlorine Monitor If not in normal sector repeat as...

Страница 17: ...100 110 25 000 12 5 25 37 5 50 62 5 75 87 5 100 112 5 125 137 5 30 000 15 30 45 60 75 90 105 120 135 150 165 40 000 20 40 60 80 100 120 140 160 180 200 220 45 000 22 5 45 67 5 90 112 5 135 157 5 180...

Страница 18: ...and WINTER sectors and each sector has 3 coloured areas YELLOW GREEN ORANGE see colour coding in lower left hand corner and the monitor needle position will vary according to the condition of your po...

Страница 19: ...white tappets The dial is for 24 hours and each tappet represents 15 minutes The correct time is set at the white indicator arrow situated at 2 0 O clock on the black face To set the Time Clock push...

Страница 20: ...er levels is low or cell is clogged with scale Short intervals between backwashes Ineffective backwashing Body fat or oil build up on pads With Diatomaceous earth filters the cause may be insufficient...

Страница 21: ...TRUCTIONS CORRECTLY Should your Pump Motor fail or other problems do not allow you to operate your AQUAJOY in the normal manner Sodium Hypochlorite liquid chlorine may be added to keep the pool steril...

Страница 22: ...NTENANCE DATE CLEANED METHOD USED RESULT POWER PACK TERMINAL BOX FASTENINGS DATE CHECKED NEEDED ATTENTION YES NO Connections on Terminal Box should be checked at three 3 monthly intervals to ensure th...

Страница 23: ...rectifier devises JOY POOL SYSTEMS shall not be liable for loss of profits or benefits indirect special consequential or other similar damages arising out of any breach of warranty or otherwise PLEASE...

Страница 24: ...ctured by JOY POOL SYSTEMS ACN 141 035 172 ABN 66 141 035 172 Unit 21 2 Richard Close NORTH ROCKS NSW 2151 AUSTRALIA Website www aquajoy com au E mail sales aquajoy com au Ph 61 2 9630 5011 Fax 61 2 9...

Отзывы: