AQUA JOY 1SAJ150 Скачать руководство пользователя страница 10

INSTALLATION 

These  instructions  should  be  read  and  understood  completely  before 
starting  installation.   

Correct  installation  is  mandatory  for  correct  and 

safe operation. 

 

1.  POOL WATER PREPARATION 

a)

 

Measure the pool size in litres to determine salt requirements. 

b)

 

Refer to salt requirement chart. (page 10).  Add 4kg of 

refined salt

 

per 1000 litres of water in shallow end of pool. 

c)

 

Connect  up  vacuum  hose  and  place  vacuum  head  close  to  salt.  
This will cause salt to dissolve quicker. 

d)

 

BEFORE  CHLORINATOR  IS  TURNED  ON

  the  salt  must  be 

dissolved completely (24 hours in summer, 72 hours in winter)

.

 

 

2.  MOUNT THE POWER PACK 

a)

 

Screw mounting bracket to wall or post with slots facing upwards 
within 1.5 metres of the power outlet and within 1.5 metres of the 
Filter Return to Pool Line. 

b)

 

Place back of Power Pack to mounting bracket and slot into place.  

Note:  Do not mount in

 direct sunlight.

 

 

3.  INSTALL THE CELL 

a)

 

Determine Filter Return to Pool Line. 

b)

 

Cell must be in a horizontal position with inlet and outlet sockets 
facing downward as per diagram (page 5). 

c)

 

Cell must be installed before all breakout lines such as dual outlets, 
Spa lines. 

d)

 

Cell  must  be  installed  after  the  heater  (where  fitted)  and  Solar 
systems (see  Diagram Page  5).  Pool cleaner pump  motors which 
draw  water  from  the  return  to  pool  line  should  be  fitted  after  the 
Cell for correct pool chlorination. 

Содержание 1SAJ150

Страница 1: ...141 035 172 ABN 66 141 035 172 Website www aquajoy com au Unit 21 2 Richard Close E mail sales aquajoy com au NORTH ROCKS NSW 2151 AUSTRALIA Ph 61 2 9630 5011 Fax 61 2 9683 4750 SALTWATER CHLORINATOR...

Страница 2: ...AQUAJOY is switched on Please check that the pump is functioning correctly before assuming that the AQUAJOY unit is not working Your AQUAJOY is fitted with a light which indicates when the unit is swi...

Страница 3: ...installed by competent personnel to the instructions contained in this manual Power Pack is to be installed according to AS NZ 3000 2000 and located outside pool Zone 2 area Servicing should only be a...

Страница 4: ...d not be operated by personnel eg operating front panel switches adjusting time clock safety cutout cleaning cells etc when the surrounding area is damp In addition personnel should not operate the un...

Страница 5: ...DOUBT ABOUT THE SAFETY OF THE UNIT OR IF THE UNIT MALFUNCTIONS ADOPT THE FOLLOWING SAFETY INSTRUCTIONS Turn off the power to the unit at the power point Disconnect the power cord and call for service...

Страница 6: ...separation between mains and extra low voltage parts All insulating panels are in place and terminal connections are tight Earth pin of power cord to all external metal parts of the chlorinator to hav...

Страница 7: ...ART UP PROCEDURE 5 CHLORINE PRODUCTION TEST 6 GENERAL INFORMATION ON WATER CARE 7 Filtration 7 Chlorination 7 pH 7 Conclusions 8 MAINTENANCE 8 Cleaning of the Cell 8 Adding Salt 9 Power Pack Maintenan...

Страница 8: ...piled to assist you on Basic Pool Care AQUAJOY SALT WATER CHLORINATOR MODELS 1 STANDARD 2 AUTO DELUXE Time Clock AQUAJOY STANDARD Ideal for established and new pools where a time clock is already fitt...

Страница 9: ...y over riding the time clock normal position AUTO when in time clock mode D Chlorine production dial Anticlockwise to reduce clockwise to increase E Time clock see page 12 F 3A Circuit Breaker A Cell...

Страница 10: ...s in winter 2 MOUNT THE POWER PACK a Screw mounting bracket to wall or post with slots facing upwards within 1 5 metres of the power outlet and within 1 5 metres of the Filter Return to Pool Line b Pl...

Страница 11: ...lied already connected to the Terminal Box under the Power Pack b If it is necessary to disconnect the cell lead re assemble as follows i Attach Blue wire of cell lead to Blue wire of Terminal Box ii...

Страница 12: ...ow 24 hours 3 Valves re opened INSTALLATION DIAGRAM NOTE WATER MAY FLOW EITHER WAY THROUGH INLET OUTLET PORTS ON CELL CELL MAY BE REVERSED AS SHOWN IN DIAGRAM GAS AND ELECTRIC HEATERS REQUIRE CELL INS...

Страница 13: ...sector CHLORINE PRODUCTION TEST 1 Turn on Filter and Chlorinator 2 Place thumb over chlorine test vial and place next to return to pool outlet 3 Allow water to fill vial and replace thumb over vial be...

Страница 14: ...tration causes excessive electricity bills and wear and tear on equipment CHLORINATION Chlorine is required to react with the debris removing stains by oxidation and to sterilise the water of harmful...

Страница 15: ...ubsequently the production of Chlorine It may also damage the anode electrodes and cause damage beyond repair 1 Switch off the filtration and Chlorinator and close valves 2 Unscrew cap in an anti cloc...

Страница 16: ...kg bag of salt into pool at shallow end Ensure Chlorine production dial is turned down 2 Allow salt to dissolve and increase Chlorine output Inspect Chlorine Monitor If not in normal sector repeat as...

Страница 17: ...100 110 25 000 12 5 25 37 5 50 62 5 75 87 5 100 112 5 125 137 5 30 000 15 30 45 60 75 90 105 120 135 150 165 40 000 20 40 60 80 100 120 140 160 180 200 220 45 000 22 5 45 67 5 90 112 5 135 157 5 180...

Страница 18: ...and WINTER sectors and each sector has 3 coloured areas YELLOW GREEN ORANGE see colour coding in lower left hand corner and the monitor needle position will vary according to the condition of your po...

Страница 19: ...white tappets The dial is for 24 hours and each tappet represents 15 minutes The correct time is set at the white indicator arrow situated at 2 0 O clock on the black face To set the Time Clock push...

Страница 20: ...er levels is low or cell is clogged with scale Short intervals between backwashes Ineffective backwashing Body fat or oil build up on pads With Diatomaceous earth filters the cause may be insufficient...

Страница 21: ...TRUCTIONS CORRECTLY Should your Pump Motor fail or other problems do not allow you to operate your AQUAJOY in the normal manner Sodium Hypochlorite liquid chlorine may be added to keep the pool steril...

Страница 22: ...NTENANCE DATE CLEANED METHOD USED RESULT POWER PACK TERMINAL BOX FASTENINGS DATE CHECKED NEEDED ATTENTION YES NO Connections on Terminal Box should be checked at three 3 monthly intervals to ensure th...

Страница 23: ...rectifier devises JOY POOL SYSTEMS shall not be liable for loss of profits or benefits indirect special consequential or other similar damages arising out of any breach of warranty or otherwise PLEASE...

Страница 24: ...ctured by JOY POOL SYSTEMS ACN 141 035 172 ABN 66 141 035 172 Unit 21 2 Richard Close NORTH ROCKS NSW 2151 AUSTRALIA Website www aquajoy com au E mail sales aquajoy com au Ph 61 2 9630 5011 Fax 61 2 9...

Отзывы: