3
INSTALLATION
These instructions should be read and understood completely before
starting installation.
Correct installation is mandatory for correct and
safe operation.
1. POOL WATER PREPARATION
a)
Measure the pool size in litres to determine salt requirements.
b)
Refer to salt requirement chart. (page 10). Add 4kg of
refined salt
per 1000 litres of water in shallow end of pool.
c)
Connect up vacuum hose and place vacuum head close to salt.
This will cause salt to dissolve quicker.
d)
BEFORE CHLORINATOR IS TURNED ON
the salt must be
dissolved completely (24 hours in summer, 72 hours in winter)
.
2. MOUNT THE POWER PACK
a)
Screw mounting bracket to wall or post with slots facing upwards
within 1.5 metres of the power outlet and within 1.5 metres of the
Filter Return to Pool Line.
b)
Place back of Power Pack to mounting bracket and slot into place.
Note: Do not mount in
direct sunlight.
3. INSTALL THE CELL
a)
Determine Filter Return to Pool Line.
b)
Cell must be in a horizontal position with inlet and outlet sockets
facing downward as per diagram (page 5).
c)
Cell must be installed before all breakout lines such as dual outlets,
Spa lines.
d)
Cell must be installed after the heater (where fitted) and Solar
systems (see Diagram Page 5). Pool cleaner pump motors which
draw water from the return to pool line should be fitted after the
Cell for correct pool chlorination.