MT9T111: Developer Guide
Calibration Procedure Summary
Preliminary
Calibration Procedure Summary
1. Power the sensor.
2. Open DevWare and load the default registers.
3.
Press
the
Preview Button
to turn off the preview and go into full resolution mode.
(Default is in preview mode.)
4.
Press
the
Stop Button.
5. Load the bypass full resolution settings below:
[Bypass Full resolution]
REG = 0x001C, 1281// MCU_BOOT_MODE
REG = 0x0010, 288// PLL_DIVIDERS
REG = 0x0012, 144// PLL_P_DIVIDERS
REG = 0x002A, 30719// PLL_P4_P5_P6_DIVIDERS
REG = 0x002C, 12407// PLL_P7_DIVIDER
REG = 0x0112, 532// RX_FIFO_WATERMARK
REG = 0x3C5C, 32// OB_TRIG_MARK
REG = 0x3330, 256// OUTPUT_FORMAT_TEST
REG = 0x300C, 3985// LINE_LENGTH_PCK
REG = 0x3C68, 2056// OB_LINE_PIXEL_CNT
REG = 0x3C66, 1544// OB_FRAME_LINE_CNT
6.
Press
the
Options Button
from the top down menu and enter the correct Bayer Size
(2056 x 1544).
7.
Select Bayer 8 + 2
.
8. Press Apply.
9. Press Play. (You are now in Bayer mode.)
10. Open the Sensor Control Window.
11. Press “Find Optical Center”.
12. Select Allowed Fallout.
13. Press “Calibration Lens Correction”
14. Save PGA coefficients generated by Devware to .ini file by pressing “Save As” button.