MT9T111: Developer Guide
Lens Calibration Procedure
Preliminary
Figure 60:
Check Image to See if it is Flipped Correctly
11. Save and capture processed RGB image after lens correction is applied.
12. Repeat steps 9–11 until the following combinations have been captured:
12a. No Horizontal Flip – No Vertical Flip.
12b. No Horizontal Flip – Vertical Flip.
12c. Horizontal Flip – Vertical Flip.
12d. Horizontal Flip – No Vertical Flip.
13. If required, perform the calibration procedure for the following additional illumi-
nants. If you are trying to use adaptive PGA these additional calibrations must be per-
formed:
– Daylight (D65, 6500K)
– Fluorescent (4200K)
– Incandescent (2850K)
14. Change lighting to incandescent (A light).
15. Repeat steps 2 – 6.
16. Apply calibration settings from step 7.
17. Repeat step 8.
18. For multiple sensors repeat the sequence (steps 10 – 12) for D65 light and A light.