APT VARIPLUS 105 Скачать руководство пользователя страница 1

Power Converter

For the following model: 

105

SAFETY

CHECKLIST

 

KEEP 

unqualified/unauthorized personnel away from test area

 

ARRANGE

 test stations in a safe and orderly manner

 

NEVER

 touch products or connections during a test

 

STOP

 the test first in the event of a problem

 

BE SURE

 to use the appropriate AWG for your input and output cabling

 

TURN OFF

 the output when making any connections to the load

       WARNING:

 THIS GUIDE WAS CREATED           

          FOR OPERATORS HAVING SOME FAMILIARITY  

          WITH AC POWER SOURCES AND HIGH 

VOLTAGE/HIGH CURRENT TESTING APPLICATIONS. 

AN AC POWER SOURCE PRODUCES VOLTAGES AND 

CURRENTS THAT CAN CAUSE HARMFUL OR FATAL 

ELECTRIC SHOCK. TO PREVENT ACCIDENTAL INJURY 

OR DEATH, THESE SAFETY PROCEDURES MUST BE 

STRICTLY OBSERVED WHEN HANDLING AND USING 

AN AC POWER SOURCE.

Содержание VARIPLUS 105

Страница 1: ...the appropriate AWG for your input and output cabling TURN OFF the output when making any connections to the load WARNING THIS GUIDE WAS CREATED FOR OPERATORS HAVING SOME FAMILIARITY WITH AC POWER SOURCES AND HIGH VOLTAGE HIGH CURRENT TESTING APPLICATIONS AN AC POWER SOURCE PRODUCES VOLTAGES AND CURRENTS THAT CAN CAUSE HARMFUL OR FATAL ELECTRIC SHOCK TO PREVENT ACCIDENTAL INJURY OR DEATH THESE SAF...

Страница 2: ... SYSTEM KEY Cycles through the user system parameters All parameters may be edited 5 DISPLAY KEY Toggles the Current Power Display to show either the output current measurement or the output power measurement 6 FREQUENCY KEY Toggles the output frequency to 50 or 60 Hz 7 OUTPUT RESET KEY Enables and disables the output relay 8 LOCK KEY Locks out the front panel controls when active The display may ...

Страница 3: ... the fuse unplug the power mains cord and turn the fuse cap counter clockwise to remove fuse The fuse compartment will be exposed Please replace the fuse with one of the proper rating 4 INPUT POWER RECEPTACLE Standard IEC 320 connector for connection to a standard NEMA style line power mains cord 5 INPUT POWER SWITCH Line voltage input selection is set by the position of the switch 115 230 V ...

Страница 4: ... voltage or turn the rotary knob counter clockwise to decrease the voltage The voltage will increase and decrease more rapidly depending on the speed of rotation SETTING THE FREQUENCY Press the 50 60 Hz Frequency key to toggle the frequency The LED will indicate which frequency the instrument is outputting INSTRUMENTSETUP Voltage Adjust rotary knob 50 60 Hz Frequency key ...

Страница 5: ...or for W is lit the wattage will be displayed SETTING THE LOCK Press the LOCK key to lock out the front panel during testing If the LOCK key is active the LED indicator will be lit When Lock is active the operator cannot change any settings from the front panel If the LOCK key is active when the unit is powered OFF it will remain active when the unit is powered back ON A W Display key 4 INSTRUMENT...

Страница 6: ...nstrument to a normal state Press the SYSTEM key to change the system parameters The LED indicator will be on when the SYSTEM key is activated The SYSTEM key is only available if the output is off or the LED indicator is off on the OUTPUT RESET key Press the SYSTEM key to cycle through the parameters Use the rotary knob to adjust the system parameter settings 5 INSTRUMENTSETUP SYSTEMSETUP Output R...

Страница 7: ...e 0 0 300 0 V Press the SYSTEM key again to accept the setting and move to the next parameter setting SETTING THE SMARTVOLT Press the SYSTEM key until the voltage display reads Vout Use the rotary knob to select from the following parameters The LAST setting will configure the VariPLUS to power up at the same output voltage that was last used before the unit was powered off The 0 setting will conf...

Страница 8: ... Test VariPLUS Domestic and International Product Testing http aptsources com variplussupport ONLINE VIDEO RESOURCES For additional information about these and other key features of the VARIPLUS please consult the full Operation and Service Manual or call us toll free 1 877 322 7693 or 1 847 367 4378 2012 Associated Power Technologies www aptsources com VARIPLUS 3 12 Scan the QR code with your sma...