APT Controls EVOLT WBM-PIP Скачать руководство пользователя страница 1

 

 

 

WBM-PIP - INSTALLATION QUICK GUIDE

 

 

 

1. DESCRIPTION 

 
The  electric  vehicle  charging  system  WBM-PIP  is  specially  designed  for  use  on  indoor  and  outdoor  car  parks  to 
provide a safe charging system. It consists of a sturdy housing designed to be installed on a flat wall surface. 
 

 

 

2. WARNINGS

 

 

  Do not use cables there are not in perfect conditions. 

 

  Do not use WallBox for anything other than electric vehicle charging. Charging mode is IEC 61851-1 MODE 3. 

 

  Do not modify the WallBox. If modified, APT CONTROLS will reject all responsibility and the warranty will be 

void. 

 

  Comply strictly with current safety regulations according to your country rules. 

 

  Do not make repairs or install with the device powered. 

 

  Only trained and qualified personnel should have access to low-voltage electrical parts inside the device. 

 

  Check the installation annually by qualified technician. 

 

  Remove  from service  any item that  has a fault  that could be dangerous  for users  (broken  plugs, caps that 

don’t close...). 

 

  Only use APT CONTROLS spare parts. 

 

 

 

 

 

 

3. TECHNICAL CHARACTERISTICS 

 

Input Voltage 

230V AC 

Single-phase 

 

Extended temperature 

range* 

Heater (optional)  

(-

30…+60 ºC)*

 

Tolerance 

±15% 

Temperature range 

-

10…+60 ºC 

Input frequency 

50…60 Hz 

Enclosure IP protection 

IP54 

Output Voltage 

= input voltage 

Socket IP Protection 

IP44 

Maximum consumption 

7,2Kw 

Box dimensions 

350x442x125 mm 

Maximum current output 

32A 

Weight 

6Kg 

Socket 

Type II VDE-AR-E 

2623-2-2 according 

IEC62196-2 

Anchor 

4 points wall mount 

Charge System 

MODE 3 (IEC 61851) 

Enclosure 

ABS 

RFID reader 

ISO 14443A 

RFID frequency 

13,56Mhz 

Energy meter 

Integrated meter 

Communications 

10/100 Base-T 

IEEE802.3u 

Software Update 

Via web 

 

 

 
 
 
 

 

 

 

 

 

 

This is a quick 

WBM-PIP

 guide. 

Before performing any maintenance, modification, connection, repair, 
etc., disconnect the device from the power supply. When you suspect 
a  malfunction  of  the  equipment  or  protection  the  equipment  should 
be immediately disconnected from the power supply. 

STANDARDS

 

EN 61851-1: 2001 PARTE 1, IEC 61000, IEC 60884-1, IEC 60364-4-41, IEC 61010, IEC 61008-1, IEC 
60529,UNE-EN55011, UNE-EN62196-1, UNE-EN61851-1, UNE-EN61851-21, UNE-EN61851-22 