Important Safety Instructions

This manual contains important instructions to be followed during installation and

maintenance of the APsystems optimizer. To reduce the risk of electrical shock and ensure the

safe installation and operation of the optimizer, the following symbols appear throughout

this document to indicate dangerous conditions and important safety
instructions.

Specifications are subject to change without notice - please ensure you

are using the most recent update found at www.APsystems.com

WARNING:

This symbol indicates a situation where failure to

follow instructions may cause a serious hardware failure or

personal danger if not applied appropriately. Use extreme

caution when performing this task.

NOTE:

This symbol indicates information that is important for

Optimizer operation. Follow these instructions closely.

Safety Instructions

Do NOT disconnect the PV module from the APsystems optimizer

without first disconnecting the AC power.

Only qualified professionals should install and/or replace the APsystems

optimizer.

Perform all electrical installations in accordance with local codes.

Before installing or using the APsystems optimizer, please read all

instructions and cautionary markings in the technical documents and on

the APsystems microinverter system and the solar array.

Be aware that the body of the running APsystems optimizer is the heat

sink and can reach high temperatures. To reduce risk of burns, do not

touch the body of the optimizer.

Do NOT attempt to repair the APsystems optimizer. If it fails, contact

APsystems Customer Support to obtain an RMA number and start the

replacement process. Damaging or opening the APsystems optimizer

will void the warranty.

WARNING

SYMBOL

NOTE

SYMBOL

Содержание OPT700

Страница 1: ...Installation User Manual Rev 1 1 ALTENERGY POWER SYSTEM Inc www APsystems com All Rights Reserved OPT700 OPT700L DC Optimizer...

Страница 2: ...tems 7 Required parts and tools to complete the installation 7 Installation Procedures 8 Step 1 Attaching the APsystems Optimizer to the Racking or the PV Module Frame 8 Step 2 Connecting the APsystem...

Страница 3: ...icates information that is important for Optimizer operation Follow these instructions closely Safety Instructions Do NOT disconnect the PV module from the APsystems optimizer without first disconnect...

Страница 4: ...rantee that interference will not occur in a particular installation If this equipment causes harmful interference to radio or television reception the following measures might resolve the issues A Re...

Страница 5: ...ty Instructions Symbols replace words on the equipment on a display or in manuals Trademark Caution risk of electric shock Equipment protected throughout by double insulation or reinforced insulation...

Страница 6: ...e energy harvested from each module It can achieve module level Maximum Power Point Tracking MPPT and plays a critical part in the whole power system The APsystems PV Power Optimizer system is compris...

Страница 7: ...derperforms compared with the other units the APsystems optimizer ensures top performance from the array by maximizing the performance of each module The APsystems Optimizer system is reliable safe an...

Страница 8: ...stallation of this equipment includes the risk of electric shock WARNING Do not touch any live parts in the system including the PV array when the system has been connected to the electrical grid WARN...

Страница 9: ...ching to the PV Module Frame Figure 3 Step 2 Connecting the APsystems Optimizer to the PV Module Figure 4 WARNING Connect the PV module to the optimizer INPUT1 interface when the optimizer connects wi...

Страница 10: ...s designed to accomodate labels in vertical or horizontal orientation to meet all the field PV connections a Each APsystems optimizer has removable serial number labels Peel the labels off affix one t...

Страница 11: ...ess of the APsystems optimizer connection can be verified by measuring the polarity and magnitude of the total string output voltage For example each APsystems optimizer connect to two PV modules and...

Страница 12: ...r Connect all the PV modules to their optimizers securely There is something wrong with PV Power Optimizer Please return the optimizer to your distributor for replacement or contact APsystems Customer...

Страница 13: ...ect the PV module DC wire connectors from the optimizer and disconnect the optimizer output cables 4 Remove the optimizer from the PV array racking B Install a replacement optimizer to the rack and co...

Страница 14: ...mm x 26 4mm Weight 1 1lbs 0 5kg Enclosure Rating IP67 NEMA 6P Protection Class II Overvoltage Category II Operational environment Outdoor Use Pollution Degree Classification PD3 Wet Locations Classifi...