background image

English – Q1 2021

Caution: 

Features are unavailable to residential split phase

Содержание ECU-C Zigbee

Страница 1: ...English Q1 2021 Caution Features are unavailable to residential split phase...

Страница 2: ...Product Overview Installation ECU C configuration...

Страница 3: ...Product Overview...

Страница 4: ...inverter data Real time monitoring of each inverter Adapted to EU single or 3 phase Built in WiFi Zigbee communication Rail din mounted Metering Function Electricity data monitoring 0 Export function...

Страница 5: ...Power Interface NA 3 phase systems 208 or 277Y 480V L1 L2 L3 N PE Network Interface Reset Button WiFi antenna Production CT s Consumption CT s ZigBee antenna Redundant Energy Control Status led...

Страница 6: ...50m max open field good signal 100 inverters per ECU ZigBee relay...

Страница 7: ...ter location using extension cable for WiFi antenna 2 4GHz with SMA connectors male female not provided by APsystems If the antenna is installed outside not protected from the rain change if for an ap...

Страница 8: ...80A or 200A Production Consumption...

Страница 9: ......

Страница 10: ......

Страница 11: ...Router Internet AC distribution box or PV AC box ECU C Antennas outside the box...

Страница 12: ...NA split phase PV systems No CTs required Features are unavailable for split phase systems Power interface wiring with Standard NA 208 or 277Y 480V 60Hz L1 L2 L3 N PE 3 phase PV systems N L3 L2 L1 PE...

Страница 13: ...Install CT for ECU C...

Страница 14: ...3 phase PV system 6 CTs Consumption L3 L2 L1 Production L3 L2 L1 Warning Check phases are matching on ECU C power port and CTs port...

Страница 15: ...Install CT for ECU C Connector Connector...

Страница 16: ...Proprietary and confidential Property of APsystems 16...

Страница 17: ...Energy Metering...

Страница 18: ...Proprietary and confidential Property of APsystems 18...

Страница 19: ...ugh the Ethernet cable Make sure the connection between the ECU the router is ok Power ECU it will obtain automatically IP address from the router Ensure the router connects to the internet then the E...

Страница 20: ...Connect the ECU R or the ECU C to the router through WiFi set up through ECU configuration...

Страница 21: ......

Страница 22: ...Download APsystems EMA Manager APP in your smartphone utilize the ECU APP embedded in app Connect your smartphone to ECU R or ECU C WiFi hot spot Open ECU App 1 ECU configuration 2 System check up...

Страница 23: ...Enter EMA Manager in your smartphone Play Store select APsystems EMA Manager and click install Or scan QR code in the Installation Manual And download ECU App...

Страница 24: ......

Страница 25: ...R_216000XXXXXX for ECU C ECU WIFI_XXXX 216000XXXXXX ECU R ID XXXX 4 last digits of ECU C ID Warning If your ECU has a button AP on the side of the casing the Wifi hotspot is activated for 1 hour after...

Страница 26: ...ECU R Enter password 88888888 ECU C no password then click connect...

Страница 27: ...Check your smartphone is connected to ECU hot spot...

Страница 28: ...Proprietary and confidential Property of APsystems 28 1 ECU Configuration...

Страница 29: ...Open ECUAPP on your smartphone and check on Home Page you are connected to the ECU then click Settings...

Страница 30: ...From the Settings Page click Date Time then click Sync phone time and OK...

Страница 31: ...From Setting menu click ID Management...

Страница 32: ...digits ID located on the front of the ECU case UID helps to identify each microinverter and his version starting with 501 or 502 YC1000 starting with 406 408 or 409 YC600 starting with 801 802 QS1 40...

Страница 33: ...Select SCAN to enter inverter ID by camera Then scan all inverter ID To speed up the process read barcodes on inverter map...

Страница 34: ...Inverter ID are displayed in the list check the box in order to select all inverters and click SYNC...

Страница 35: ...Click OK and check ID registration in ECU is successful...

Страница 36: ...from Settings menu click Grid Profile then Click Please Select That setting may also be done remotely from EMA monitoring...

Страница 37: ...Select the right setting In the rolling menus Then click OK Selected grid profil is displayed then click Update...

Страница 38: ...Proprietary and confidential Property of APsystems 38 2 System check up...

Страница 39: ...Back to Home Page slide your finger from top to bottom screen to refresh data Check number of inverter registered 2nd then after about 2 minutes check ECU is connected to all inverters here 2 out of 2...

Страница 40: ...Check if all Inverters and their PV modules are Producing Verify the AC and Frequency On the Homepage tap on Data...

Страница 41: ...click LAN in the Setting menu check setting is Obtain an IP address automatically and IP address is not 192 168 131 228 If ECU is connected to the internet router via Ethernet cable...

Страница 42: ...From Settings menu click WLAN In case wire connection via RJ45 port is not possible you may connect ECU to the internet router through WiFi Select the right network...

Страница 43: ...Enter the Password and click SEND Then it will display this message...

Страница 44: ...Close WLAN menu then open it again and check WiFi connection...

Страница 45: ...ECU C is connected to internet and EMA monitoring Lights up green send data to EMA Lights up green ECU is powered...

Страница 46: ...Proprietary and confidential Property of APsystems 46 THANK YOU...

Отзывы: