Problem
Possible Causes
Possible Solutions
Screen shows message
C014 SHORT ALARM
Output wiring short
circuit or connected load
shorted
Turn off the output and check the output
cables to make sure they are connected
correctly before turning power back on.
Screen shows message
C015 RCP ALARM
RCP circuit failed
Contact customer service
Screen shows message
C016 OUTPUT 1 OVP
Remote voltage sense
compensation exceeds
5V
Make sure remote voltage sense
compensation is no more than 5 volts.
Screen shows message
SELF TEST FAIL
Power on self-test failed Contact customer service
Screen shows message
UNACTIVATED
Activation Failure
Contact customer service
Table 13-1: Troubleshooting Matrix