CPS100 SERIES OPERATION MANUAL
SECTION 13:
Error Messages & Troubleshooting
Entire Contents Copyright
2018 by Adaptive Power Systems, Inc. (APS) • All Rights Reserved • No reproduction without written authorization from APS.
APS CPS100 Series Power Source Operation Manual
Page 215 of 231 PN 160953-10
12
Fixed Waveform Library
Overview
The CPS100 Series power sources provide a built-in library of 30 waveforms that can be used
in AC or AC+DC mode instead of a normal sine wave. These waveforms contain various
higher order harmonics of the programmed fundamental frequency and allow product
testing for immunity to voltage distortion conditions.
The FIXED waveforms are numbered from 0 through 29 and can be selected by Selecting the
USER entry, pressing [Enter] to confirm and entering a number between 0 and 29 using the
[0] ~ [9] keys.
Waveform Details
This summary shows the harmonic content of each FIXED waveform expressed in % of
fundamental amplitude (relative) and phase shift with respect to the fundamental frequency
F
0.
A visual representation of the waveshape is shown as well for reference.
12.2.1
FIXED Waveform No 0
Harmonic
% Ampl
Phase
5
9.8
0
7
15.8
0
8
2.16
0