CPS100 SERIES OPERATION MANUAL
SECTION 7:
Entire Contents Copyright
2018 by Adaptive Power Systems, Inc. (APS) • All Rights Reserved • No reproduction without written authorization from APS.
APS CPS100 Series Power Source Operation Manual
Page 169 of 231
Table 7-13: Waveform Synthesis System Commands
System Commands
The system commands provide system level functions.
Command
Description
SYS:DIM:EDGE:_<nr2>
Sets the edge of the dimmer test function to either Leading (0)
or Trailing (1). Range is 0 ~ 1. Returns OK or False.
SYS:DIM:DEGREE:_<nr2>
Sets the phase angle of the blanking period. Range is 0.0 ~
180.0. Returns OK or False.
SYS:LOC
Enables local operation (front panel active). Puts the unit in
LOCAL mode when controlled from a computer program.
Returns OK or False.
SYS:RECALLDEFAULT
Recalls factory default setting. This will erase all use settings.
Returns OK or False.
SYS:RECALLIP
Resets the LAN interface IP address. Returns OK or False.
Table 7-14: System Commands