6.10.2
Auto Run Mode Selections
To change mode, press the “
Edit
” soft key while the first field is selected. This displays the
MODE screen as shown below. In this case, PROGRAM mode is already selected but you can
use the “
Change
” soft key to toggle to the available modes that are display at the bottom of
the screen. Available modes are:
•
PROGRAM
AC Mode with programmed steps execution
•
MANUAL
AC Mode with manual data entry using the key pad.
•
DC
Same as MANUAL mode but for DC output mode
As you toggle through the available modes, use the “
Enter
” soft key to confirm the mode
selection or the “
Esc
” soft key to return with any change. This will bring up the next System
parameter setup screen. The same screen can be selected using the “
Next
” soft key if
needed.
6.10.3
Single Step Modes
Pressing Enter after selecting the PROGRAM mode will bring up the Single Step parameter
setup screen. Available settings are shown in the bottom part of the screen.
Use the “
Change
” soft key to toggle between ON or OFF.
•
ON
= Program execution will take place in single step mode allowing the operator
to advance to each step from the front panel.
•
OFF
= Program execution will proceed automatically using the dwell times
programmed for each step.
When
Single Step
mode is
ON
, the source will sequence from one test step to the next
only when the Test/Reset key is pressed by an operator between each step. The source
will pause after each step has completed a test routine and passed based on the