6RL Series Regenerative DC Load Operation Manual
Page 73 of 204
Time out and protocol setting parameters:
Element
Description
Com Timeout
Timeout USB/RS232 (in milliseconds) Default value: 5, Range: 5...65535
Defines the max. time between two subsequent bytes or blocks of a transferred message.
For more information about the timeout, refer to the Remote Control Programming section.
Timeout ETH (in seconds)
Default value: 5, Range: 5...65535
Defines a timeout after which the unit would close the socket connection if there was no
command communication between the controlling unit (PC, PLC etc.) and the unit for the
adjusted time. The timeout is ineffective as long as option “TCP keep-alive” is enabled and
the keep-alive network service is running.
Com Protocols
Enables or disables SCPI or ModBus communication protocols for the unit. The change is
immediately effective after submitting it with ENTER button. Only one of both can be
disabled.
Logging
Default setting: disabled:
Enables/disables the “log to USB stick” feature. Once enabled, you can define the log
interval (multiple steps, 500 ms ... 5 s) and the control method. For more refer to section
6.4.10, “
Saving data to USB Memory Device (Data Logging)
6.4.3.9
HMI / Front Panel Menu
These settings refer exclusively to the front panel controls.
Element
Description
Language
Selection of the display language between German, English (default), Russian or Chinese
Backlight
The choice here is whether the backlight remains permanently on or if it should be
switched off when no input via screen or rotary knob is made for 60 s. As soon as input is
made, the backlight returns automatically. Furthermore, the backlight intensity can be
adjusted here.
HMI Lock
Refer to section 6.7, “
Limits Lock
Refer to section 6.8, “
Key Sound
Activates or deactivates sounds when touching a touch area in the display. This signals that
the action has been accepted.
Alarm Sound
Activates or deactivates the additional acoustic signal of an alarm or user defined event,
which has been set to “Action = ALARM”. See
section 6.6, “Alarms and Monitoring” on
page 87.
Status page
Enables/disables two display related options for the main screen with actual and set
values:
Show meter bar: in U/I/P mode, i.e. resistance mode not activated, a meter bar for 0-
100% actual values of voltage, current and power is shown.
Alternative status page: switches the main screen of the unit with its actual and set
values of voltage, current, power and - if activated - resistance to a simpler display with
only voltage and current, plus status.
Default setting: both disabled