![APS 6RL Series Скачать руководство пользователя страница 57](http://html1.mh-extra.com/html/aps/6rl-series/6rl-series_operation-manual_2956801057.webp)
6RL SERIES OPERATION MANUAL
SECTION 6: FRONT PANEL OPERATION
Entire Contents Copyright
2018 by Adaptive Power Systems, Inc. (APS) • All Rights Reserved • No reproduction without written authorization from APS.
6RL Series Regenerative DC Load Operation Manual
Page 57 of 204
6.2
Touch Screen Display
The graphic touchscreen display is divided into a number of areas. The complete display is
touch sensitive and can be operated by finger or stylus to control the equipment.
In normal operation the left hand side displays output read back values and set values and
the right hand side displays status information:
Note that touch areas may be enabled or disabled:
Black text or symbol = Enabled
Grey text or symbol = Disabled
This applies to all touch areas on the main screen and all menu pages.
6.2.1
Settings
In normal operation, the DC Input values (large numbers) and set values (small numbers) for
voltage, current and power are displayed. Resistance set value of the variable internal
resistance is only displayed when in active resistance mode.
When the DC Input is turned on, the actual regulation mode, CV, CC, CP or CR is displayed
next to the corresponding actual values, as shown in the figure above.
The set values can be adjusted with the rotary knobs next to the display screen or can be
entered directly via the touchscreen. When adjusting with the knobs, pushing the knob will
select the digit to be changed and thus the programming resolution. The set values are
increased by clockwise turning and decreased by anti-clockwise turning.