6RL SERIES OPERATION MANUAL
SECTION 4: TECHNICAL SPECIFICATIONS
Entire Contents Copyright
2018 by Adaptive Power Systems, Inc. (APS) • All Rights Reserved • No reproduction without written authorization from APS.
6RL Series Regenerative DC Load Operation Manual
Page 30 of 204
4.3
6.2kW Models
–
208Vac Input (-2)
6.2 kW
Model
6RL6.-340-80-2
6RL6.-140-250-2
6RL6.-60-500-2
6RL6.-44-750-2
6RL6.-30-1000-2
AC Input/Output
Input/output voltage
208 V, ±10%, L-L
208 V, ±10%, L-L
208 V, ±10%, L-L
208 V, ±10%, L-L
208 V, ±10%, L-L
Input/output connection
L1, L2, L3, PE
L1, L2, L3, PE
L1, L2, L3, PE
L1, L2, L3, PE
L1, L2, L3, PE
Input/output frequency
50/60 Hz ±10%
50/60 Hz ±10%
50/60 Hz ±10%
50/60 Hz ±10%
50/60 Hz ±10%
Input/output fuse (internal)
T16 A
T16 A
T16 A
T16 A
T16 A
Efficiency
(2
≤ 92.5%
≤ 93.5%
≤ 94.5%
≤ 94.5%
≤ 94.5%
DC Input
Max. input voltage UMax
80 V
250 V
500 V
750 V
1000 V
Max. input power PMax
6200 W
6200 W
6200 W
6200 W
6200 W
Max. input current IMax
340 A
140 A
60 A
44 A
30 A
Overvoltage protection range
0...1.1 * UMax
0...1.1 * UMax
0...1.1 * UMax
0...1.1 * UMax
0...1.1 * UMax
Overcurrent protection range
0...1.1 * IMax
0...1.1 * IMax
0...1.1 * IMax
0...1.1 * IMax
0...1.1 * IMax
Overpower protection range
0...1.1 * PMax
0...1.1 * PMax
0...1.1 * PMax
0...1.1 * PMax
0...1.1 * PMax
Max. allowed input voltage
100 V
300 V
600 V
850 V
1200 V
Min. input voltage for IMax
0.73 V
2.3 V
4.6 V
6.9 V
9.2 V
Input capacitance
ca. 1540 μF
ca. 620 μF
ca. 196 μF
ca. 120 μF
ca. 49 μF
Temp.coef. for set values Δ/K
Voltage / current: 100 ppm
Voltage regulation
Adjustment range
0...80 V
0...250 V
0...500 V
0...750 V
0...1000 V
Stability at ΔI
< 0.05% UMax
< 0.05% UMax
< 0.05% UMax
< 0.05% UMax
< 0.05% UMax
Accuracy
(1
(at 23 ± 5°C)
< 0.3% UMax
< 0.3% UMax
< 0.3% UMax
< 0.3% UMax
< 0.3% UMax
Display: Adjustment resolution
See section 6.2.6, “
Available resolutions by voltage models:
Display: Accuracy
(3
≤ 0.2%
Remote sensing compensation
max. 5% UMax
Current regulation
Adjustment range
0...340 A
0...140 A
0...60 A
0...44 A
0...30 A
Stability at ΔU
< 0.15% IMax
< 0.15% IMax
< 0.15% IMax
< 0.15% IMax
< 0.15% IMax
Accuracy
(1
(at 23 ± 5°C)
< 0.4% IMax
< 0.4% IMax
< 0.4% IMax
< 0.4% IMax
< 0.4% IMax
Display: Adjustment resolution
See section 6.2.6, “
Available resolutions by voltage models:
Display: Accuracy
(3
≤ 0.2%
Compensation 10-90% ΔUDC
< 0.6 ms
< 0.6 ms
< 0.6 ms
< 0.6 ms
< 0.6 ms
Power regulation
Adjustment range
0…6200 W
0…6200 W
0…6200 W
0…6200 W
0…6200 W
Stability at ΔI / ΔU
< 0.75% PMax
< 0.75% PMax
< 0.75% PMax
< 0.75% PMax
< 0.75% PMax
Accuracy
(1
(at 23 ± 5°C)
< 1.3% PMax
< 1.5% PMax
< 1.4% PMax
< 1.5% PMax
< 1.4% PMax
Display: Adjustment resolution
See section 6.2.6, “
Available resolutions by voltage models:
Display: Accuracy
(3
≤ 0.2%
Resistance regulation
Adjustment range
0.005…6 Ω
0.04…60 Ω
0.21…240 Ω
0.43…550 Ω
0.83...950 Ω
Accuracy (at 23 ± 5°C)
≤2% of max. resistance ± 0.3% of maximum current
Display: Adjustment resolution
See section 6.2.6, “
Available resolutions by voltage models:
Display: Accuracy
(3
≤0.2%
1.
Related to the nominal values, the accuracy defines the maximum deviation between an adjusted value and the true (actual) value on the DC
input. Example: a 170 A model has min. 0.4% current accuracy, that calculates as 680 mA. When adjusting the current to 80 A, the actual current
on the DC input is allowed to differ by a maximum of 680 mA, which means it may be between 79.32 A and 80.68 A.
2.
Typical value at 100% input voltage and 100% power
3.
The display accuracy adds to the accuracy of the related actual value on the DC input, so the display accuracy will be lower, i.e. the error will be
higher
4.
Includes the accuracy of the displayed actual value
Содержание 6RL Series