![APS 44M04 Скачать руководство пользователя страница 56](http://html1.mh-extra.com/html/aps/44m04/44m04_operation-manual_2956849056.webp)
CHAPTER 4
REMOTE CONTROL PROGRAMMING
Entire Contents Copyright
2014 by Adaptive Power Systems, Inc. (APS) • All Rights Reserved • No reproduction without written authorization from APS.
44M04 LOAD MAINFRAME OPERATIONS MANUAL
Page 56 of 93
44M00
4.6.1
SETTING Commands
RISE
Command Syntax:
[PRESet:] RISE {SP} {NR2} {; | NL}
[PRESet:] RISE ? {; | NL}
Purpose:
Set and read the RISE SLEW-RATE
Description:
1. The definition of the RISE SLEW-RATE is the rate of current change from a LOW
level to a HIGH level when operating in dynamic mode. The settings of RISE and FALL
are completely independent.
2. The RISE command must include a number value otherwise, the command will not be
valid.
3. The least significant number is the fourth digit after the decimal point.
4. Should a value be entered that is higher than what is possible then the 44M04 will
automatically set its maximum value according the load module fitted.
5. The engineering unit is A/us for load modules 41L0630, 41L0660& 41L2512. The
engineering unit is mA/us for load modules 41L5012, 41L0615, 41D & 42D.
FALL
Command Syntax:
[PRESet
:
] FALL {SP} {
; |
NL}
[PRESet
:
] FALL? {
;
| NL}
Purpose:
Set and read the FALL SLEW-RATE
Description:
1. The definition of the FALL SLEW-RATE is the rate of current change from a HIGH
level to a LOW level when operating in dynamic mode. The settings of RISE and FALL
are completely independent.
2. Should a value be entered that is higher than what is possible then the 44M04 will
automatically set its maximum value according the load module fitted.
3. The engineering unit is A/us for load modules 41L0630, 41L0660& 41L2512. The
engineering unit is mA/us for load modules 41L5012, 41L0615, 41D & 42D.
PERI or PERD
Command Syntax:
[PRESet
:
] PERI | PERD
:
HIGH | LOW {SP} {NR2} {
;
| NL}
[PRESet
:
] PERI | PERD
:
HIGH | LOW
?
{
;
| NL}
Purpose:
Set and read the combined TLOW and THIGH of a DYNAMIC waveform
Description: