Dynamic Operation Mode
MODEL
42L0860
42L0824
42L0803
DYNAMIC OPERATION
T high & T low
0.050 - 9.999 / 0.50 - 99.99 / 5.0 - 999.9 / 50 - 9999ms (20 kHz)
Resolution
1 μs / 10 μs / 0.1 ms / 1.0 ms
Accuracy
reso 50 ppm
Slew Rate 4mA-250mA/μs
0.4mA-25mA/μs
1.6mA - 100mA/μs
0.2mA - 12.5mA/μs
40mA-2500mA/μs
4mA-250mA/μs
16mA - 1000mA/μs
2mA - 125mA/μs
Accuracy
± 5% OF SETTING ± 10 μs
Min. Rise Time
24 μs Typical
4.5
Metering
MODEL
42L0860
42L0824
42L0803
METERING
Voltage Range 0 - 6.0V / 0- 81.0V
0 - 6.0V / 0- 81.0V
0 - 6.0V / 0- 81.0V
0 - 6.0V / 0- 81.0V
0 - 6.0V / 0- 81.0V
0 - 6.0V / 0- 81.0V
Resolution 0.1 mV / 1.35 mV
0.1 mV / 1.35 mV
0.1 mV / 1.35 mV
0.1 mV / 1.35 mV
0.1 mV / 1.35 mV
0.1 mV / 1.35 mV
Accuracy
± 0.025% OF (R RANGE)
Current Range 0 - 6.0A / 0 - 60.0A
0 - 0.6A / 0 - 6.0A
0 - 2.4 A / 0 - 24.0 A
0 - 0.3 A / 0 - 3.0 A
Resolution 0.1 mA / 1.0 mA
0.01 mA / 0.1 mA
0.04 mA / 0.4 mA
5 μA / 50 μA
Accuracy
± 0.1% OF (R RANGE)
Power Range
0 - 250.0 W
0 - 50.0 W
0 - 120.0 W
0 - 40.0 W
Resolution
± 0.125% OF (R RANGE)
4.6
Miscellaneous
MODEL
42L0860
42L0824
42L0803
SHORT CIRCUIT
Typical Short Resistance
13.33 mΩ
1.33 mΩ
33.33 mΩ
33.33 mΩ
0.1 Ω
0.1 Ω
Max. Short Current
60 A
6 A
24 A
24 A
3 A
3 A
4.7
AC Input & Cooling
MODEL
41L0630
42L0860
41L2512
41L5012
41L0615
AC INPUT AND COOLING SPECIFICATIONS
AC Power
Supplied by 44M0X Mainframe
Cooling
Supplied by 44M0X Mainframe