3.4
Current Read-back
The load current levels and load status can be set from the front panel of each load module
or over the remote control interface. During testing, load input voltage and load current can
be read back but the current read back will typically display the average current level unless
the dynamic current frequency setting is low enough. An analog current monitor output is
provided to allow capturing of dynamic current on a digital storage scope or data recorder.
3.5
Analog Input Mode
A set of analog inputs is provided at the rear panel of the mainframe to allow analog
programming of load current using a function or arbitrary waveform generator. This allows
any current profile within the performance envelope of the DC load to be used for perform
dynamic load testing beyond the built in dynamic CC mode.
Note:
This mode is supported in Constant Current (CC) and Constant Power (CP) modes
only.
3.6
Product Features
The following key characteristics apply to all 42L Series modules.
•
Fully programmable electronic DC load with flexible configuration and dual range
capabilities.
•
Dual load channels per module for testing multiple output DC supplies
•
Full remote control of all load settings and metering read back.
•
Dual high accuracy and high-resolution 5 digit voltage and current meters with
Go/NoGo determination.
•
Built-in pulse generator includes wide Thigh/Tlow dynamic load range, independent
Rise/Fall load current slew rate control, and High/Low load level.
•
Controllable load current slew rate of load level change,
•
Load ON/OFF switch change and power supply turn ON.
•
Short circuit test with current measure capability.
•
Dedicated over current and over power protection test functions
•
Automatic voltage sensing and external sense.
•
Full protection from over power, over temperature, over voltage, and reverse
polarity.
•
Variable fan speed control for quieter operation