3A SERIES
OPERATION MANUAL
Entire Contents Copyright
2014 by Adaptive Power Systems, Inc. (APS) • All Rights Reserved • No reproduction without written authorization from APS.
3A SERIES AC & DC LOAD OPERATION MANUAL
Page 50 of 56
Note:
Delta connections typically operate at higher voltages than Wye connections as they put
the Line-to-Line voltage across the AC load input. Pay attention to the maximum voltage rating
of the AC load when using them in this application.
Note:
Each phase must be programmed separately as there is no ‘three-phase’ control mode
that will program all loads to the same setting. Alternatively, the remote interface can be used
to do so under program control.
Wiring diagrams for both configurations are shown in the illustrations below.
Figure 9-2: Three Phase Wye Connection
Figure 9-3: Three Phase Delta Connection