background image

DS41035-002 

11

 

LBT0218

 

 

SAFETY STANDARDS AND INSTALLER OBLIGATIONS 

2.1 INFORMATION 

Installers must proceed as follows to conform with safety standards: 

 

wear protective clothing (accident-prevention footwear, goggles, gloves and helmet); 

 

do NOT wear clothing or jewellery that may become trapped (ties, bracelets, necklaces, etc). 

A motorised gate is a machine and as such must be installed in accordance with health and safety standards 
and legislation.  Before installation a risk analysis for the installation site must be performed by professionally 
qualified personnel in accordance with current legislation for motorised gates (refer to EN 12453 and EN 12445).  
In countries outside the EU refer to national regulations and legislation as well as the standards specified. 

 

Only professionally qualifi ed personnel should install the product. 

 

Installation, electrical connections and settings must conform with current legislation. 

 

Carefully read the instruction manual before installation 

 

Incorrect installation may be a source of hazards 

 

Packaging must be disposed of in accordance with current legislation. Do NOT litter the environment 

 

Check that the product and packaging are undamaged before starting installation 

 

Do NOT install the product in areas where there is a risk of explosion. Gas, powders and fl ammable fumes 
represent a health hazard 

 

Check that all safety measures are taken and that people are protected from areas posing a risk of crushing, cutting, 
trapping and any other hazard, in accordance with current legislation for motorised gates 

 

The installation area must be cordoned off to prevent access by unauthorised personnel 

 

Protection devices must be installed following risk analysis of the site. Check that the protection devices are marked 
and that they function in accordance with current legislation 

 

The data required by applicable legislation must be clearly visible on the installation 

 

Check that the mains power available is compatible with the data on the identifi cation plate before connecting the 
operator to the mains power supply. A suitable differential overload switch must be installed upstream of the 
operator 

 

The manufacturer of the operator declines all responsibility if components are used which are incompatible with 
correct and safe use. 

 

The installer must provide the user with all the information need to operate the device with particular attention given 
to manual operation in the event of an emergency and any residual risks. 

 

2.2 

WARNINGS FOR THE USER 

 

The instructions and warnings given below are a vital and integral part of the product. The instructions and warnings 
must be given to the user and then read carefully because they include important warnings for use and 
maintenance. The instructions must be kept and given to all future users. 

 

The operator must be used exclusively for the purpose for which it is designed. All improper use is forbidden and 
hazardous. 

 

Keep away from moving mechanical parts. Keep away from the operating range of the device during operation. Do 
not try to obstruct the movement of the device as such action may be hazardous. 

 

Keep children away from the operating range of the device at all times. 

 

Keep remote control and other control units in a safe place to prevent use by children or unauthorised people. 

 

In the event of any faults disconnect the operator from the mains power supply using the main switch. Do not try to 
repair the main unit. Contact the installer or other specialist assistance centre. Failure to follow these instructions 
may result in hazardous situations. 

 

All maintenance, including cleaning, must be performed by qualifi ed personnel. 

 

Follow the manufacturer’s instructions and refer to specialist personnel to perform routine maintenance, particularly 
verification of correct functioning of protection devices, to ensure correct and efficient functioning of the operator. 

 

All repairs and maintenance must be recorded on the maintenance record and then made available to the user. 

 

Содержание 41035/001

Страница 1: ...llantrieb f r Fl geltore AP350 41035 001 41035 002 Istruzioni di installazione meccanica Utilizzo e Manutenzione Mechanical installation Use and Maintenance instructions Notice d installation m caniqu...

Страница 2: ...scrupuleusement les informations fournies Toutes les donn es ont t r dig es et contr l es avec le plus grand soin Nous n assumons aucune responsabilit en cas d erreurs ventuelles ou d omissions Nous n...

Страница 3: ...4 2 NORME DI SICUREZZA E OBBLIGHI DELL INSTALLATORE 5 2 1 INFORMAZIONI 5 2 2 AVVERTENZE PER L UTILIZZATORE 5 3 INSTALLAZIONE 6 3 1 FISSAGGIO ATTUATORE AP350 6 4 SCHEMA IMPIANTO 7 5 DATI TECNICI 7 6 MA...

Страница 4: ...e lesioni morte o rischi a lungo termine per la salute delle persone e per l ambiente Le indicazioni precedute da questo simbolo contengono procedure o pratiche che se non eseguite correttamente posso...

Страница 5: ...abili Prima di collegarsi alla linea di alimentazione verifi care che la potenza disponibile sia coerente con i dati di targa Verificare che a monte dell installazione sia presente un interruttore mag...

Страница 6: ...tale in bolla rispetto al proprio asse Fig A Fissare il motoriduttore alla piastra grande 1 con Il perno e grano in dotazione Estendere completamente il tubo inox 3 fino alla fine della corsa dopo di...

Страница 7: ...llo stelo 400 mm Lunghezza max anta 2 3 4 m Peso max anta 350 Kg Grado di protezione IP 44 Protezione termica 150 Cicli ora 18 Temperatura di funzionamento 20 C 70 C Tipo lubrificante permanente Conde...

Страница 8: ...o dell apparecchiatura Manutenzione straordinaria se dovessero rendersi necessari interventi importanti sull apparecchiatura si raccomanda le rimozione della stessa per consentire la riparazione in la...

Страница 9: ...N THIS MANUAL 10 2 SAFETY STANDARDS AND INSTALLER OBLIGATIONS 11 2 1 INFORMAtION 11 2 2 WARNINGS FOR THE USER 11 3 INSTALLATION 12 3 1 AP350 OPERATOR MOUNTING 12 4 SYSTEM DIAGRAM 13 5 TECHNICAL DATA 1...

Страница 10: ...y and which could create a long term health and environmental hazard This symbol is used to mark information instructions and procedures which if ignored can cause serious damage to the machine or to...

Страница 11: ...n the installation Check that the mains power available is compatible with the data on the identifi cation plate before connecting the operator to the mains power supply A suitable differential overlo...

Страница 12: ...der perfectly horizontal check with a sprit level and with respect to Its axis Fig A Fix the gear motor to the large plate 1 using the pin and grub screw supplied AP350 OPERATOR MOUNTING Completely ex...

Страница 13: ...e 400 mm Maximum lenght per leaf 2 3 4 m Maximum weight per leaf 350 Kg Housing protection IP 44 Termic Protection 150 Cycles h 18 Operating temperature 20 C 70 C Lubrification permanent grease Capaci...

Страница 14: ...ment extraordinary maintenance if may be necessary major interventions on the equipment it is recommended that the removal of the same to allow the repair in the laboratory by technicians on the manuf...

Страница 15: ...ORMES DE S CURIT ET OBLIGATIONS DE L INSTALLATEUR 17 2 1 INFORMATIONS 17 2 2 MISES EN GARDE POUR L UTILISATEUR 17 3 INSTALLATION 18 3 1 FIXATION OP RATEUR AP350 18 4 SCH MA DU SYST ME 19 5 DONN ES TEC...

Страница 16: ...ire mortelles ou des risques long terme pour la sant des personnes et pour l environnement Les indications pr c d es de ce symbole mentionnent des proc dures ou des pratiques qui si elles ne sont pas...

Страница 17: ...le branchement de la ligne d alimentation v rifi er que la puissance disponible est conforme aux donne nominales V rifi er la pr sence d un disjoncteur magn tothermique diff rentiel appropri en amont...

Страница 18: ...tableau et positionner le piston parfaitement l horizontal de niveau par rapport son propre axe Fig A Fixer le motor ducteur la grande plaque 1 avec le pivot et le grain fournis Tirer compl tement le...

Страница 19: ...ngueur max vantail 2 3 4 m Poids max vantail 350 Kg Degr de protection IP 44 Protection termique 150 Cylces h 18 T mperature d emploi 20 C 70 C Lubrification fat permanent Condensateur 8 F Poids moteu...

Страница 20: ...t tre n cessaire interventions majeures sur le mat riel il est recommand que la suppression de la m me pour permettre la r paration dans le laboratoire par des techniciens sur le fabricant ou autoris...

Страница 21: ...NORMAS DE SEGURIDAD Y OBLIGACIONES DEL INSTALADOR 23 2 1 INFORMACI N 23 2 2 ADVERTENCIA PARA EL USUARIO 23 3 INSTALACI N 24 3 1 ACTUADOR MONTAJE AP350 24 4 ESQUEMA DEL SISTEMA 25 5 DATOS T CNICOS 25...

Страница 22: ...sgos a largo plazo para la salud de las personas y para el ambiente Las indicaciones que est n precedidas por este s mbolo contienen procedimientos o pr cticas que si no se ejecutan correctamente pued...

Страница 23: ...con los datos de la placa Verificar que l nea arriba de la instalaci n exista un interruptor magnetot rmico diferencial adecuado El fabricante de la motorizaci n declina toda responsabilidad si se ut...

Страница 24: ...amente horizontal nivelado con respecto a su eje Fig A Fijar el motoreductor a la placa grande 1 con el perno y el tornillo prisionero entregado Extender completamente el tubo inoxidable 3 hasta el fi...

Страница 25: ...rgura max de la hoia 2 3 4 m Peso max de la hoja 350 Kg Grado de proteccion IP 44 Proteccion termica 150 Ciclos h 18 Temperatura de trabajo 20 C 70 C Tipo de lubricante grasa permanente Condensador 8...

Страница 26: ...e ser necesario intervenciones importantes sobre el equipo se recomienda que la supresi n de la misma para permitir la reparaci n en el laboratorio por t cnicos en el fabricante o autorizados El fabri...

Страница 27: ...2 SICHERHEITSNORMEN UND PFLICHTEN DES INSTALLATEURS 29 2 1 INFORMATIONEN 29 2 2 WARNHINWEISE F R DEN ANWENDER 29 3 INSTALLATION 30 3 1 BEFESTIGUNG DES STELLANTRIEBS AP350 30 4 ANLAGENPLAN 31 5 TECHNIS...

Страница 28: ...ngfristigen Risiken f r die Gesundheit von Mensch und Umwelt f hren k nnen Die Angaben denen dieses Symbol vorsteht enthalten Verfahren oder Praktiken die falls nicht ordnungsgem durchgef hrt zu schwe...

Страница 29: ...sichtbar angegeben sein Vor dem Anschluss an das Stromnetz ist zu berpr fen dass die zur Verf gung stehende Leistung mit den Angaben des Datenschilds bereinstimmt Pr fen dass der Anlage ein angemesse...

Страница 30: ...zu seiner eigenen Achse anordnen Abb A Den Getriebemotor mit dem Bolzen und den Stift aus dem Lieferumfang an der gro en Platte 1 befestigen Das Edelstahlrohr 3 vollst ndig bis auf seinen Endanschlag...

Страница 31: ...Schafthub 400 mm Max Torfl gell nge 2 3 4 m Max Torfl gelgewicht 350 Kg Schutzart IP 44 W rmeschutz 150 Zyklen Stunde 18 Betriebstemperatur 20 C 70 C Schmiermitteltyp Dauerschmiermittel Kondensator 8...

Страница 32: ...g zu berpr fen Au erordentliche Instandhaltung sollten sich wichtige Eingriffe an der Vorrichtung als erforderlich erweisen wird deren Abbau empfohlen um eine Reparatur in der Werkstatt durch Technike...

Отзывы: