background image

3

2

Your humidifier is controlled by either an Automatic Digital
Humidifier Control, or a Manual Humidifier Control. 

The Automatic Digital Humidifier Control offers two modes of
operation, Automatic or Manual. When in the Automatic Mode,
this system offers the following benefits:

• 

You will receive the optimum amount of humidity so that
your home and its furnishings are protected from the
damaging effects of excess condensation or low
humidity during the heating season.

The Control

automatically adjusts your home’s RH based on the outdoor
temperature, increasing the time maximum comfort is
maintained

• 

Simple operation with few adjustments.

The Control

eliminates the need to manually adjust the control when
outdoor temperature changes. It also eliminates the need to turn
the dial setting to “OFF” during the summer season. 

YOUR HUMIDIFIER

OPERATING INSTRUCTIONS

Blower Activation

Digital Humidifier Control Indicator Lights 

Set the “Blower Activation Switch” to “ON” to allow the
humidifier control to activate the HVAC fan for maximum
humidification. For this setting the Models 500, 600 and 700 must
be connected to hot water. 

If the HVAC system has been idle for one hour, the humidifier
control will activate the HVAC system fan to sample the air for 3
minutes. If the RH is lower than the set point, the humidifier
control will activate the humidifier and keep the fan running. The
humidifier will continue to operate for 2 hours or until the
humidification set point is reached. 

If the RH set point has not been reached by the end of a call for
heat, the control will continue to operate the humidifier and the
HVAC fan until the humidification set point is reached or 2 hours
have elapsed.

When the “Blower Activation Switch” is in the “OFF“ position, the
humidifier control will only operate the humidifier if humidity is
required and the HVAC system fan is operating or the HVAC
system is producing heat.

NOTE:

If used in conjunction with an Aprilaire 8570

Communicating Thermostat, and the blower activation feature is
desired, DO NOT wire the A B communication terminals.

Call Dealer for Service:

The red light indicates that the

humidifier is not operating normally and that service is required.

Change Water Panel:

The yellow light indicates that it is time

to change the Water Panel in the humidifier. (Model 60 only. The
Model 62 is used for steam applications that do not require this
feature.)

Humidifier On:

The green light indicates that the humidifier is

operating normally.

Содержание 60

Страница 1: ...Automatic Digital and Manual Humidifier Control Models 60 62 4655 Operating Instructions INSTALLER Please leave this Operation Manual with the homeowner ...

Страница 2: ...C system has been idle for one hour the humidifier control will activate the HVAC system fan to sample the air for 3 minutes If the RH is lower than the set point the humidifier control will activate the humidifier and keep the fan running The humidifier will continue to operate for 2 hours or until the humidification set point is reached If the RH set point has not been reached by the end of a ca...

Страница 3: ... needs to be set initially to match your home s condition Please follow these steps when adjusting your control refer to Figure A 1 Turn the dial setting knob to 5 which is within the normal range During the next 24 48 hours it may be necessary to adjust the dial for more or less humidity depending on your personal comfort and home s requirements Refer to TABLE 3 Operation Guide 2 During the colde...

Страница 4: ...romise between humidity levels that would be most desirable for comfort and humidity levels that are suitable for protection of your home and to avoid condensation on your windows For example a wintertime indoor humidity of 50 may be considered ideal for comfort but unfortunately it probably would result in condensation which can cause damage to your home Observing the recommended humidity levels ...

Страница 5: ...cked even if there is no call for humidity See Check the Humidifier Operation on page 12 ADDITIONAL INFORMATION Your humidifier is a precision system that will accurately maintain the humidity in your home For every 2 F change in outdoor temperature the Digital Humidifier Control will automatically adjust the indoor RH by 1 The Digital Humidifier Control will accurately control the humidity in you...

Страница 6: ...error code on the display E1 E2 E3 or E4 and call your heating and air conditioning dealer Model 60 only Yellow Change Water Panel light flashes Figure A Refer to the Humidifier Owner s manual for instructions on changing the Water Panel or call your heating and air conditioning dealer for service After the Water Panel is replaced turn the Control knob to the Test Reset position until the green Hu...

Страница 7: ...on after 1 minute the display will flash the software revision level e g r1 MANUAL HUMIDIFIER CONTROL Set the knob to the highest setting make sure that the water saddle valve is open and that there is electricity to the humidifier The HVAC system must be operating for the humidifier to function Confirm that the solenoid valve is energized and water is flowing into the humidifier Return control kn...

Страница 8: ......

Страница 9: ...P O Box 1467 Madison WI 53701 1467 Phone 800 334 6011 Fax 608 257 4357 www aprilaire com 10008993 8 13 B2205132B Printed in U S A 2013 Aprilaire A division of Research Products Corporation ...

Отзывы: