background image

- 3 -

There are some homes where drain facilities are not accessible

or  available.  For  these  situations,  or  where  high  water 
hardness  is  not  a  problem,  the  newest  Aprilaire,  Model  400,  is
designed to satisfy these applications.

Capacity  is  high  because  an  average-size  home  (10,000  cu.  ft.)

requires  the  addition  of  approximately  9  gallons  of  water 
per day to maintain 35% relative humidity when the outside temper-
ature is 20°. The smallest Aprilaire Humidifier under most operating
conditions,  has  this  humidifying  capacity. Trouble-free  perfor-
mance  and  minimum  maintenance  are  assured  by  the  design  fea-
tures of the Aprilaire Humidifier. All unit housing parts that come in
contact  with  water  are non-metal and  will  never  rust  or  corrode.
Neither heat nor water will affect them under normal operating con-
ditions.

The  Water  Panel  evaporator,  designed  especially  for  uniform,

high  evaporation,  and  the  Scale  Control  Insert  also  efficiently  traps
mineral  deposits  which  are  often  the  cause  of  damage  to  working
parts  in  ordinary  humidifiers.  No  “white  dust”  can  be  distributed
throughout  the  living  quarters.  The  Water  Panel  evaporator  is  the
heart  of  the  unit  and  must  be  in  good  condition  to  assure  high
capacity trouble-free performance. It should be changed once a year
with  the  exception  of  the  Model  400  where  it  should  be  changed
twice a season.

The  granular  coating  in  the  bottom  of  the  distribution  tray  is

designed  to  provide  equal  distribution  of  the  water  to  each  of  the
openings assuring an even flow of water over the Water Panel evap-
orator.  Do  not  clean  the  mineral  scale  off  the  bottom  of  the  water
distribution  tray  at  the  end  of  the  humidification  season.  The  scale
itself provides an excellent track for the water to follow. This is actu-
ally what we try to simulate with the synthetic coating in the bottom
of the tray. If the coating is removed, it is not necessary to purchase a
new  distribution  tray  or  upper  housing.  You  can  accomplish  the
same uniform performance by applying a small amount of liquid dish-
washing detergent over the entire inside surface of the water distribu-
tion tray. This will allow the water to flow evenly through each of the
openings,  provided,  of  course,  the  unit  is  level  in  order  to  achieve
maximum capacity.

There  are  many  humidifiers  on  the  market.  They  all  add 

moisture . . . with varying degrees of efficiency. None, however, can
provide  the  features,  design,  and  performance  incorporated  into
your Aprilaire Humidifier.

Содержание 400 Series

Страница 1: ... Operating Instructions Automatic Mode 4 Manual Mode 6 Effect of Water Characteristics 8 Annual Maintenance 9 Annual Summer Shutdown 9 Periodic Preventative Maintenance 9 MAINTENANCE INSTRUCTIONS Models 400 11 Model 600 12 Model 700 13 Limited Warranty 14 Replacement Record 18 19 AUTOMATIC HUMIDIFIER The Best Cure For Dryness FOR MODELS 400 600 700 OWNER S MANUAL ...

Страница 2: ... to add your name to our growing list of customers With this purchase you have invested in the highest quality equipment currently available Research Products Corporation is the largest manufacturer of whole house humidifiers air cleaners and fresh air exchangers and is a recognized leader in the heating and air conditioning industry today Please be assured that in addition to product quality we a...

Страница 3: ...ifier is installed to operate in conjunction with the furnace blower motor When the Aprilaire Humidifier Control calls for humidity and the blower motor is operating water flows to the distribution tray located at the top of the unit The water is uni formly distributed across the width of the tray and through a scien tifically designed system of outlets It flows by gravity over the Water Panel eva...

Страница 4: ...s the heart of the unit and must be in good condition to assure high capacity trouble free performance It should be changed once a year with the exception of the Model 400 where it should be changed twice a season The granular coating in the bottom of the distribution tray is designed to provide equal distribution of the water to each of the openings assuring an even flow of water over the Water P...

Страница 5: ...ng on your personal comfort and home s requirements Refer to the Operation Guide Table 1 2 During the coldest portion of the first heating season minor 4 Table 1 Operation Guide Condition Solution Condensation on windows Reduce the setting on the control dial by 1 increment Lack of humidity Increase the setting on the control dial by 1 increment Humidifier does not operate Turn dial to Test Make c...

Страница 6: ... on Next slowly turn the dial counter clockwise until you hear the solenoid valve click off At this point make note of the dial setting 4 Locate your dial setting on Table 2 Follow the dial setting to the right until it intersects with the current outdoor temperature This is the relative humidity in your home under existing conditions 5 Return the thermostat and the control to their original setti...

Страница 7: ... average home These settings represent a compromise between RH levels that would be most desirable for comfort reasons and humidity levels that are suitable for protection of your home and to avoid condensation on your windows For example a wintertime indoor RH of 50 may be considered ideal but unfortu nately it probably would result in damage to your home Observance of the recommended RH levels o...

Страница 8: ...coming out at the drain reduce the humidistat setting to the recommended inside relative humidity depending on the outside temperature DO NOT LEAVE IN TEST MODE AS HUMIDIFIER WILL NOT OPERATE Follow the suggested settings prior to a drop in the outside temperature MANUAL MODE Figure B tion of too high relative humidi ties This same condensation can take place in other areas in your home with the p...

Страница 9: ...r humidifier will operate effectively using either hot cold hard or mechanically softened water Whether to use available tap water even though it may be quite hard or chemically softened water is a common concern to homeowners when installing a humidifier Water used in homes contains varying amounts of minerals The residue remaining as a result of hard water evaporation is primarily calcium and ma...

Страница 10: ...Genuine Aprilaire Water Panels to maintain performance V ANNUAL SUMMER SHUTDOWN 1 For Models 400 and 600 close the bypassdamper With the use of the small damper handle 2 Shut off the water supply to the humidifier by closing the sad dle valve Humidifier Control There is no adjustment to the Humidifier Control required for summer shutdown Applies to both Automatic and Manual Mode VI PERIODIC PREVEN...

Страница 11: ...ervice Department Part No 4004 5 Replace the in line strainer and reconnect the inlet water line Double Wrench To Prevent Leaking 6 Disconnect the water line at the outlet compression nut 7 Remove the orifice from the copper or plastic tube and make sure this small opening is unplugged 8 Replace the orifice and reconnect the outlet water line Double Wrench To Prevent Leaking 9 Turn on water supply...

Страница 12: ...sert float chamber and dispose of the water panel Inspect the overflow hose 9 to make sure it is open 7 Remove the float cover 10 and inspect the floats 11 and float chamber for mineral build up Remove deposits as needed from floats float chamber and scale control insert Wash the parts with a disinfecting cleaner Reassemble the floats and float cover Make sure stems of both floats extend through o...

Страница 13: ...col ored spot up and snap the black distribution tray back into place 7 Re install the Water Panel evaporator assembly into the unit by fitting its drain tube into the round receptacle at the base of the unit Push the assembly in at the top against the beveled tabs that will hold it in place Push the end of the feed tube back firmly into the distribution tray and replace the front cover 8 Remove t...

Страница 14: ...to the scale control insert with the red colored spot up and snap the black distribution tray 4 back into place 7 Re install the water panel evaporator assembly 3 into the base assembly 2 Push it in at the top between the retaining ribs that hold the assembly in place in a vertical posi tion 8 Remove the drain hose 8 from the bottom of the unit Bend and flex it to loosen the internal calcium depos...

Страница 15: ...CTS IN WORKMANSHIP OR MATERIALS FURNISHED BY YOUR INSTALLER AS CONTRASTED TO DEFECTS IN THE HUMIDIFIER ITSELF IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE SHALL BE LIMITED IN DURATION TO THE AFORESAID ONE YEAR PERIOD RESEARCH PRODUCTS CORPORATION S LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES OTHER THAN DAMAGES FOR PERSONAL INJURIES RESULTING FROM ANY BREACH OF TH...

Страница 16: ...utomatic humidifier Aprilaire High Efficiency Air Cleaners Nobody Makes Clean Air Easier Delivers the cleanest healthiest air ever available from a whole house air cleaner THE BEST IN INDOOR AIR COMFORT Aprilaire Zone Control Systems Custom Comfort Throughout Your Home The most reliable way to achieve temperature control in every area of your home Aprilaire Energy Recovery Ventilator Only The Fres...

Страница 17: ...SERVICE AND WATER PANEL REPLACEMENT RECORD Date Dealer Name ...

Страница 18: ...SERVICE AND WATER PANEL REPLACEMENT RECORD Date Dealer Name ...

Страница 19: ...DP 10005406 Printed in U S A P O BOX 1467 MADISON WI 53701 1467 Products For Better Indoor Air Quality ...

Отзывы: