INSTALLATION
MANUAL
ALL-IN-ONE AIR SOURCE
WATER HEAT PUMP
WITH A 260L TANK
OPERATION
MAINTENANCE
WARRANTY
APHP-R290-260
Страница 1: ...INSTALLATION MANUAL ALL IN ONE AIR SOURCE WATER HEAT PUMP WITH A 260L TANK INSTALLATION OPERATION MAINTENANCE WARRANTY APHP R290 260 ...
Страница 2: ...at no air pockets remain Once water begins running out of the hot water tap the system is completely bled and you can then turn the tap off Please bleed air out of PTRV as well E Turning the system on a Remove the controller cover by simply loosening hand screws b Unlock the screen by pressing the POWER button once c Press and hold the POWER button for 3 seconds until the SUN symbol flashes d Chan...
Страница 3: ..._________________________________ 21 6 2 Illustrations on how to use the controller___________________________________________ 23 6 3 Set Water Tank Temperature_____________________________________________________ 24 6 4 Menu interface________________________________________________________________ 24 6 4 1 Timer timing_________________________________________________________________ 24 6 4 2 Wi f...
Страница 4: ...Construction d AS NZS AS 3498 2009 Water heaters and hot water storage tanks e The power cord chosen must be compliant with AS NZS 3191 and the nominal cross sectional area should be 1 5 mm2 or more and should handle at least 20A 2 core and earth 4 Removing the access cover or other water heating system components may expose 240V wiring therefore these components MUST only be removed by an authori...
Страница 5: ...ay void the products warranty This appliance uses R290 propane refrigerant which is a classified as a flammable gas class 3 according to AS 1677 and must be serviced by a refrigeration mechanic with an appropriate Australian refrigerant handling license If the refrigerant leaks near an external ignition source there is a possibility of ignition DO NOT store chemicals or flammable materials near th...
Страница 6: ... operation of the heat pump Corrosion The process that involves deteriorating material due to oxidation Cylinder Refers to the tank cylinder ECV Expansion control valve This is installed on the cold mains line to relieve excess pressure Electrical Conductivity Amount of dissolved material in water which relates to its ability to conduct electrical current through it Hardness Water that is high in ...
Страница 7: ...t Specifications Overview 3 SECTION 3 1 Key parts in the all in one heat pump Figure 1 All in one heat pump key parts 1 3 2 4 5 6 7 1 Water Tank 2 Heat Pump System 3 Upper Cover 4 Front Decorative Board 5 Controller Fixing Plate 6 Controller 7 Protective Cover ...
Страница 8: ...0 c Water tank per AS 5125 6 74 Electric Element Rated Power Current Watts Amp 1800 8 Storage Tank Capacity L 260 Water Pipe Size Inch G3 4 Waterproof Level IPX4 Tank PTRV Rating KPA 850 Noise DB 43 Net Weight KG 118 Installation Location OUTDOOR Operational Ambient Range C 7 to 43C Compressor GMCC Toshiba R290 Evaporator Copper tube and aluminum fin type Fan Axial type Tank Enamel Carbon Steel He...
Страница 9: ... comes with a sacrificial anode as well as the electric anode The electric anode will reduce the frequency of magnesium rod anode replacement 3 3 Storage tank 3 SECTION Figure 2 All in one heat pump and tank dimensions and port sensor locations Cold Water Inlet Anode Electric Heating Element Electric Anode Thermal Sensor Hot Water Outlet Safety Relief Valve Condensate Water Inlet Handle 102 620mm ...
Страница 10: ...er can be used for the following purposes 1 To monitor the systems operational parameters such as tank temperature power usage ambient data etc 2 To change or adjusting the operation mode The system has 4 operational modes The default mode is ECO which relies on the heat pump for the supply of hot water exclusively precludes input energy from the electric element THE CONTROLLER IS NOT IP RATED SO ...
Страница 11: ...se lines wrap around heat exchanger and the cooler refrigerant goes back to the top section of the heat pump and the heating cycle repeats Bottom Section The bottom section of the heat pump is where the heat transfer occurs via the coils which wrap around the storage tank It must be noted that there is no direct contact between the water and refrigerant The refrigerant receives heat from air and s...
Страница 12: ...In One Air Sourced Water Heat Pump 10 HOW THE SYSTEM WORKS CONT 4 SECTION Figure 5 Heat Pump Components and refrigerant cycle T2 T2 T4 T1 Compressor High Pressure Switch 4 Way Valve Dryer 1 Way Valve EEV Evaporator ...
Страница 13: ...tio of no more than 30 Transporting or storing the unit in a horizontal position will void the warranty The system should always be transported in its packaging Any marks caused by inappropriate handling are not deemed as defects and are not covered under warranty 5 1 Delivery Installation 5 SECTION Do NOT tilt beyond 30 Pallet for transport only ...
Страница 14: ...s where falling debris such as leaves is excessive Avoid placing the system in locations with multiple walls or structures i e consult with Figure 7 and Figure 8 Always maintain the optimum perimeter from all structures see below If installed under fixtures or home eves there must be a minimum 300 mm clearance between the top of the unit 600 mm on the right hand side of the system when facing unit...
Страница 15: ... base should be at least 50 mm thick the minimum dimension of the concrete base should be 600 mm x 600 mm Please ensure that all four feet are supported on the concrete base being used failure to do so may void the products warranty Proper drainage should be observed for any overflow in accordance with AS NZS 3500 2 When installed the unit must be completely vertical and level as to ensure that an...
Страница 16: ...ilure to do so may void the warranty The process of heat extraction from the atmosphere through evaporator coils results in the production of water in the form of condensation To collect this water by product a Condensate Tray is located on top of the water storage tank Overflow from this tray runs out through the Condensate Drain item 3 in figure 8 The systems condensate drain is connected by a 1...
Страница 17: ... point remaining open to the atmosphere Pressure reducing valve It is mandatory to be installed in accordance with AS 3500 This must be rated 500 kPa on the cold inlet to the tank Tempering valve It is mandatory to be installed in accordance with AS 3500 The typical set point is 50 C Expansion control valve The local requirements must be checked with the installer to see if this is required as par...
Страница 18: ...Apricus All In One Air Sourced Water Heat Pump 16 5 SECTION INSTALLATION CONT Figure 9 Plumbing diagram of system left and side view ...
Страница 19: ...e time ensure at least one hot water tap is open inside the house While the system begins filling with water you will hear air being expelled from the open hot water tap This is called bleeding the system and it ensures that no air pockets remain Once water begins running out of the hot water tap the system is completely bled and you can then turn the tap off Always ensure that the tank is complet...
Страница 20: ...e the responsibility of the trained installer The key specifications are summarised in the Table below 5 5 Electric Wiring The electrical connections must be completed by a qualified and trained professional and in accordance with the local and national regulations AS 3000 Table 1 Key wiring specifications INSTALLATION CONT Power supply Cable Size mm2 Protection Device RCBO Type B Earth Leakage 22...
Страница 21: ...stead of using a 3 pin plug hard wiring of system to a 20A isolator switch is highly recommended Before any work can commence ensure that the heater is isolated from the power supply at the switchboard If the supply cord is damaged it must be replaced by either the manufacturer a service agent or similarly qualified person to avoid a hazard 1 Electrical Cabel 2 Electrical Access 1 2 620mm 1810 1 E...
Страница 22: ...Apricus All In One Air Sourced Water Heat Pump 20 5 SECTION 5 5 2 Wiring diagram Diagram below shows the overall internal wiring of heat pump system INSTALLATION CONT ...
Страница 23: ...n with the in built electric element The table below highlights the different operating modes of the unit The system comes with four operational modes The default operational mode is the ECO mode and the key difference between the different operating parameters are explained in the Table below and are as per follow AUTO The system maximum temperature at the sensor level is set at 60 C If heat pump...
Страница 24: ...s above will only be activated during the selected timetable highlighted above CONTROLLER OPERATIONAL MODES CONT Table 2 The settings of 4 operational modes the factory default is ECO mode and the end user can change among the modes using the controller The temperature in this table is the measured temperature by tank sensor temperature and this is marked as Thermal Sensor on the tank drawings Mod...
Страница 25: ...con disappears 8 4 way valve When the defrost mode is activated the icon appears When the defrost mode is deactivated the icon disappears 9 Fan when the fan is running the icon appears When the fan is not running the icon disappears 10 Solar Photovoltaic When PV mode is activated the icon appears When it is deactivated the icon disappears 11 WIFI When WIFI is connected the icon appears When WIFI i...
Страница 26: ...is Invalid in other words on and off times cannot be the same After setting is completed tap ON OFF button to enable disable the timer 6 3 Set Water Tank Temperature Tap SET TEMP on the main interface and then tap and to adjust or decrease the set tank temperature and then tap OK to confirm the setting 6 SECTION CONTROLLER OPERATIONAL MODES CONT 6 4 Menu interface The relevant items for the instal...
Страница 27: ...sername and password are decrypted by the UDP packet and the WIFI username and password received by the hardware configuration are sent to the designated WIFI AP AP mode APP configures the mobile phone to connect to the intelligent hardware AP of the WIFI chip The mobile phone and the WIFI chip directly establish communication and the WIFI username and the WIFI password to be configured are sent t...
Страница 28: ...urn the page before 6 4 3 Clock settings Click CLOCK to enter the real time clock setting 6 4 4 Brightness settings Click BRIGHTNESS to set the screen brightness 6 5 Query interface Operating Temperature Query Tap the TEMPERATURE key to enter the temperature query interface displaying the real time temperature of each temperature point Temp Scale Clock Brightness Reset Para User Para Factory Para ...
Страница 29: ...current power and accumulated power consumption you can reset and clear the accumulated power consumption password 1234 History Fault Inquiry Tap the FAULT INFO key to view the history of faults you can query the recent history of faults and the corresponding occurrence time Tap CLEAR RECORD key to clear the fault record Software Hardware Version Query ...
Страница 30: ...ers such as Power usage Accumulative but this can also be reset Tank temperature Ambient temperature Access the monitoring data by clicking on the SETTING ICON on the bottom right of the app Adjust the mode of operation and set the tank temperature AUTO ECO BOOST ELE To change modes click on the mode icon which is the middle icon at the bottom of the main screen Using the time function Access this...
Страница 31: ...OM AU 29 6 SECTION CONTROLLER OPERATIONAL MODES CONT The timer function is the last item on the settings page The timer function can set up to 3 operational windows and there are additional settings available such as selecting the day of the week ...
Страница 32: ... exterior of the tank and wall for air circulation and servicing The drain water is not blocked and can be drained with gravity All exposed piping is fully insulated The system is connected to a dedicated 20A circuit The cold water pressure is 200 kPa or greater The appliance is installed in accordance with national wiring regulations Ventilation openings are clear of obstruction Mechanical connec...
Страница 33: ...llow the steps below 7 SECTION 1 Download the HOT WATER HUB or HOTWATERHUB App on Appstore Google Play This must be installed on the owner s mobile phone THIS APP IS FREE 2 After the APP is downloaded register your account by email when you first login 3 Make sure the mobile phone to be connected with the WIFI Select Auto Scan also touch Configuring Wi Fi to input the WiFi name and password Now th...
Страница 34: ... the controller Touch the button Set touch the button WiFi touch the button EZ Mode to activate the WIFI connection During the configuration the icon will be flashing 5 Once the connection is successful you will see following pages on the controller and APP 6 See following homepage on App ...
Страница 35: ...ame as fault 3 5 Hot Water Tank Temp Fault Same as fault 3 6 Exhaust Temp Fault Same as fault 3 7 Return Air Temperature Fault Same as fault 3 Table 3 Error code display and possible causes solutions Table 4 Some common issues and initial troubleshooting guidance ISSUE POSSIBLE REASONS APPROACH The outlet water is cold and or the screen is dark The plug is not plugged properly The temperature cont...
Страница 36: ... 1 Warranty periods The system is supplied with a six year warranty labor is covered for the first year after installation Eligibility requirements to make a claim The person s making the claim must be the product owner or have consent to act on behalf of the owner The person s making the claim must contact Solar thermal Australia as soon as they notice any defect s without excessive delay and the...
Страница 37: ...allation work conducted by the installer of the hot water system or component s in domestic use 10 1 This Warranty only applies to the Solar thermal Australia domestic hot water system and its components or component s in domestic use and does not cover any plumbing or electrical associated parts including but not limited to any parts supplied by any person installing the Solar thermal Australia D...
Страница 38: ...sed either directly or indirectly by leakage from the heat pump hot water system or any other faults b Warranty does not cover any faults that may arise from connecting to a water source that is unfiltered such as dams bores rivers etc 21 1 The warranty will be rendered void in the following circumstances a Failure due to misuse natural disasters Acts of God accidental damage installation by an in...
Страница 39: ...rvice Solar thermal Australia heat pump hot water system 3 All Solar thermal Australia heat pump hot water system must be installed in accordance with Manufacturer s Installation Instructions and in Accordance with local regulations municipal building codes and current AS NZS 3000 AS NZS 3500 AS 3498 and AS NZS 5601 4 If the Solar thermal Australia heat pump hot water system has not been installed...
Страница 40: ...or ppm Electrical Conductivity 850 µS cm Chloride 300 mg L or ppm pH Level Min 6 5 to Max 8 5 Magnesium 10 mg L or ppm Sodium 150 mg L or ppm Iron 1mg L or ppm Alkalinity as CaCO3 200 mg L or ppm Dissolved free CO2 25 mg L or ppm Table 5 Water quality requirement for Solar thermal Australia Hot Water Heat Pump Installation 10 SECTION ...
Страница 41: ...llation ___________ __________ 20__________ Suppliers Name ____________________________________________________________________________ 10 3 Warranty Registration Lodge a claim For all warranty issues please call Solar thermal Australia on 1300 277 428 or email warranty apricus com au Provide full product owner s contact details name of owner address of installation site contact number s proof of ...
Страница 42: ...nvironmentally friendly heating or cooling tailored to Australian requirements Through our commitment to product innovation and next generation technology we truly believe we have designed a pool heat pump system that is one of the most energy efficient and flexible solutions available in Australia today Our people are here for you We have high quality resellers all around Australia so talk to one...