Apricus AP250GLE Скачать руководство пользователя страница 5

                          Issue Date: 01.06.16 

 

     

   Review Date: 01.06.16  

H0024 028626 A  

Installation Manual for EHW Tanks: MAN_INST_TANK_SRT(AA)|5

 

2.4.2 LEGIONELLA CONTROL 

Legionella  bacteria  can  be  found  naturally  in  the 
environment and thrives in warm water and damp places. 
It  can  weaken  the  body’s  immune  system,  which  can 
increase the chances of developing Legionnaires’ disease. 
To  ensure  legionella  growth  is  inhibited,  the  boosting 
regime must meet the guidelines as shown in Chapter 8: 
Auxiliary  Heating.  This  is  in  accordance  with 
‘AS3498.2009  Authorisation  requirements  for  plumbing 
products - water heater and hot-water storage tanks’ It is 
therefore,  very  important  that  the  auxiliary  boosting 
system remains on. It will only activate if the temperature 
falls below the temperatures outlined.  

2.5 EHW TANK 

2.5.1 HYDROGEN BUILD UP 

Glass  lined  (vitreous  enamel)  tanks  are  fitted  with  a 
Magnesium  anode  to  provide  corrosion  protection  for 
the  tank  from  the  storage  water.  Small  quantities  of 
hydrogen  gas  can  be  released  by  the  anode,  which 
generally  remains  dissolved  in  the  water  and  flushed 
away as hot water is used from the tank. Depending on 
the  water  quality  there  may  be  a  degree  of  hydrogen 
build-up in the tank if the water heater hasn't been used 
for two or more weeks. 

To  resolve  the  build-up  of  hydrogen  within  the  tank 
"purge" the tank for approximately 30 seconds from the 
lever on the PTRV.  

WARNING 

Ensure there are no open flames or ignition sources 
close to the tank 

 

 

Содержание AP250GLE

Страница 1: ...Issue Date 01 06 16 Review Date 01 06 16 H0024 028626 A Installation Manual for EHW Tanks MAN_INST_TANK_SRT AA 1 Apricus Solar Hot Water Installation Manual For Electric Hot Water Tanks Solar Ready...

Страница 2: ..._SRT AA 2 CONTENTS CHAPTER 1 INTRODUCTION 3 CHAPTER 2 WARNINGS AND PRECAUTIONS 4 CHAPTER 3 SITE INSPECTION 6 CHAPTER 4 COMPONENT INSPECTION 7 CHAPTER 5 SYSTEM PLUMBING 8 CHAPTER 6 COMMISSIONING 11 CHA...

Страница 3: ...d Tube functions to harness the solar energy by capturing and retaining the heat due to the presence of the vacuum Flow Line The plumbing line running from tank solar flow port to the inlet of the col...

Страница 4: ...ROL Where the mains supply pressure can exceed or fluctuate beyond the pressure of 500kPa a pressure limiting valve must be fitted to the cold mains line The device is installed after the duo valve is...

Страница 5: ...ery important that the auxiliary boosting system remains on It will only activate if the temperature falls below the temperatures outlined 2 5 EHW TANK 2 5 1 HYDROGEN BUILD UP Glass lined vitreous ena...

Страница 6: ...For glass lined tanks consider the positioning of the tank to allow room for anode removal and replacement maintenance The storage tank must be installed in a properly drained safe tray where leakage...

Страница 7: ...an electric element Ensure the tank has two brass plugs 4 2 NECESSARY COMPONENTS Ensure that the following components have been sourced for the installation These are not provided as a standard with t...

Страница 8: ...ATERIAL AND PIPE SIZE For domestic installations the recommended pipe is copper and the size is Two factors affect the choice of pipe sizing the flow rate and pressure drop These two factors are close...

Страница 9: ...ECV Pressure Reducing Valve Four Way Cross Figure 2 Mains Line Valves The set of mains line valves can be purchased as a kit from Apricus and provides the above components with insulating jackets to...

Страница 10: ...extracted to be supplied to the household 5 3 1 5 SENSOR PORTS When solar DHW system is set up the sensors must be coated with heat transfer paste and inserted through the cable gland into the approp...

Страница 11: ...er all the plumbing connections have been made EHW tank needs to be filled with water and purged of air To fill the system 1 Open the cold mains line and fill up the tank and open the hot water outlet...

Страница 12: ...he electrical element will be required to be directly connected to a 240V AC 50Hz mains power supply Flexible conduit is required to enclose any exposed electrical cables to the storage unit 7 2 2 THE...

Страница 13: ...us EHW tank ensure that each of the following processes is carried out prior to leaving the site 8 1 CHECKLIST PRIOR TO LEAVING INSTALLATION SITE EHW tank check Check all connections for leaks and tha...

Страница 14: ...sue Date 01 06 16 Review Date 01 06 16 H0024 028626 A Installation Manual for EHW Tanks MAN_INST_TANK_SRT AA 14 CHAPTER 9 APPENDIX 7 1 3 6 5 4 2 Figure 4 Typical Electric boosted solar hot water syste...

Страница 15: ...or adverse water conditions including excessive water pressure or temperature neglect of any kind or otherwise as a result of any use of the Unit contrary to the product manual or other instructions p...

Страница 16: ...annot be excluded under the Australian Consumer Law You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage You are als...

Отзывы: