Apricus AP250GLE Скачать руководство пользователя страница 16

                          Issue Date: 01.06.16 

 

     

   Review Date: 01.06.16  

H0024 028626 A  

Installation Manual for EHW Tanks: MAN_INST_TANK_SRT(AA)|16

 

 

Replacement of the Unit; 

 

Repair of the Unit; 

 

Refunding the cost of the Unit; 

 

Payment of reasonable costs of having the Unit 
repaired; 

 

Payment in respect of the reduced value of the 
Unit. 

Warranty  claims  can  be  placed  by  completing  the 
following steps:  

Contact Apricus Australia on 1300 277 428 and speak to 
our Warranty and Aftersales Department. 

 

Provide the serial number and model number of 
the  HWS  located  on  the  white  compliance 
sticker. 

 

Provide full name, address and contact number. 

 

Provide  proof  of  installation  of  the  unit,  for 
warranty  to  commence  from  the  Date  of 
Installation of the unit. If proof of installation or 
purchase  cannot  be  provided,  then  Date  of 
Manufacture  of  the  unit  will  be  used  to 
determine warranty commencement date. 

Our  goods  come  with  guarantees  that  cannot  be 
excluded  under  the  Australian  Consumer  Law.  You  are 
entitled  to  a  replacement  or  refund  for  a  major  failure 
and  for  compensation  for  any  other  reasonably 
foreseeable loss or damage. You are also entitled to have 
the goods repaired or replaced if the goods fail to be of 
acceptable quality and the failure does not amount to a 
major failure. 

For warranty policy for other parts provided by Apricus, 
please  see  the  Apricus  DHW  Warranty  Policy,  available 
from the Apricus website.  

Registering your Apricus solar ready tank will ensure 
that your details are placed on our computer system 
streamlining any future after-sales/service 
requirements. You can register your Apricus Australia 
product online at: www.apricus.com.au. 
 
Customers are encouraged to take photos of all system 
components for warranty purposes. This should include 
photos of the plumbing lines to and from the tank. Take 
note of your tank serial number. 

Contact Details: 

Apricus Australia Pty. Ltd. 
PO Box 6109 
Silverwater NSW 1811 
Australia 
 
Phone:   

1300 277 428 (Australia) 

Email:    

[email protected] 

Website:  

www.apricus.com.au 

 

 
 

Содержание AP250GLE

Страница 1: ...Issue Date 01 06 16 Review Date 01 06 16 H0024 028626 A Installation Manual for EHW Tanks MAN_INST_TANK_SRT AA 1 Apricus Solar Hot Water Installation Manual For Electric Hot Water Tanks Solar Ready...

Страница 2: ..._SRT AA 2 CONTENTS CHAPTER 1 INTRODUCTION 3 CHAPTER 2 WARNINGS AND PRECAUTIONS 4 CHAPTER 3 SITE INSPECTION 6 CHAPTER 4 COMPONENT INSPECTION 7 CHAPTER 5 SYSTEM PLUMBING 8 CHAPTER 6 COMMISSIONING 11 CHA...

Страница 3: ...d Tube functions to harness the solar energy by capturing and retaining the heat due to the presence of the vacuum Flow Line The plumbing line running from tank solar flow port to the inlet of the col...

Страница 4: ...ROL Where the mains supply pressure can exceed or fluctuate beyond the pressure of 500kPa a pressure limiting valve must be fitted to the cold mains line The device is installed after the duo valve is...

Страница 5: ...ery important that the auxiliary boosting system remains on It will only activate if the temperature falls below the temperatures outlined 2 5 EHW TANK 2 5 1 HYDROGEN BUILD UP Glass lined vitreous ena...

Страница 6: ...For glass lined tanks consider the positioning of the tank to allow room for anode removal and replacement maintenance The storage tank must be installed in a properly drained safe tray where leakage...

Страница 7: ...an electric element Ensure the tank has two brass plugs 4 2 NECESSARY COMPONENTS Ensure that the following components have been sourced for the installation These are not provided as a standard with t...

Страница 8: ...ATERIAL AND PIPE SIZE For domestic installations the recommended pipe is copper and the size is Two factors affect the choice of pipe sizing the flow rate and pressure drop These two factors are close...

Страница 9: ...ECV Pressure Reducing Valve Four Way Cross Figure 2 Mains Line Valves The set of mains line valves can be purchased as a kit from Apricus and provides the above components with insulating jackets to...

Страница 10: ...extracted to be supplied to the household 5 3 1 5 SENSOR PORTS When solar DHW system is set up the sensors must be coated with heat transfer paste and inserted through the cable gland into the approp...

Страница 11: ...er all the plumbing connections have been made EHW tank needs to be filled with water and purged of air To fill the system 1 Open the cold mains line and fill up the tank and open the hot water outlet...

Страница 12: ...he electrical element will be required to be directly connected to a 240V AC 50Hz mains power supply Flexible conduit is required to enclose any exposed electrical cables to the storage unit 7 2 2 THE...

Страница 13: ...us EHW tank ensure that each of the following processes is carried out prior to leaving the site 8 1 CHECKLIST PRIOR TO LEAVING INSTALLATION SITE EHW tank check Check all connections for leaks and tha...

Страница 14: ...sue Date 01 06 16 Review Date 01 06 16 H0024 028626 A Installation Manual for EHW Tanks MAN_INST_TANK_SRT AA 14 CHAPTER 9 APPENDIX 7 1 3 6 5 4 2 Figure 4 Typical Electric boosted solar hot water syste...

Страница 15: ...or adverse water conditions including excessive water pressure or temperature neglect of any kind or otherwise as a result of any use of the Unit contrary to the product manual or other instructions p...

Страница 16: ...annot be excluded under the Australian Consumer Law You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage You are als...

Отзывы: