Applied Digital, Inc. 19315 North State hwy 413 Branson West, MO 65737
417-297-0361 Fax 816-337-3398 E-Mail:
web:www.appdig.com
The T-Max® G2 Wireless Installation Guide
The T-Max® G2 wireless adapters allow you to connect an entire salon without running cables through the walls of your salon. The T-
Max® G2 also allows you to expand a current T-Max® Series without running additional cables throughout your salon.
The T-Max® G2 Series works by transmitting the T-Max® communications via a 900Mhz RF (radio frequency) signal. This allows
each timer in your salon to communicate with the T-Max® Manager or T-Max® Manager/Pro without the need of running cables
throughout your salon. The T-Max® G2 Wireless Series works with all Applied Digital, Inc. T-Max® products.
Important Installations Notes:
1) Make sure each G2 Access Point is installed upright with the antenna facing up.
2) All G2 Access Points units must be at least 2 feet apart even if separated by a wall. Make sure they are not right across from each
other on different sides on the same wall in adjacent rooms.
3) If connecting G2 Access Points on multiple floors, do not place an G2 Access Point directly above the G2 Access point connected
to the T-Max® Manager. Make sure they are offset by at least 2 feet.
4) Make sure the G2 Access Point is mounted above the highest point on the tanning bed (when the canopy is raised).
5) Make sure the G2 Access Point is not mounted next to metal such as metal studs in walls, vending machines, etc.
Connecting Two T-Max® 3As in Master/Slave
Set the address on the T-Max® 3As at the front desk to address 0 and the T-Max® 3As in the tanning rooms to address 1 as described
in the T-Max® 3A Users Guide. Connect the T-Max® 3A to the tanning bed as described in the T-Max® 3A and tanning bed user’s
guides. DO NOT run the provided modular cable from the front desk T-Max® 3A’s to the tanning room as described in the manuals.
Connect a T-Max® G2 System to each T-Max® 3As as shown here.
Connect the power supply to the power screw terminals on the back of the T-Max® 3A
(or connect the provided power supply with the Power Injector to the power input).
Connect the RJ22 cable between the T-Max 3A and the G2 Power injector. Then
Connect the RJ11 cable between the G2 Power Injector and the G2 Access Point.
Note: You do not have to connect the Power injector and T-Max® 3A to a common
power supply. You can provide power with separate power supplies if desired.
ADI PN:60000000053 (Optional)
T-Max® 3A at the front desk
T-Max® 3A in tanning room
Note:
If the tanning bed has an in bed T-Max® timer,
simply connect the T-Max® G2 Access Point directly
to the RJ-22 port on the tanning bed. You don’t need
to add anything if there is an in bed T-Max® Timer
and G2 Access Point already in your tanning bed.
T-Max® 3A (rear view)
Pwr in 9-12V
G2
Acce ss
Point
G2 Powe r Injector