![Applent Instruments AT851 Скачать руководство пользователя страница 27](http://html.mh-extra.com/html/applent-instruments/at851/at851_user-manual_2954894027.webp)
27
Advanced Testing Function
Figure 5-2
Set up Discharge
Current
Step 3:
Press
Numeric keys
or rotary
Knob
to input discharge current (such as
0.508
Enter
).
Step 4:
Press
Enter
key, battery cut-off voltage setup page appears:
Figure 5-3
Set up cut-off voltage
Step 5: Press
Numeric keys
or rotary
Knob
to input voltage (such as 1.5
Enter
)
Step 6:
Press
Enter
key to enter battery Testing Function Page (BAT) and battery testing
starts. (The load input will be turned on automatically)
Figure 5-4
Battery Testing
Function Page
During the testing, press
<
>
to watch current (I), power (P), battery capacity (B) or
discharge time (T). The discharge time format is HHH-MM (hour-minute)
When the battery voltage drops below the setting value, load input turns off.
Step 7: Press
shift
+
Battery
to return normal operation mode.
5.3
Battery Aging Testing Function
5.3.1
Set up the parameters
Step.1 Turn on
Step.2 Press Shift +6
(
Aging Set
)
to enter Battery Life Testing page
【
Battery Life Testing
】
Page [Press
Shift
+ 6]
DICH-I
Discharge Current 0~30A
CUT-V
Cut-off Voltage 0~120V
REST
Rest Time(in minutes) 0~999 minutes
CHAR
Charging Time(in minutes) 0~9999 minutes
LOOP
Number of Loops 0~999
RESET
Reset test data, test from a new beginning, the previously saved