1. Introduction

This four-component net radiometer, manufactured by Apogee Instruments, provides individual
measurement of net radiation components. This sensor features an SDI-12 output, eliminating
the need for multiple analog terminals to measure the individual components of net radiation.
The SN500SS offers a complete package that includes a net radiometer, mounting rod, pigtail
lead cable for data logger interface, and a carrying case.

NOTE:
This manual provides information only for CRBasic data loggers. For retired Edlog data logger
support, contact Campbell Scientific.

2. Precautions

l

READ AND UNDERSTAND the

Safety

section at the back of this manual.

l

Care should be taken when opening the shipping package to not damage or cut the cable
jacket. If damage to the cable is suspected, consult with Campbell Scientific.

l

The SN500SS is a precision instrument. Please handle it with care.

l

When cleaning the sensor, never use an abrasive material or cleaner on the diffuser.

3. Initial inspection

Upon receipt of the SN500SS, inspect the packaging and contents for damage. File damage
claims with the shipping company.

4. QuickStart

A video that describes data logger programming using

Short Cut

is available at:

www.campbellsci.com/videos/cr1000x-data logger-getting-started-program-part-3

.

Short

Cut

is an easy way to program your data logger to measure the sensor and assign data logger

SN500SS Net Radiometer

1

Содержание SN-500-SS

Страница 1: ...Revision 08 2021 Copyright 2018 2021 Campbell Scientific Inc...

Страница 2: ...ong cables 12 9 Maintenance calibration and troubleshooting 13 9 1 Maintenance 13 9 2 Calibration 13 9 3 Troubleshooting 14 Appendix A Importing Short Cut code into CRBasic Editor 15 Appendix B SDI 12...

Страница 3: ...c redundancy check aMC and aCC 21 B 1 9 Stopping a measurement command 21 B 1 10 Send data command aD0 aD9 21 B 1 11 Continuous measurement command aR0 aR9 22 B 1 12 Extended commands 22 B 2 SDI 12 tr...

Страница 4: ...TAND the Safety section at the back of this manual l Care should be taken when opening the shipping package to not damage or cut the cable jacket If damage to the cable is suspected consult with Campb...

Страница 5: ...procedure also shows using Short Cut to program the SN500SS 1 Open Short Cut and click Create New Program 2 Double click the data logger model 3 In the Available Sensors and Devices box type SN500SS...

Страница 6: ...wiring the sensor 5 Repeat steps three and four for other sensors 6 In Output Setup type the scan rate meaningful table names and Data Output Storage Interval NOTE Because of the delays using SDI 12 C...

Страница 7: ...he sensor is connected to the data logger check the output of the sensor in the data display in LoggerNet RTDAQ or PC400 to make sure it is making reasonable measurements 5 Overview The SN500SS is a f...

Страница 8: ...on accounts for a larger proportion of net radiation during the day when the sun is shining Longwave radiation contributes to net radiation during the day and at night Net shortwave radiation is the d...

Страница 9: ...1 s SDI 12 data transfer rate detector response times are 0 5 s Heater current drain at 12 VDC 63 mA heaters on communication enabled 1 5 mA heaters off communication enabled 0 6 mA heaters off commun...

Страница 10: ...complex the files that Short Cut creates are a great source for programming code to start a new program or add to an existing custom program NOTE Short Cut cannot edit programs after they are importe...

Страница 11: ...ample if the instrument is mounted 6 m above the surface 99 of the input of the lower sensors comes from a circular area with a 60 m radius To avoid shading or reflection effects and to promote spatia...

Страница 12: ...nd cable connected 2 Attach the mounting bracket to the vertical mounting pipe or CM200 series crossarm using the provided U bolt FIGURE 7 3 p 10 If mounted to a vertical pipe ensure that the pipe doe...

Страница 13: ...veling of the sensor using the sensor bubble level 5 Tighten the four screws on top of the mounting bracket to properly secure the support arm so that it does not rotate FIGURE 7 3 p 10 CAUTION The fo...

Страница 14: ...the values are ready Rather the data logger picks up the data with the D command on the next pass through the program Another measurement request is then sent so that data is ready on the next scan N...

Страница 15: ...or incoming LW 3 Voltage signal for outgoing LW 4 Sensor body temperature for outgoing LW mV C mV C aM4 aC4 aMC4 or aCC4 Albedo W m 2 aXHON Turn heater on aXHOFF Turn heater off Returns the SDI 12 Add...

Страница 16: ...time of day at any location in the world It is most accurate when used near solar noon in spring and summer months where accuracy over multiple clear and unpolluted days is estimated to be 4 in all c...

Страница 17: ...fied by the SDI12Recorder instruction 2 Check the voltage to the sensor with a digital voltage meter If a switched 12V terminal is used temporarily connect the red wire to a 12V terminal non switched...

Страница 18: ...ted for additional refinement NOTE Once the file is edited with CRBasic Editor Short Cut can no longer be used to edit the program it created 2 To add the Short Cut wiring information into the new CRB...

Страница 19: ...Sniffer Mode videos B 1 SDI 12 command basics SDI 12 commands have three components l Sensor address a a single character and the first character of the command Use the default address of zero 0 unles...

Страница 20: ...RC CR LF Extended Commands aXNNN a values CR LF 1 Information on each of these commands is given in the following sections B 1 1 Acknowledge active command a The Acknowledge Active command a is used t...

Страница 21: ...until verification information is available n the number of values to be returned when one or more subsequent D commands are issued B 1 4 Address query command Command requests the address of the con...

Страница 22: ...0 immediately indicates that it will return two values within the next 35 seconds 0 CR LF Within 35 seconds sensor 0 indicates that it has completed the measurement by sending a service request to th...

Страница 23: ...sor Y immediately indicates that it will have 6 06 values ready for collection within the next 40 040 seconds ZC The data logger makes a request to sensor Z to start a concurrent measurement Z02010 CR...

Страница 24: ...t www sdi 12 org to learn more about how the CRC code is developed B 1 9 Stopping a measurement command A measurement command M is stopped if it detects a break signal before the measurement is comple...

Страница 25: ...in the values part of the response to the R command B 1 12 Extended commands Many sensors support extended SDI 12 commands An extended command is specific to a make of sensor and tells the sensor to...

Страница 26: ...use their transparent mode The following examples show how to enter transparent mode and change the SDI 12 address of an SDI 12 sensor The steps shown in Changing an SDI 12 address p 23 are used with...

Страница 27: ...sponds with its SDI 12 address If no characters are typed within 60 seconds the mode is exited In that case simply type SDI12 again press Enter and type the correct control port number when prompted 1...

Страница 28: ...lar to that shown for the CR1000X B 3 References SDI 12 Support Group SDI 12 A Serial Digital Interface Standard for Microprocessor Based Sensors Version 1 4 River Heights UT SDI 12 Support Group 2017...

Страница 29: ...ther manufacturer s products that are resold by Campbell Scientific are warranted only to the limits extended by the original manufacturer Refer to www campbellsci com terms warranty for more informat...

Страница 30: ...ion or Repair Reference number contact your CAMPBELL SCIENTIFIC regional office Please write the issued number clearly on the outside of the shipping container and ship as directed For all returns the...

Страница 31: ...rohibit climbing by other persons Take reasonable precautions to secure tripod and tower sites from trespassers l Use only manufacturer recommended parts materials and tools Utility and Electrical l Y...

Страница 32: ...nfo campbellsci fr www campbellsci fr Germany Location Phone Email Website Bremen Germany 49 0 421 460974 0 info campbellsci de www campbellsci de India Location Phone Email Website New Delhi DL India...

Отзывы: