Aplisens CS-27/BAK Скачать руководство пользователя страница 1

 

 

 
 
 

 

 

 

INSTRUCTION MANUAL

 

 

 

CS-27/W; CS-27/BAK

 

HYDROSTATIC FUEL LEVEL PROBE

 

 FOR INSTALLATION ON THE FUEL FILLER

 

 

 

 

Содержание CS-27/BAK

Страница 1: ...INSTRUCTION MANUAL CS 27 W CS 27 BAK HYDROSTATIC FUEL LEVEL PROBE FOR INSTALLATION ON THE FUEL FILLER ...

Страница 2: ...y and electromagnetic compatibility applicable for this kind of installation In any installation equipped with measuring devices there is an injury hazard from compressed agent in case of a leak Follow all safety requirements during the installation use and inspection of the device In case of malfunction disconnect the device and return it to the producer or an authorized service unit for repair I...

Страница 3: ...protection class 10 9 6 Housing 10 9 7 Marking10 10 INSPECTION 11 10 1 Periodical inspection 11 10 2 Non periodical inspection 11 11 SCRAPPING DISPOSAL 11 12 ADDITIONAL INFORMATION 11 1 INTRODUCTION The subject of this instruction manual is the CS 27 W and CS 27 BAK hydrostatic fuel level probe for installation on the fuel filler The manual includes data hints and recommended action for installati...

Страница 4: ...ectronic circuit of the device Damage assessment and possible repair can only be made by the producer or an authorized unit Do not use the device when it is damaged If malfunction occurs disconnect the device 1 SET LIST Along with the device the user receives the following a Product certificate functioning as a warranty card b Declaration of conformity on customer s request c Instruction Manual de...

Страница 5: ...and locomotives The CS 27 BAK is a combination of the CS 27 W probe with a BAK filler security for monitoring access to the fuel filler on trucks machinery construction vehicles and others optionally with additional event signaling system for the driver 3 2 Structure and operation The CS 27 W fuel level probe measures the hydrostatic pressure of liquid whose values is proportional to the height of...

Страница 6: ...cted to a monitoring system that records the ongoing events The CABIN SIGNALLING MODULE is equipped with a SILENT OPEN feature removing the cap without the sound alarm in the cabin and ALARM MEMORY information on tampering with fuel cap when the driver is not present in the cabin The CABIN SIGNALLING MODULE generates two signals for removing the cap normal open NO and normal connected NC All signa...

Страница 7: ...IO CS 27 W CS 27 BAK 5 02 B 003 Pic 2 CS 27 BAK 60 CS 27 W 60 hydrostatic fuel level probe overall dimensions 4 INSTALLATION 7 1 CS 27 BAK 80 CS 27 W 80 mechanical installation ...

Страница 8: ...o minimize possible thermal and mechanical damage resulting from regular usage of vehicle Thread the sealing cord with bead through sealing openings so that it does not screen the rivet head wrap the cord around the protective pipe and seal it Insert silicone into mounting openings and push in rubber plugs Cut off the protruding part of plug Screw the cap on Unscrew and screw the cap back on sever...

Страница 9: ... cabin in such a way as to minimize possible thermal and mechanical damage resulting from regular usage of vehicle Thread the sealing cord through the opening in screw head locking screw wrap it around the protective pipe and seal it Screw the cap on Unscrew and screw the cap back on several times to verify the stability of mounting on the tank filler 1 CONNECTION All connection and installation s...

Страница 10: ...IO CS 27 W CS 27 BAK 8 02 B 003 ...

Страница 11: ...m ambient and working parameters Working temperature range 25 80 ºC custom made 40 ºC 80 ºC Compensation temperature range 25 ºC 50 ºC Relative humidity 30 90 Atmospheric pressure 80 120kPa Acceptable levels of vibration up to 2 5m s2 Dusting Any Working position Vertical Concentration of active components in atmosphere No corrosive components 9 3 Measurement range data Measurement range up to 200...

Страница 12: ...iller diameter ø60 1 body with gland 2 body with coupling RS1 Digital output signal U2 Voltage output signal R Sensor mounted on adjustable arm P Sensor mounted on bendable rod 1 With digital output signal RS state interface type 232 or 485 2 With voltage output signal U state voltage value 0 10V or other Example marking CS 27 BAK 80 1 RS 485 R Fuel level probe with filler security filler diameter...

Страница 13: ...on as necessary If there is no signal on the transmission line or signal value is incorrect check the condition of the cable the condition of connections on clamps etc Check if the power voltage value and load resistance is correct If the line is functional check the operation of the device 11 SCRAPPING DISPOSAL Used or damaged devices must be scrapped according to EU Directive 2002 96 EU on used ...