Instructions for Installing an AQUAstay Tank
for rainwater
for drinking water
(W 270 certifi cate)
for waste water
EN
Страница 1: ...Instructions for Installing an AQUAstay Tank for rainwater for drinking water W 270 certificate for waste water EN ...
Страница 2: ... be carried out by a professional company with qualified experts who are familiar with the installation instructions Follow the instructions for safe work when executing the works another person must be present to protect you especially when manipulating and installing the tank The lid of the tank must be kept closed at all times to prevent the possibility of an accident The tank shall be installe...
Страница 3: ... and 200mm in diameter A steadying inlet an overflow siphon and filter Lids such as lid with seal and additional protection TELESCOPE or RING for raising the entrance to the tank Volumen Height H Diameter D Length L Weight 2 0 m 1 6 m ø 2 3 m ø 1 7 m ø 1 4 m 2 000 l L 2 500 l L 3 500 l XL 5 000 l XL 6 000 l XL 7 000 l XL 10 000 l XL 8 000 l XXL 10 000 l XXL 12 000 l XXL 16 000 l XXL 18 000 l XXL 2...
Страница 4: ...side 3 1 1 Assembly of Fittings The tank s entry fittings differ and are adapted to your requirements You must choose a suitable pipe and the appropriate entry seal The installation of the seal and the execution of a suitable opening must be carried out by a qualified individual with the tools suitable for such a task a hole saw a scraper a food grade lubricant etc 3 2 EXCAVATION OF A CONSTRUCTION...
Страница 5: ...st be used When using granular material the permissible grain size is from 0 to 32mm or from 0 to 16mm when using crushed material Do not use frozen material Suitable bedding thickness is from 20 to 30cm and must be compressed to 97 Proctor compaction When groundwater is present the bedding must be made out of MB15 lean concrete Sand bedding min 20cm ...
Страница 6: ...Simultaneously with backfilling the body of the tank water must be poured into the tank itself so that the level of the backfill material equals the water level in the container When backfilling pay special attention to the space on the bottom Using manual aids fill in and consolidate the entire empty space thus preventing potential subsequent deformation of the bottom When backfilling the PE cont...
Страница 7: ...y to the height of 70cm Wire mesh and an additional wire rod are inserted into the foundation slab in order to attach a galvanised fastening steel tape The fastening tape is fixed in place with three M8x40 stainless screws The fastening tape may enclose the body of the tank and must not be subjected to a tensile force that would deform the shape of the body of the tank VIEW A Wire mesh M8 screw Ro...
Страница 8: ...hoosing a lid with a safeguard is made by the buyer hence in the event of an accident the seller and manufacturer shall not be held liable for potential consequences if a lid without a safeguard has been chosen 4 ASSEMBLY OF THE LID AND FINISHING WORKS After the backfilling of the tank is finished the height of the manhole has to be adjusted to the surrounding terrain by cutting the ring of the ta...