background image

22

DISK DISPOSAL

The disks cannot be reused. Over time, the water in reacted disks will evaporate. 

Disks can be recycled. Warning: Recyclers should check with the local authorities. 

Some states may require that no chemical residue remains on the plastic or may 

not be able to accept plastic waste with stainless steel mixing beads. 

GENERAL INFORMATION

PACKAGING AND RETURNS 

Experienced packaging personnel at LaMotte Company assure adequate 

protection against normal hazards encountered in transportation of shipments. 

After the product leaves the manufacturer, all responsibility for its safe delivery 

is assured by the transportation company. Damage claims must be 

fi

 led 

immediately with the transportation company to receive compensation for 

damaged goods. Should it be necessary to return the instrument for repair or 

servicing, pack the instrument carefully in a suitable container with adequate 

packing material. A return authorization number must be obtained from LaMotte 

Company by calling 1-800-344-3100 or 1-410-778-3100, ext. 3 or emailing tech@

lamotte. com. Attach a letter with the authorization number to the shipping carton 

which describes the kind of trouble experienced. This valuable information will 

enable the service department to make the required repairs more ef

fi

 ciently.

GENERAL PRECAUTIONS 

Read the instruction manual before attempting to set up or use the instrument. 

Failure to do so could result in personal injury or damage to the meter. The API 

AQUASPIN should not be stored or used in a damp or excessively corrosive 

environment. Care should be taken to prevent water or reagents from entering 

the photometer chamber. Wet disks should never be put into the photometer 

chamber.

SAFETY PRECAUTIONS

Read the safety precautions on the labels of all reagent containers and 

packaging prior to use. Ensure that the protection provided by this equipment is 

not impaired. Do not install or use this equipment in a manner that is not indicated 

in this manual.

LIMITS OF LIABILITY 

Under no circumstances shall LaMotte Company be liable for loss of life, property, 

pro

fi

 ts, or other damages incurred through the use or misuse of its products.

CE MARK

The API AQUASPIN meter has been independently tested and has earned the 

European CE Mark of compliance for electromagnetic compatibility and safety. 
This meter complies with Part 15 of the FCC rules. Operation is subject to the 

following two conditions: (1) This meter may not cause harmful interference, and 

(2) this meter must accept any interference received, including interference that 

may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for 

a Class B digital meter, pursuant to Part 15 of the FCC Rules. These limits are 

designed to provide reasonable protection against harmful interference when the 

equipment is operated in a residential environment. This equipment generates, 

uses, and can radiate radio frequency energy and, if not installed and used in 

Содержание AP-3580

Страница 1: ...Simple Precise Digital Water Testing...

Страница 2: ...2...

Страница 3: ...k Cover 12 Meter Check Disk 12 Usb Cable 12 Battery 12 Settings 13 TROUBLESHOOTING Meter Troubleshooting Guide 14 Meter Check Disk Troubleshooting Guide 15 AQUASPIN Web Application Troubleshooting Gui...

Страница 4: ...re register and clicking Create account 1 You will need to enter the serial number of your meter to create your account The serial number can be found on the bottom of your AQUASPIN meter or on your w...

Страница 5: ...t time to doing the update and nothing else on your computer to allow the update to not be disrupted PC CONNECTION When the API AQUASPIN meter is connected to a PC via USB cable the onboard touchscree...

Страница 6: ...O NOT overfill the disk If the disk is overfilled sample water will flow out of the overflow hole in the center of the disk If this happens be sure to dry the disk completely before running the test O...

Страница 7: ...e air more than necessary Do not transport the meter with a disk in the chamber Store disks at 70 80 F 21 27 C METER When a filled disk is placed in the chamber with universal disk cover and the lid i...

Страница 8: ...election tap the icon or word on the screen with a fingertip fingernail pencil eraser or stylus Gently wipe smudges from the screen with the Cloth Wipe Do not touch the screen with a sharp object Do n...

Страница 9: ...ount enter their email address and tank type under the REGISTER NEW CONSUMER ACCOUNT section 6 Next select the disk type the disk type can be found on the foil packet Then hit RUN TEST button on the c...

Страница 10: ...s to turn the meter off NOTE Remove salt residue daily Salt will damage the meter and cause inaccurate results See the CLEANING section in the manual NOTE For water samples over 100 F 38 C subtract 0...

Страница 11: ...esh Q104 21 43 23 May Fresh Q104 20 41 22 May Fresh Q104 20 36 22 May Fresh Q104 Test History View Selected Results Delete Selected Results History Settings Select Auto Save Go to Top Go to Bottom Scr...

Страница 12: ...Check Disk is inserted in the meter and Rotary Calibration is chosen from the Settings Menu the alignment of the hub and disk is evaluated The results are analyzed and reported as Pass or Fail For us...

Страница 13: ...at any time Set Language There is one language option English Tap to exit to the Settings menu Calibration Tap to run an angle calibration to evaluate the alignment of the hub and disk Tap to exit to...

Страница 14: ...filled disk or air bubble Solution Fill disk correctly see FILLING Range Error Raw data out of range Contact Support Output Error Decreased light intensity Possibly dirty lens Clean lens see CLEANING...

Страница 15: ...heck Disk with water Water is not used during the meter check procedure Range Check Procedure The Meter Check Disk is used to verify the performance of a meter It is not used to recalibrate the meter...

Страница 16: ...ion the LED Calibration should be performed before the Angle Calibration Follow the Cleaning procedure on page 21 to clean the light chamber and optic lenses 1 Tap to go to settings 2 Tab Calibration...

Страница 17: ...Universal Disk Cover Code 1719 can be used with the API AQUASPIN Keep the chamber clean and dry Gently swab LED and photodiode lenses located around the hub with a cotton swab dampened with streak fr...

Страница 18: ...able 3 To express the test result as ppm Ionized Ammonia NH4 subtract the Unionized Ammonia determined in step 2 from the Total Ammonia 10 C 15 C 20 C 25 C pH Fresh water1 Salt water2 Fresh water Salt...

Страница 19: ...nm 635 nm Display Color Capacitive Touchscreen 3 5 in 320 x 240 pixel resolution Wavelength Accuracy 2 nm Wavelength Bandwidth 10 typical Photometric Range 2 to 2 AU Photometric Precision 0 01 AU at...

Страница 20: ...anada IC Certification FCC ID WAP2001 License IC 7922A 2001 CE Europe Complies with Directive 1999 5 EC MIC Japan 005 101007 KC Korea MSIP CRM Cyp 2001 EMC EU ETSI EN 301489 1 US FCC PART 15 B CAN ICE...

Страница 21: ...horough cleaning when necessary Do not use streak free window cleaner or similar cleaners on the touchscreen REPAIRS Should it be necessary to return the meter for repair or servicing pack the meter c...

Страница 22: ...ument Failure to do so could result in personal injury or damage to the meter The API AQUASPIN should not be stored or used in a damp or excessively corrosive environment Care should be taken to preve...

Страница 23: ...ance LaMotte Company warrants this instrument to be free of defects in parts and workmanship for 2 years from the date of shipment If it should become necessary to return the instrument for service du...

Страница 24: ...pifishcare com Mars Fishcare North America Inc 50 E Hamilton St Chalfont PA 18914 Disk US Patent No 8 734 734 AP 3580 MN 07 22 20 Manufactured by LaMotte Company PO Box 329 Chestertown MD 21620 800 34...

Отзывы: