9    Complete Kit 

 

      9.1 What’s in the box 
 

 

Content

 

Quantity

 

1.

 

  DO850 Portable Optical Dissolved Oxygen Meter 

 

1

 

2

 

  DO803 Optical Dissolved Oxygen Probe

 

1

 

3

 

  Probe Calibration Sleeve

 

1

 

4

 

  Small Screwdriver

 

1

 

5

 

  Carrying Case

 

1

 

6

 

  Sponge for Water Storage (spare)

 

4

 

7

 

  Instruction Manual

 

1

 

 

9.2 Accessories for separate purchase 

 

 

10    Warranty 

 

 
10.1 The warranty period of the DO850 instrument (only the instrument) is 3 years from the 

date of purchase. That of DO803 optical DO probe (excluding sensor cap) is 2 years from 
the date of purchase. That of DO8032 sensor cap is 1 year from the date of purchase. If the 
above  products  or  parts  within  the  warranty  period  is  not  functional  due  to  raw  material 
defects or poor manufacturing, they are free for repair or replace. 

 
10.2  Damage  and  malfunction  of  the  product  caused  by  the  following  reasons  are  not 

covered by the warranty: 

 

(A) 

Fails to install, operate, or use the product in accordance with the instruction manual, or 
if the product is damaged by abuse or incorrect use; 

(B) 

The sensor cap is damaged by external force and can not work; or the electrode cable 
is damaged or twisted due to external force; 

Model 

Name 

DO803 

Optical DO probe (3m cable. with sensor cap and calibration sleeve) 

DO810 

Optical DO probe (10m cable, with sensor cap and calibration sleeve) 

DO8032  Sensor cap 

DO8031  Calibration sleeve 

Содержание DO850

Страница 1: ...1 DO850 Portable Optical Dissolved Oxygen Meter Instruction Manual APERA INSTRUMENTS LLC aperainst com v3 0...

Страница 2: ...ng 6 3 8 Automatic Power Off 6 4 Optical Dissolved Oxygen Probe 7 4 1 Probe Structure 7 4 2 Probe Maintenance 7 4 3 Sensor Cap 8 5 Preparation for Calibration 8 5 1 Dissolved Oxygen Units Selection 8...

Страница 3: ...n such as scratches to the light shielding layer the sensor cap has up to 8000 hours of service life Easy to calibrate and maintain Probe is equipped with a calibration storage sleeve which makes cali...

Страница 4: ...0 response Calibration Points Saturation Point Zero Oxygen Temperature Compensation Automatic 0 to 50 Pressure Compensation Automatic 60 to 120 kPa Salinity Compensation Manual 0 to 45 ppt Temperature...

Страница 5: ...surement mode press the key for 2 seconds to enter the calibration mode Short Press To cancel any operation press to return to measurement mode Short Press In the menu mode press the key to change the...

Страница 6: ...n Select On to turn on automatic locking When the reading is stable for more than 10 seconds the meter automatically locks the measured value and displays the HOLD icon as shown in Figure 8 When auto...

Страница 7: ...slow The electrode calibration sleeve is used to store the probe A Short term storage less than 30 days The probe head is kept in the calibration sleeve Always keep the sponge inside the calibration s...

Страница 8: ...xide for 15 to 30 minutes and then rinse off with clean water D The sensor cap has a service life of more than 8000 hours When the probe is not being used the service life will not be reduced so the a...

Страница 9: ...ity of freshwater is 0 to 0 5ppt salinity of seawater is 35ppt 6 Calibration 6 1 Saturated Oxygen Calibration A This procedure requires the use of a calibration sleeve to allow the probe to be calibra...

Страница 10: ...he sensor cap can adversely affect the stability of the measurement Please pay special attention to this situation See Section 4 2 Probe Maintenance for details C The instrument has factory default se...

Страница 11: ...ppm P3 2 Resolution Selection 0 01 0 1 mg L ppm P3 3 Salinity Compensation 0 to 45 ppt P3 4 Air Pressure Calibration 60 to 120 kPa P3 5 Back to Factory Default No Yes P4 0 Basic parameter P4 1 Temp Un...

Страница 12: ...press or to switch P4 1 temperature unit 1 In P4 0 mode Press to enter P4 1 mode 2 Press flashes Press to select Press to confirm 2 Press to enter P4 2 mode or to return to measurement mode P4 2 Auto...

Страница 13: ...the date of purchase If the above products or parts within the warranty period is not functional due to raw material defects or poor manufacturing they are free for repair or replace 10 2 Damage and...

Страница 14: ...e measured value is not stable prolong the stabilization time until is fully stabilized then press to finish 3 Check the sensor cap If it is contaminated it can be cleaned if dried out it can be hydra...

Страница 15: ...7 62 7 22 19 0 9 28 8 79 8 33 7 90 7 48 7 09 20 0 9 09 8 62 8 17 7 75 7 35 6 96 21 0 8 92 8 46 8 02 7 61 7 21 6 84 22 0 8 74 8 30 7 87 7 47 7 09 6 72 23 0 8 58 8 14 7 73 7 34 6 96 6 61 24 0 8 42 7 99...

Страница 16: ...82 07 820 73 95 28 43 722 0 96 26 962 59 80 23 94 608 0 81 06 810 60 94 28 13 714 4 95 25 952 46 79 23 64 600 4 80 05 800 47 93 27 83 706 8 94 23 942 32 78 23 34 592 8 79 03 790 34 92 27 53 699 2 93 2...

Отзывы: