GB

IE

GCHEP60/ 70/ 90/BKN-B

Curved Glass Hood

60901145_03 GCHEP60_70_90BKN-B

Содержание GCHEP60BKN-B

Страница 1: ...GB IE GCHEP60 70 90 BKN B Curved Glass Hood 60901145_03 GCHEP60_70_90BKN B...

Страница 2: ...01 x 1 04 x 1 05 x 1 02 x 1 03 x 1 06 x 1 07 07 x 4...

Страница 3: ...1 1 11 x 4 12 x 6 3 9 x 32mm 08 x 4 10 x 6 09 x 1 13 x 4 3 4 x 10mm...

Страница 4: ...GB IE Curved Glass Cooker Hood 05 Installation 23 GCHEP60 70 90 BKN B 4...

Страница 5: ...07 Safety 09 In more detail 13 Product functions Operation Care and maintenance Troubleshooting Recycling and disposal Technical and legal information CE Declaration of conformity 14 14 15 18 19 19 22...

Страница 6: ...6 Getting Started Getting started GB IE Before you start 07 Safety 09...

Страница 7: ...please check that it is not damaged If in doubt do not use the appliance but contact Customer Services on 0344 800 1128 UK 01 4475261 Ireland Check the package and make sure you have all of the parts...

Страница 8: ...ls required 6mm CARBFILT4 UK IE SELF ADHESIVE ALUMINIUM TAPE Accessories not supplied Recirculation Extraction CARBON FILTER ORDERING HOTLINE 0344 800 1128 UK 01 4475261 IE 125mm VENT PACK 2 UK IE 8 G...

Страница 9: ...hot during its operation Accessible parts may become hot during use Young children should be kept away Care should be taken to avoid touching the appliance The Manufacturer highly recommends that thi...

Страница 10: ...ed it must be replaced by the manufacturer its order to avoid a hazard Do not allow the electric cables to touch the hot parts of the appliance Make sure that the power cord is not caught under or in...

Страница 11: ...s outlets Do not connect the hood to that room ventilation is appropriate with the local authorities Make sure the maximum air room does not exceed 4 Pa 0 04 mbar The room must have adequate ventilati...

Страница 12: ...ns of damage or imperfection Contact customer services Flambe cooking must not be carried out underneath this appliance When installing the appliance make sure that the following distances between the...

Страница 13: ...n more detail In more detail GB IE Product functions 14 Operation 14 Care and maintenance 15 Troubleshooting 18 Recycling and disposal 19 Technical and legal information 19 CE Declaration of conformit...

Страница 14: ...pliance at the switched fused connection unit The appliance is ready for operation functions Five button panel Lighting on and off Extractor fan off Extractor fan speed button speed 1 Extractor fan sp...

Страница 15: ...g always switch off the electricity supply before carrying out maintenance work on the hood In the event of a fault contact customer services Bulb replacement The Bulb may be hot leave it 10 minutes b...

Страница 16: ...Care and maintenance 2 X ACTIVE CHARCOAL FILTER NOT SUPPLIED MODEL NUMBER CARBFILT4 UK IE CLICK 16 In more detail GB IE...

Страница 17: ...the cleaning process Important the hood is used for more than 2 hours a day Always use genuine Care and maintenance FUSE OFF Warning Always switch off the electricity supply before performing mainten...

Страница 18: ...bulb blown Replace with a bulb with correct rating Power connection loose Check power supply Suction performance reduced Speed may be too low Select a higher speed Distance between the cooker hood an...

Страница 19: ...s product is disposed of correctly you will help to avoid possible negative consequences for the environment and public health which could occur if this product is not handled correctly To receive mor...

Страница 20: ...A 3AMP FUSE FUSE ON EUR UK Direct Connection If the appliance is being connected directly to the mains an omnipolar circuit breaker must be installed with a minimum opening of 3mm between contacts If...

Страница 21: ...CE MUST NOT BE EARTHED The appliance is supplied with a 2 core mains cable and must be connected to the electricity supply via a double pole switch having a 3mm minimum contact gap on each connector F...

Страница 22: ...e hoods Standard EN 55014 Limits and methods of measurement of radio disturbance Standard EN 61000 3 2 Electromagnetic compatibility limits for harmonic Standard EN 61000 4 5 Electromagnetic compatibi...

Страница 23: ...23 Appendix Appendix FR Installation Information for EU66...

Страница 24: ...01 CARBFILT4 UK IE UK IE VENT PACK 2 24 Installation You can choose two type of installation Ducted option Recirculation option...

Страница 25: ...02 DIM B DIM B MIN 750mm MIN 650mm 170 122 34 170 90 Gas Electric MAX 785 25...

Страница 26: ...12 x 2 10 x 6 03 04 Maximum gap between top 2 holes and middle 2 holes can be no more than 735mm dependant on ceiling height 12 x 2 03 2mm 2mm 2mm 10 12 03 12 785 26...

Страница 27: ...6 27 09 Remove the aluminium Filter 07 x 4 08 x 4 11 x 4 Insert the the 4x bolts rubber washer and washer and tighten with the allen key ensuring not to over tighten as this may cause damage to the gl...

Страница 28: ...07 08 28 Replace the aluminium Filter 12 x 2...

Страница 29: ...09 10 06 13 06 13 x 2 29 Fix the Ducting Tube 125 or 150 using tape or clamp Vent Pack 2 UK IE x 1 Fix the Collar...

Страница 30: ...11 12 30 02 13 02 x 1 13 x 2...

Страница 31: ...13 31 Remove the Protector film For recirculating option refer to Care and maintenance section Note For electrical connection see Technical and legal information section...

Страница 32: ...e increase factor f 1 6 Fluid Dynamic Efficiency FDEhood 10 7 Energy Efficiency Index EEIhood 86 9 Measured air flow rate at best efficiency point QBEP 159 2 m 3 h Measured air pressure at best effici...

Страница 33: ......

Страница 34: ......

Страница 35: ......

Страница 36: ...Apelson Appliances UK Limited Unit 3 Normandy Landings Pope St Castleford WF6 2AG GB IE...