background image

E-ITN 30.51 / 30.6

Electronic double-sensored heating cost allocator with radio module

OPERATION MANUAL

1. Application

E-ITN 30.51 and E-ITN 30.6 cost allocators for heat 
meters is a device that registers the temperature dif-
ference between the radiator surface and the room.
On this basis the calculation system, strictly con-
nected with the structure of given allocator, allows 
to determine which part of the costs of heat con-
sumed during the heating period in the given build-
ing falls to the apartment in which given radiator is 
located.

2. Cost allocator structure

The allocator is equipped with mechanical and elec-
tronic seals that protect it against unauthorized ac-
cess. The electronic seal is activated already during 
the production process, whereas the mechanical 
seal (clamp seal) is activated during the installation 
of the device on a radiator. In case of unauthorized 
opening of the allocator, the device will save the date 
of electronic seal breakage in its memory and will 
stop showing the data on the display. The display 
will show the desription „Open”, which indicates un-
authorized opening of the device. The allocator will 
continue the measurement and data transmission! 
The information about broken electronic seal will be 
available among the data transmitted via the radio 
module as well as the IR infrared interface. The de-
vice is powered with lithium battery and equipped 
with 16 byte microcontroller with very low energy 
consumption, as well as with the radio module.

3. Cost allocator performance

The cost allocator operates based on double-sensor 
measurement method, where one sensor measures 
the temperature of radiator surface and the other 
sensor measures the air temperature in the room. 
The allocator starts to calculate the units when the 
temperature of radiator measurement sensor is 
higher or equal 23 °C and the difference between 
the temperature of radiator surface and room tem-
perature is higher or equal 5 °C. The units shown on 
LCD display are dimensionless units not connected 
with any physical quantities. The amount of calcu-
lated units allows to settle the costs incurred to the 

occupant for heating the flat.

Warning: 

The cost allocator is resistant against any 

manipulations. In the event of a manipulation, the 
allocator automatically switches to one-sensor op-
eration mode (less convenient for the users). The al-
locator will switch back to standard operation mode 
(double-sensor mode) after the manipulation has 
stopped.

4. Failure mode

The cost allocator switches automatically from op-
eration mode to failure mode when the microcon-

troller  identifies  a  serious  system  failure.  In  failure 

mode the allocator constantly shows „Error” mes-
sage on the display. Cost allocator does not meas-
ure the temperature and neither calculates nor 
transmitts the measured data, it only updates the 
date. In case of power failure, the data will not be 
completely lost because the allocator saves the data 
to its non-volatile memory every day. Saved data can 
be restored using special equippment. 

5. Battery life

Battery life is 10 years + 1 year. The information 
about battery life is stored in microcontroller’s 
memory. In case of the allocator’s operation in the 
last (tenth) year of battery life, the display will show 

a flashing symbol „BAT”. After the expiry of this pe

-

riod „BAT” symbol will be displayed permanently. 

5-digit LCD display
+ 2 special char-
acters

Read button 1x 

press and release

Readings will appe-

ar on the display as 

described in point 6

4-digit code with 

the indication of 

respectively the 

month and two last 

numbers of manu-

facturing year

Device type

IR port - manual 
infrared reading 

of indications

8-digit device 
number

Bar code  

of the device

Отзывы: