APAR AR601 Скачать руководство пользователя страница 1

 

 

 

 

User Manual 

 

Temperature Controller 

AR601 

 

 

 

 

 

 

 

 

 

 
Version 3.1 
2013.02.13 

 

 

Содержание AR601

Страница 1: ...User Manual Temperature Controller AR601 Version 3 1 2013 02 13...

Страница 2: ...STALLATION INSTRUCTIONS 3 3 AR601 CONTROLLER GENERAL CHARACTERISTICS 3 4 TECHNICAL SPECIFICATIONS 4 5 IMPORTANT USAGE INFORMATION 5 6 HOUSING AND INSTALLATION METHOD 5 7 TERMINAL STRIPS AND ELECTRICAL...

Страница 3: ...ld be single point and connected as close to the device as possible Avoid placing test signal leads directly next to and parallel to power lines and supply cables It is recommended to twist signal wir...

Страница 4: ...nt range 1 digit Thermocouple inputs additional 2 C cold ends temperature Response time 0 5 2s programmed by parameter 2 Relay outputs P1 For resistance loads 8A 250Vac For inductive loads 2A 250Vac F...

Страница 5: ...achieve it is to connect suitable suppression module directly to inductive load contacts In general to each type of inductive load suitable suppression module should be selected Modern contactors are...

Страница 6: ...display and change mode enter see section 9 Displayed errors deleting or Move to next previous parameter marked as UP or DOWN in manual Displayed errors deleting Available keys combinations SET DOWN...

Страница 7: ...digits is possible using SET button Parameter 18 password can be changed After entering password correctly each press of SET button will display message and enter configuration parameters setup menu w...

Страница 8: ...N 20 Display brightness step 10 Cautions 1 for response time is 0 5 second for response time is about 2 seconds Higher filtration level means more smooth measured value and longer response time 2 ON O...

Страница 9: ...1 second The principle of operation for P type regulation proportional control for output P1 or SSR1 is shown in the illustration c d To select PID parameters suitable for certain regulation object i...

Страница 10: ...m below actions Press SET button shortly then using UP button go to parameter After pressing SET button display will show selected parameter value OFF ON Pressing SET button simultaneously with UP or...

Страница 11: ...between second and third oscillation 3 Set configuration parameters proportionality range P integration time T s differentiation time T 4 s pulsation period T 8 s 16 PID PARAMETERS CORRECTION Autotuni...

Отзывы: