is a trademark of Apache Pipeline Products and protected by U.S. Patent 5263220
INSTALLATION - REASSEMBLY
TECHNICAL DATA
1.
Reinstall DUST SEAL to LOWER HOUSING
(Figure 7)
.
2.
Using (2) screws provided, install UPPER HOUSING ASSEMBLY to the LOWER HOUSING
(Figure 7)
.
3.
With the flag in the “UP” position, reinstall FLAG PUSH ROD and set RESET ROD back into
place
(Figure 7)
.
4.
Set LOAD SPRING onto RESET ROD
(Figure 7)
.
5.
Install LID using two (2) screws provided
(Figure 7)
.
6.
Screw RESET BUTTON onto RESET ROD ensuring it turns freely
(Figure 7)
.
7.
Reinstall LIMIT SWITCH
8.
Push down on RESET BUTTON to fully extend PLUNGER into pipe bore. Put FLAG into
“DOWN” position
(Figure 7)
.
9.
Adjust MAIN ASSEMBLY by turning UPPER HOUSING clockwise or counter-clockwise to
attain INSTALL HEIGHT marked on TAG located on UPPER HOUSING ASSEMBLY
(Figure 8).
LOCK SCREW may need to be loosened.
NOTE:
See illustration for detailed drawing.
10.
Tighten LOCK SCREW to secure MAIN ASSEMBLY and slide DUST SEAL on to 2” NPT
ADAPTER
(Figure 9).
LSX Limit Switch - weather sealed, explosion proof enclosures meet
NEMA standards: 1, 3, 4, 6, 9 and 13. UL listed and CSA certified:
Class I, Div.1, Groups B,C and D. Class II, Div.1, Groups E, F and G.
Install Height Adjustment
Electrical Ratings
10 amps continuous carry. Circuits on any pole must be the same polarity.
AC Volts
Pilot Duty: 600VAC, 720VA
Electrical
Rating
Circuitry
VAC
Amps at 0.35
Power Factor
Make Break
Double Pole
Double Throw
120
240
480
600
30
15
7.5
6
3
1.5
0.75
0.60
B
DC Volts
Pilot Duty: 240VAC, 30 watts
Electrical
Rating
Circuitry
VDC
Make and Break Amps
Inductive Resistive
Double Pole
Double Throw
120
240
0.25
0.15
0.80
0.40
B
4L - Momentary
Double-pole, 2 N.O., 2 N.C.
ELectrical Rating B
1
2
3
4
5
6
7
8
IMPORTANT:
Detection of pig’s passage is dependent on
proper INSTALL HEIGHT. Incorrect INSTALL HEIGHT could void
the warranty.
Please Contact Apache for technical assistance
Phone: (780) 416-4850 Fax: (780) 416-4829 Email: [email protected]
Electrical Diagram
INSTALL
HEIGHT
INSTALLATION INSTRUCTIONS
Series 53 Visual/Electrical Indicator
with Manual/Auto Reset