Sep. 18
Automatikprodukter
Ozone Monitor, Temperature and Humidity
Modbus, Analog, Relay Outputs
1
db_ozone_wall_duct_ap_uk
O3
Technical Data
Gas Detected
Ozone - O
3
Sensing Element
Electrochemical gas sensor
Sensor lifetime
>2 years, removable and easy to
replace
Temperature Sensor
NTC 5K
Humidity Sensor
HS series capacitive sensor
Power Supply
24Vac/dc (power adaptor selectable)
Power Consumption
2.8W
Response Time
<50s @T90
Signal Update
1s
Warm up Time
<60 seconds
Ozone Measuring Range
0 to 5000ppb (0-5ppm)
(0 to 9.81mg/m
3
)
Display Resolution
0 to 1000ppb (0 to 1 ppm)
(0.01mg/m
3
)
1ppb (0,001ppm) (0,01mg/m
3
)
Accuracy
±0.01ppm + 10% reading
Nonlinear
<1%FS
Repeatability
<0.5%
Zero Drift
<1%
Sound
When LCD backlight is red the inner
buzzer alarm will be activated
Display, LCD backlight
Green - ozone level < 1500 ppb,
Yellow - 1500 ppb <ozone level
< 3500 ppb,
Red - 3500ppb < ozone level (default)
Temperature
measurement
-20 to 50
o
C (-4 to 140
o
F)
Humidity measurement
5 to 99% rH
Analog Output
0 to 10Vdc (default) or 4 to 20mA
linear output selectable
Analog Output Resolution
16Bit
Relay dry contact Output
Two dry-contact outputs
Max, switching current 3A
(220Vac/30Vdc), resistance Load
Features
-
Real time detection and monitoring ambiant ozone level
-
Design for real time detecting and monitoring ambiance
ozone level and temperature
-
Electrochemical ozone sensor with high sensitivity
-
Particular LCD display with three color backlights
(Green/
Yellow/Red)
-
Maximum ozone measuring range:
0 to 5000ppb (0 to 9.81mg/m
3
)
-
Enables reset of measurement range by end user
-
2 x On/Off dry contact outputs for two stages alarm
device,
or control a ozone generator or a ventilator
-
Buzzer alarm and 3-color backlight LCD indication
-
Preset two stage alarm points for ozone measurement
-
Provide 1 x analog output (0,2 to 10Vdc/4 to 20mA) (can be
used as transmitter)
-
Modbus RS485 communication interface, 15 kV antistatic
protection, individual IP address
-
Easy way for calibration and setup alarm
points via the RS
485 interface
-
Temperature measurement and display
-
Humidity measurement and display optional
-
Multiple application, wall mounting type and desktop type
-
Great performance with high quality
Ordering Codes
O3-5000
Ozone Monitor 0 - 5000ppb (0 - 5ppm), incl.
remote control, desktop bracket and power
supply.
O
3
Wall
O
3
Desktop
Application
-
Specially used for detecting indoor ambiance quality
-
Real time measuring ozone level and analyzing:
alarm when ozone level is over proof
, control ozone
concentrations by controlling related devices in order to reach
a certain level in some special places
-
Portable type for real time measuring and analyzing
-
Anti-epidemic and disease prevention, sanitary inspection,
environment protection, health protection, etc.
-
O3-5000 is the best device used to detect and analyze ozone
concentration.