background image

User Manual AW5145W

- 1 -

Wireless Temperature & Humidity

Transmitter

AW5145W User Manual

Содержание AW5145W

Страница 1: ...User Manual AW5145W 1 Wireless Temperature Humidity Transmitter AW5145W User Manual ...

Страница 2: ... range A TFT color display with high clarity has been provided displaying temperature and humidity values in real time The interior design has alarm function module which can achieve high low temperature alarm and high low wet alarm The AW5145W has WIFI signal output and the standard MODBUS TCP communication protocol with the maximum range of up to 50 meters It supports the installation of multi n...

Страница 3: ...ponse time 2 s 2 2 Temperature Parameter Condition Min Typ Max Units Resolution 0 1 Operating range 20 0 5 60 Drift Typical 0 1 yr Response time 2 s 2 3 Other specifications 1 Power consumption 50mA 24V 2 Supply voltage 9 36VDC USB 5V 3 Output signal 2 4G wireless WIFI IEEE802 11n 4 Communications protocol Standard MODBUS TCP 5 Storage Capacity 12800 points Maximum 6 Product Net Weight 125 79g ...

Страница 4: ...May 2017 4 3 Dimensions Figure 1 Dimension Units mm 4 Panel Schematic and Product Installation 4 1 Panel Schematic Figure 2 Panel schematic introduction Note 1 OK Key Enter 2 MENU Key Manual 3 UP Key UP Selection Antenna MENU OK UP DOWN Internal probe ...

Страница 5: ...e two M4 screws supplied in the attachment to fix on the wall 3 Hang the product on the wall The hanger is shown in figure 4 Figure 3 Plotting sheet fixing Figure 4 Fixing hanger 5 System Setup Menu Figure 5 Main interface symbol explanation 5 1 System Startup Interface After the power is turned on the system will start automatically After the system startup successfully the LCD will display tempe...

Страница 6: ...P address manually is used only when the IP address of the device need to be static 1 The steps to connect to the router by get IP address automatically mode are shown as follows 1 Long press the OK key to unlock the screen 2 Press MENU key to enter the setup menu select Net Setting press OK key to enter the submenu and select Router Config press OK key to enter the submenu and select Auto IP 3 Pr...

Страница 7: ...uration process the transmitter will prompt cancel configuration press the UP key or DOWN key to select Yes or No select YES and press OK key to cancel the configuration select NO and press OK key to continue configuration 2 The steps of obtaining SSID and password of router in set IP address Manually way to connect to the router are shown as follows 1 Long press the OK key to unlock the screen 2 ...

Страница 8: ...described above After setting enter the Start configuration option prompting Press OK to start configuration 4 Refer to the get IP address automatically mode Step 3 4 5 to configure 5 3 2 Communication Mode setting 1 Long press the OK key to unlock the screen 2 Press MENU key to enter the setting menu select Net Setting press OK key to enter the submenu and select Server Type press the UP key or D...

Страница 9: ...s OK key to enter Temperature HAR interface 3 Press the UP key or DOWN key to set the high temperature alarm value and alarm switch 5 4 2 Low Temperature Alarm Settings 1 Enter the setting menu select Alarm Setting press OK key to enter the submenu and select Temperature LAR then press OK key to enter Temperature LAR interface 2 Press the UP key or DOWN key to set the low temperature alarm value a...

Страница 10: ...y to select the other options to set Press MENU key to finish and return back 5 5 2 Upload Interval Setting Enter the Upload Interval menu press the OK key the Options that can be set switch between normal upload interval value units and alarm upload interval value Press the UP key or DOWN key to set the corresponding value Two kind of switchable units were minute and second 5 5 3 Record Setting 1...

Страница 11: ...pty and start recording from point 1 again 6 System Setting 6 1 Language Setting 1 Enter the System Setting menu and press OK to enter the submenu Select Language and press OK to enter the Language interface 2 Press the UP key or DOWN key to switch system language between Chinese and English 6 2 Temperature Units Setting 1 Enter the System Settings menu select Temperature Units and press OK to ent...

Страница 12: ...perature and Humidity Monitoring System software in the computer first Link http www aosong com cn downloads index asp The installation and setup steps are as follows 1 Download and install the Microsoft Corp NET2 0 support library If it is installed already no need to install again 2 Enter the company s official website download center and download the upper monitor software Temperature and Humid...

Страница 13: ...he internet 5 Transit mode related settings 1 Set the transmitter remote address to 14 23 92 147 and remote port to 9002 In the default situation it is no need to modify 2 Click on New Device button of the menu bar and new device dialog box pop up Select TCP network transit mode then enter the device access code and ID number The device access code is fixed to 12345678 and the device ID number can...

Страница 14: ...bar then scanning device dialog box pop up Select send UDP and click scan button The upper monitor software will scan the transmitter in the same network segment and wait for the scan to complete 7 After the scan complete click finish button and new devices will add to the system automatically The main interface pop up scan to the device list Click on the start button of the menu bar and the upper...

Страница 15: ...ecification in any form nor shall it be disclosed to a third party 2 The company and the third party have the ownership of the software and the user can only use it after signing the contract or obtaining the software license 3 The contents of this instruction manual are subject to change without prior notice 9 Warning and Personal Injury Do not apply this product to safety protection devices or e...

Страница 16: ...e free maintenance or replacement The user must meet the following conditions 1 The purchaser must notify the company of the defect in writing within 14 days of discovery 2 The purchaser shall pay the shipping charges for product mailed back to company 3 The product should be within the warranty period The company is solely responsible for products that are defective in situations where the techni...

Отзывы: