1 Product Appearance
1.1 Front Panel
LED_PWR
The green light will be on when the DC voltage of the internal power supply is within the normal
range (48 VDC ~ 52 VDC).
The green light will flash when the DC voltage of the internal power supply is out of the normal
range (48 VDC ~ 52 VDC).
The green light will be off when the external power supply is turned off, or the internal power
supply module does not work.
LED_RS485
The green light will stay on or flash when internal communication is normal.
The green light will stay constantly off when internal communication is abnormal.
LED_FWD
The blue light will be on when RF_OUT has power output.
The blue light will be off when the RF button is turned off, or the PA enters the auto-protection
mode and therefore shuts down its RF output. Several situations will result in auto-protection
mode, such as the input power is too high, the reflected power is too high, or the temperature is
too high.
LED_ALARM
The red light will be off if there is no alarm.
The red light will be on if there is an alarm.
LAN
Connector: 10M/100M Ethernet
Note: Ethernet port for web-based remote control (IP address: 192.168.1.200,
username/password: anywavecom/anywavecom)
RESET
Press for up to 8 seconds to reset the IP of the amplifier to default (192.168.1.200).