![Anybus CompactCom 40 EtherNet/IP Скачать руководство пользователя страница 149](http://html1.mh-extra.com/html/anybus/compactcom-40-ethernet-ip/compactcom-40-ethernet-ip_network-manual_2948758149.webp)
149
Doc.Id. HMSI-27-212
Anybus CompactCom 40 EtherNet/IP
Doc.Rev. 1.4
9.10 Functional Safety Module Object (11h)
Category
Extended
Object Description
This object contains information provided by the Safety Module connected to the Anybus Compact-
Com module. Please consult the manual for the Safety Module used, for values of the attributes below.
Supported Commands
Object:
Get_Attribute
Error_Confirmation
Instance:
Get_Attribute
Object Attributes (Instance #0)
Instance Attributes (Instance #1)
Extended
# Name
Access
Data Type
Value
1 Name
Get
Array of CHAR ‘Functional Safety Module’
2 Revision
Get
UINT8
01h
3 Number of instances
Get
UINT16
0001h
4 Highest instance no.
Get
UINT16
0001h
# Name
Acce
ss
Type
Description
1 State
Get
UINT8
Current state of the Safety Module
a
2 Vendor ID
Get
UINT16
Identifies vendor of the Safety Module.
E.g. 0001h (HMS Industrial Networks)
3 IO Channel ID
Get
UINT16
Describes the IO Channels that the Safety Module is
equipped with.
4 Firmware version
Get
Struct of
UINT8 (Major)
UINT8 (Minor)
UINT8 (Build)
Safety Module firmware version.
Version 2.18.3 would be represented as:
first byte: 02h
second byte: 12h
third byte: 03h
5 Serial number
Get
UINT32
32 bit number, assigned to the Safety Module at production.
6 Output data
Get
Array of UINT8
Current value of the Safety Module output data, i.e. data
FROM the network
Note: This data is unsafe, since it is provided by the Anybus
CompactCom module.