Installing a Bypass
It is recommended that an optional bypass
be installed to help with replacing cartridg-
es and servicing the system. Installation of
a bypass can be done easily as the Inlet and
Outlet Ball Valves are already installed.
1. Install tees on the end of the plumb-
ing leading to the Inlet and Outlet
Ball Valves.
2. Connect the two tees by installing
plumbing and a fully ported (prefer-
ably 3/4”) Ball Valve.
3. During system use, open the Inlet
and Outlet Ball Valves and close the
Bypass Ball Valve.
4. When performing service, close the
Inlet and Outlet Ball Valves and open
the Bypass Ball Valve.
Starting the Controller
1. Select the proper AC plug for your
electrical outlet and install it onto
the power supply.
2. Plug the appropriate end of the
power cord into the controller.
3. Plug the other end of the power cord
into the electrical outlet. The LEDs on
the controller turn on.
4. The controller automatically enters
Flush Mode and the Flush LED starts
to flash.
5. When flushing completes, the Flush
LED stops flashing and one or more
LEDs remains lit, indicating the unit
has power and which interval is
selected in the controller.
Rinsing the Ultra Filter Cartridge
The Ultra Filter Cartridge comes pre-in-
stalled in the VZN system.
NOTE:
Ultra Filter Cartridge must be
rinsed to drain before use. Rins-
ing to drain removes storage
solution and air. Do NOT rinse
into carbon if present. Carbon
life and/or performance may be
affected.
NOTE:
Make sure the Carbon Element,
if present, is NOT installed. These
should only be installed after the
Ultra Filter Cartridge has been
rinsed.
1. Direct water from the Rinse Ball Valve
to a drain.
2. Close the Outlet Ball Valve.
3. Close the Inlet Ball Valve.
4. Open the Rinse Ball Valve.
5. Slowly turn on the water supply to
the VZN system.
6. Slowly open the Inlet Ball Valve. Air
and water will come out of the Rinse
Ball Valve.
7. Press the FLUSH button. The Drain
Valve opens and air and water flows
out of the drain line. Repeat six times
to ensure all air and storage solution
are flushed out of the Ultra Filter
Cartridge.
8. Continue to allow water to run at full
flow out of the Rinse Ball Valve for at
least 15 minutes.
Water
Flow
Inlet Ball
Valve
(Manual)
Tee
Tee
Water
Flow
Outlet Ball
Valve
(Manual)
Fully
Ported
Ball Valve
9. After 15 minutes, close the Rinse Ball
Valve and allow the system to sit for
15 minutes without any water flow
to release any trapped air from the
Ultra Filter Cartridge.
10. Inspect the unit for any leaks, repair-
ing as needed.
11. After 15 minutes, open the Rinse Ball
Valve and wait for 15 more minutes
to flush out any remaining air.
12. Close the Rinse Ball Valve and dis-
connect the garden hose.
13. Press the FLUSH button to open
the Drain Valve. Repeat six times to
ensure any remaining air is flushed
out of the system.
14. Open the closest downstream tap or
faucet.
15. Slowly open the Outlet Ball Valve
and allow water to run through the
system and out the faucet for five
minutes.
Figure 7. Install Bypass