MSS-200 MINI SPATULA STEAMER
14
P/N 1010903 Rev. A 09/05
TROUBLESHOOTING (continued)
Problem
Possible Cause(s)
Corrective Action
Unit heats, does not steam,
but the green LED at the
rear of the unit DOES NOT
turn on for a spit second
as the Steam Switch is
pressed.
Faulty Steam Switch
Contact your maintenance person or an Authorized Service Agency
for service.
The generator surface
continuously fills with water
ONLY when the power
switch is OFF.
The solenoid valve is leaking due to
debris trapped within its plunger and
seat.
Attempt to flush the debris out by increasing the water regulator to 30
PSI & cycling the unit several times. Reset the regulator back to 7-9
PSI. If the problem persists. Contact the Authorized Service Agency
for service
The Solenoid Valve is not installed
correctly.
If the Solenoid Valve was replaced, verify that the “IN” and “OUT”
labels on the valve correspond to the water flow.
The generator surface
continuously fills with water
ONLY when the power
switch is turned ON.
Faulty temperature Control Board
Contact your maintenance person or an Authorized Service Agency
for service.
WIRING DIAGRAM
5
2
4
1
# 16 GA. TFE-200°C
UNLESS OTHERWISE SPECIFIED.
NOTE: ALL WIRES TO BE 14 GA. TFE-200°C
22 GA. TFE-200°C
GENERATOR
T4
T3
TEMP CONTROL
T1
T6
T5
SOLENOID
# BLK
THERMISTOR
GEN. RELAY
LED
ORG
ORG
SWITCH
T2
12VAC
120/240VAC
X-FORMER
J2
J4
J3
J1
HI-LIMIT
THERMOSTAT
BLOCK
#2
TERMINAL
BLK
# WHT
# BLK
4
3
WHT
POWER
SWITCH
GND
TERMINAL
POWER
BLOCK
CORD
MOMENTARY
#
BLK
#
WHT
# WHT
#
WHT
YLW
YLW
BLK
WHT
WHT