MAINTENANCE
Daily
1. Turn the Rocker Switch (power On/Off) to OFF.
Unplug the power cord and allow the unit to cool
down before proceeding.
2. Check the Water Pressure Regulator gauge and
verify that it reads 7- 9 PSI (0.4 - 0.6 kg/cm2
or 48-62 kPa). If not, adjust the water pressure
as described in the Installation section of this
manual. Check the rear water Quick Disconnect
Fitting and Hose Clamp for leakage. If leakage is
apparent, tighten the hose clamp first. If leakage
persists, replace the small black O-Ring on the
Quick Disconnect.
NOTE: Three (3) spare O-Rings are attached to the
Quick Disconnect #1 (Figure 5). Additional O-Rings
can be obtained by ordering part number 020P117
(10 pack).
3. Remove the Spatula, Top Cover, and Diffuser.
(Figure 9).
NOTE: To remove the Top Cover, carefully bend one
side so that the cover slot releases from the
vent. Do not bend the cover more than it takes to
remove it
4. Wash these items in hot, soapy water and then
rinse and
WIPE DRY
.
5. Wipe down the entire exterior of the unit (Figure
5) with a clean, hot, damp cloth (not dripping wet)
and wipe dry.
6. Reinstall the Diffuser, Top Cover, and Spatula.
NOTE: Failure to properly clean and dry the above
mentioned items prior to reassembly may result in
the accumulation of water/moisture overnight. This
may lead to permanent damage of the equipment’s
finish and its accessories. This damage is not cov-
ered by warranty.
Monthly
The MSS-200 Mini Spatula Steamer utilizes an open
steam generator. Water sprayed onto the generator
surface flashes into steam immediately, but the miner-
als in the water do not steam, they stay on the genera-
tor surface.
A small amount of calcium/mineral deposits are
needed for proper operation
, but a build-up of exces-
sive calcium/mineral deposits causes poor steaming
efficiency, excessive moisture (wet steam) and will
eventually severely retard the steaming action com-
pletely.
5. Pour delimer solution (not supplied) onto the gen-
erator surface. Follow the delimer manufacturer’s
instructions for proper mixture and use.
6. Using a sponge or a dry towel, remove the
delimer solution from the generator surface, then
rinse with clean water.
NOTE: To ensure proper steaming characteristics,
some calcium/mineral deposits must be present on
the generator surface. If, during cleaning, the sur-
face does become free of calcium/mineral deposits,
add plain tap water to the surface and allow it to
boil off. If necessary, repeat this process to formu-
late a thin coating of calcium/mineral deposits.
NOTE: In soft water areas, it may be necessary
to add a small amount of lime to the generator to
“season” it. This will ensure proper steaming char-
acteristics by producing a thin coating of calcium/
mineral deposits on the generator surface.
Seasoning mixture consists of 3/4 ounces (25ml/
25cc) baking soda, 3/4 ounces (25ml/25cc) lime
mixed with 1 quart (950ml/950cc) of water. Stir
mixture and pour 1/4” deep onto the hot generator
surface. After mixture is converted to steam, the
remaining loose power can be removed.
7. Plug the power cord into the appropriate outlet.
Turn the Rocker Switch (power On/Off) to ON.
Allow the unit to warm up for about 30 minutes.
8. Cycle the unit several times to operate the steam-
er.
This purges any remaining delimer residue
from the generator surface.
9. Turn the unit off, reinstall all parts and accesso-
ries, and return the unit to service.
CLEANING STEAM GENERATOR
1. Turn the unit off and unplug the power cord.
Allow the unit to cool down before proceeding.
2. Perform the Daily cleaning, but
DO NOT
reas-
semble the unit
4. With the unit cool, use a wire brush and/or
scraper to loosen and remove the excessive cal-
cium/mineral deposits from the generator surface
(Figure 5). Remove the loose build up, wipe the
generator with a clean, damp cloth.
NOTE: If deposits are still excessive and/or diffi-
cult to remove, refer to Steps 5 and 9.