background image

HEBT-3V BUN TOASTER

14

P/N 1011328 Rev. I   04/18 

McDonald’s

TROUBLESHOOTING

Problem

Possible Cause

Corrective Action

Control Display flashes 

Err 5 

continuously. Buns 

not toasting properly.

The A Platen temperature has not 

reached the setpoint temperature 

within 20 minutes.

Allow the unit to warm up for 30 minutes and then 

recheck. If the Control Display still flashes 

Err 5

contact your maintenance person or Authorized 

Service Agency for service.

Failed A Platen Thermocouple.

Contact your maintenance person or Authorized 

Service Agency for service.

Failed Control Board

Control Display flashes 

Err14

 continuously. 

Buns not toasting prop-

erly.

The B Platen temperature has not 

reached the setpoint temperature 

within 20 minutes.

Allow the unit to warm up for 30 minutes and then 

recheck. If the Control Display still reads 

Err 14

contact your maintenance person or Authorized 

Service Agency for service.

Failed Rear Platen Thermocouple.

Contact your maintenance person or Authorized 

Service Agency for service.

Failed Control Board.

Control Display flashes 

Err 9

 continuously.

Control Compartment ambient tem-

perature is above 150

°

 F (66

°

 C)

Verify side vents on toaster are unblocked and not 

near other heating appliances. If problem persists, 

contact your maintenance person or Authorized 

Service Agency for service.

Failed Cooling Fan.
Failed Control Board

Control Display Flashes 

Err 19

 continuously. 

Buns Burn.

Failed A Platen Solid State Relay.

Contact your maintenance person or Authorized 

Service Agency for service.

Failed Control Board.
Failed A Platen Thermocouple.

Control Display flashes 

Err 18

 continuously. 

Buns Burn.

Failed B Platen Solid State Relay.

Contact your maintenance person or Authorized 

Service Agency for service.

Failed Control Board.
Failed B Platen Thermocouple.

Control Display flashes 

Err 13 

continuously. 

Buns not toasting prop-

erly.

Loose A Platen Thermocouple con-

nection on Control Board or the 

Front Platen Thermocouple is open.

Re-secure the A Platen Thermocouple to the 

Control Board. If the Control Display still reads 

Er 

13

, check the front Thermocouple for continuity. 

Contact your maintenance person or Authorized 

Service Agency for service.

Failed Control Board.

Control Display flashes 

Err 11

 continuously. 

Buns not toasting prop-

erly.

Loose B Platen Thermocouple con-

nection on Control Board or the 

Rear Platen thermocouple is open.

Re-secure the B Platen Thermocouple connection 

to the Control Board. If the Control Display still 

reads 

Er 11

, check the Rear Thermocouple for 

continuity. Contact your maintenance person or 

Authorized Service Agency for service.

Failed Control Board.

Control Display flashes 

Err 12 

continuously. 

Buns not toasting prop-

erly.

Shorted A Platen Thermocouple to 

ground.

Disconnect and re-secure the A Platen 

Thermocouple connection to the Control Board. 

If the Control Display still reads 

Er 12

, check 

the Rear Thermocouple for continuity. Contact 

your maintenance person or Authorized Service 

Agency for service.

Failed Control Board

Control Display Flashes 

Err 10

 continuously. 

Buns not toasting.

Shorted B Platen Thermocouple to 

ground.

Re-secure the B Platen Thermocouple connection 

to the Control Board. If the Control Display still 

reads 

Er 10

, check the Rear Thermocouple for 

continuity. Contact your maintenance person or 

Authorized Service Agency for service.

Failed Control Board.

Содержание HEBT-3V

Страница 1: ...the period of this warranty A J Antunes Co will pay labor costs to an Authorized Service Agent to replace the part plus travel expenses A J Antunes Co reserves the right to make changes in design or add improvements on any products The right is always reserved to modify Equipment because of factors beyond our control and government regulation Changes to Equipment do not constitute a warranty charg...

Страница 2: ... a claim Freight damage claims are the responsibility of the purchaser and are not covered under warranty The warranty does NOT extend to Damages caused in shipment or damage as result of improper use Installation of electrical service Normal maintenance as outlined in this manual Malfunction resulting from improper maintenance Damage caused by abuse or careless handling Damage from moisture into ...

Страница 3: ...l codes and any other applicable codes 24 93 633 1 mm 25 73 653 5 mm 15 30 388 5 mm Dimensions Electrical Specifications Plug Configuration Model Mfg No Volt Watts Hz Plug Description Plug Configuration HEBT 3V 9210858 208 3300 50 60 L6 30P 30 Amp 250 Volt Straight Twist Lock HEBT 3V 9210865 250 3300 50 60 L6 30P 30 Amp 250 Volt Straight Twist Lock ...

Страница 4: ...uipment should be grounded according to local electrical codes to prevent the possibility of electrical shock It requires a grounded recep tacle with separate electrical lines protected by fuses or circuit breaker of the proper rating Bread may burn Therefore toasters must not be used near or below curtains or other combustible walls and materials Failure to maintain safe operating distances may c...

Страница 5: ... It contains HEBT 3V toaster Accessories box 2 Remove the accessories box from the large box 3 With the help of another person carefully remove the HEBT 3V from the large box 4 Remove all protective coverings from the unit 5 Open the Accessories Box It contains Owner s Manual Bun Buffer Frame 6 Wipe the entire exterior of the toaster and the accessories mentioned above with a clean towel sprayed w...

Страница 6: ...ten Heater 3 Press the PROGRAM button to proceed to the Front Platen Heater menu The display shows the actual temperature of the Front Platen 4 Press the LIGHTER button to toggle between the setpoint and actual temperature of the Front Platen 5 Press the PROGRAM button to proceed to the Motor Menu The display shows the actual speed of the motor 6 Press the LIGHTER button to toggle between the setp...

Страница 7: ...rotective caps 3 Press and release both buttons Reinstall the pro tective caps NOTE If the Hi Limit Controls require continuous resetting contact your Authorized Service Agency Purging buns from Toaster If buns get stuck in the toaster press and hold both the UP and DOWN arrow buttons to increase the belt speed until the buns are purged from the toaster There are variations in bun products Worldwi...

Страница 8: ...here is heavy carbon buildup on the conveyor belt 6 Inspect the rear belts for any tears discoloration or damage to the Belt Wrap snaps Replace any damaged Belt Wrap as needed With proper maintenance the Crown and Main Belt Wraps can six months or longer Refer to PR 68 Q1 and PR 68 Q2 for belt replacement instructions 7 If the rear belt is in good condition spray a clean damp sanitized towel with ...

Страница 9: ...HEBT 3V BUN TOASTER 9 P N 1011328 Rev I 04 18 McDonald s Figure 3 Examples of Damaged Belts MAINTENANCE continued ...

Страница 10: ...28 Rev I 04 18 McDonald s MAINTENANCE continued Figure 4 Example of Damaged Belt BELT IS TORN AND FOLDED REPLACE BELT BELT IS MISSING SNAPS AND IS DAMAGED REPLACE BELT Figure 5 Example of Damaged Belt Figure 6 Example of Damaged Belt ...

Страница 11: ...d screwdriver and open the panel Set the bun compression knob to 7 6 Push down on the front and rear belt rollers and move them away from the center of the toaster Use both hands This removes tension and locks the rollers in place 7 Lift the upper belt frame lock Then rotate down so it rests on the camshaft of the rear belt roller 8 Pull down the lower belt frame lock This provides access to the f...

Страница 12: ...ttom roller Make sure the belt lines up properly on the rollers The snaps on the belts should face the inside of the roller 4 Lift up the front and rear belt roller Use both hands This will add tension and lock them in place 5 Lift the lower conveyor lock to lock the rollers into place NOTE Lift up on the camshaft of the rear conveyor roller while lifting the conveyor lock 6 Lift the upper belt fr...

Страница 13: ...d debris Clean out all crumbs and debris using a clean dry towel or nylon bristled brush Be careful not to disrupt any of the electrical wiring 5 Slowly close the control housing cover Reconnect with the screws 6 Remove the screws from the bottom plate on the rear of the unit and slowly lower the cover 7 Remove any debris or dust from the cooling fan with a small brush Wipe away any debris with a ...

Страница 14: ...ontrol Display flashes Err 18 continuously Buns Burn Failed B Platen Solid State Relay Contact your maintenance person or Authorized Service Agency for service Failed Control Board Failed B Platen Thermocouple Control Display flashes Err 13 continuously Buns not toasting prop erly Loose A Platen Thermocouple con nection on Control Board or the Front Platen Thermocouple is open Re secure the A Plat...

Страница 15: ...t positions of the shafts as described in the Maintenance section of this manual Either both Upper Lower Conveyor locks are not properly locked in place Inspect the proper position of the locks as described in the Maintenance section of this manual Compression side door will not close Either both Upper Lower Conveyor Locks are not properly locked in place Inspect the proper position of the locks a...

Страница 16: ...cuit Breakers If they trip again check the Power Cord Plug and outlet for damage Contact your maintenance person Authorized Service Agency and Electrician for service Faulty Transformer Replace Transformer Conveyors not turning Motor Drive Chain is detached from sprockets Reinstall the Drive Chain Drive Chain needs lubrication Lubricate Drive Chain with Lubit 8 P N 2140152 Failed Drive Motor Conta...

Страница 17: ...HEBT 3V BUN TOASTER 17 P N 1011328 Rev I 04 18 McDonald s REPLACEMENT PARTS 80 118 104 105 85 118 23 18 34 24 23 24 ...

Страница 18: ...R 18 P N 1011328 Rev I 04 18 McDonald s REPLACEMENT PARTS continued 73 119 77 149 95 92 133 92 110 110 120 120 82 81 92 133 97 149 155 148 108 99 100 157 126 92 157 122 111 148 157 126 16 122 37 37 20 26 124 101 156 122 ...

Страница 19: ...HEBT 3V BUN TOASTER 19 P N 1011328 Rev I 04 18 McDonald s REPLACEMENT PARTS continued 84 138 88 87 138 138 83 83 162 47 103 153 86 147 106 102 153 91 142 162 89 136 169 170 171 ...

Страница 20: ...HEBT 3V BUN TOASTER 20 P N 1011328 Rev I 04 18 McDonald s REPLACEMENT PARTS continued 48 52 51 50 50 64 63 61 60 59 146 166 62 141 165 161 145 158 160 160 152 107 146 54 167 168 ...

Страница 21: ...v I 04 18 McDonald s REPLACEMENT PARTS continued 68 151 66 70 69 134 14 9 11 132 132 125 149 8 92 133 6 2 90 96 3 15 13 156 148 144 135 109 109 151 94 133 92 82 110 110 93 81 120 120 93 71 108 156 111 25 25 159 141 41 46 146 45 42 148 150 ...

Страница 22: ...192 Adj Platen Assembly 1 48 0013181 Relay Sink Bracket Assy 1 49 0507247 Heat Sink Relay 1 50 3080157 Screw Tap 8 32 X 3 8 Lg 4 51 4010187 Transformer 240 Vac 12Vac 1 52 4050240 Relay Solid State Dual Pole 1 W Conn Recept 53 0013193 Control Cover Assembly 1 54 0022110 Weldment Control Housing Cover 1 55 1000900 Label Warning 1 56 1001213 Label Shock Hazard 1 57 1001434 Label Thermocouple 1 58 100...

Страница 23: ...oove S S 8 134 2150324 Chain Drive 1 Item Part No Description Qty Item Part No Description Qty REPLACEMENT PARTS continued 135 2150362 Cam Hbcs 2 136 2150406 Cam Shaft 1 137 300P102 Nut Speed 8 32 U 1 138 300P123 Ring Retaining External 1 139 304P105 Nut Hex Keps 4 40 1 140 306P104 Screw Mach 6 32 X 1 4 1 141 306P130 Nut Hex Keps 6 32 Small Pattern 1 142 308P102 Washer Int Tooth 8 1 143 308P124 Sc...

Страница 24: ...HEBT 3V BUN TOASTER 24 P N 1011328 Rev I 04 18 McDonald s WIRING DIAGRAM ...

Страница 25: ...HEBT 3V BUN TOASTER 25 P N 1011328 Rev I 04 18 McDonald s NOTES ...

Страница 26: ...HEBT 3V BUN TOASTER 26 P N 1011328 Rev I 04 18 McDonald s NOTES ...

Страница 27: ...HEBT 3V BUN TOASTER 27 P N 1011328 Rev I 04 18 McDonald s NOTES ...

Страница 28: ......

Отзывы: