background image

RESIDENTIAL VZN

2

P/N 1011586 Rev A 07/20

®

Contents

Introduction 2

Before Use 

2

In Case of Damage 

2

Service/Technical Assistance 

2

Safety Information 

3

Installation 3

Operation 3

Maintenance 3

Service 3

Safety Information (Continued) 

4

Specifications 

5

Performance Data Sheet 

6

Filter Cartridge Capacities 

6

Performance Claims 

6

Overview 7

Manual Flushing 

7

Unpacking 8

Equipment Setup 

8

General 

8

Electrical 

8

Plumbing 

8

Installation Tools and Supplies 

8

Installation 9

Mounting the System 

9

Alternative Vertical Mounting 

9

Drain Valve Connection 

10

System Inlet Connection 

11

Permeate Outlet Connection 

11

Inlet Water Plumbing 

11

Installing a Bypass 

12

Starting the Controller 

12

Rinsing the UltraFilter Cartridge 

12

Sanitizing the System and Lines 

13

Maintenance 14

Replacing the UltraFilter Cartridge  14

Changing the Interval Setting 

15

Resetting the Timer Program 

15

Semi-Annual Task 

15

Permeate Tank Air Pre-Charge 

15

Troubleshooting 16

Replacement Parts 

17

Parts List 

17

Exploded View 

18

Notes 19

Limited Warranty 

20

Introduction

The VZN system is an innovative filtration 

system that uses proprietary multi-bore 

hollow fiber membranes as well as a 

carbon element to provide the latest 

innovation in filtration technology.

Before Use

This manual provides the safety, 

installation, and operating procedures 

for the VZN water filtration system. All 

information contained in this manual 

should be read prior to installing and 

operating the system.  Your VZN 

system is manufactured from the finest 

materials available and is assembled 

to strict quality standards. This system 

has been tested at the factory to ensure 

dependable trouble-free operation. 

In Case of Damage

If the unit arrives damaged, contact 

Antunes Customer Service at 

 

+1-877-392-7856. Save all packing 

materials when filing a claim. 

Service/Technical 

Assistance

If there are any problems with the 

installation or operation of the unit, 

contact Antunes Technical Service at 

 

+1-877-392-7854 (toll free).
Fill in this information and have it handy 

when calling for assistance. The serial 

number is on the specification plate 

located on the unit.

IMPORTANT

Antunes reserves the right to change 

specifications and product design 

without notice. Such revisions DO 

NOT entitle the buyer to corresponding 

changes, improvements, additions or 

replacements for previously purchased 

equipment.

IMPORTANT

Keep these instructions for future 

reference. If the system changes  

ownership, be sure this manual 

accompanies the equipment. 

Purchased from

Date of purchase

Model number

Serial number

Manufacturing number

Suggested replacement period for 

the UltraFilter Cartridge is 3 years 

(dependent on water quality).

 

For sales in the state of Iowa:

Seller

Date

Buyer

Date 

 

 

Содержание 9720002

Страница 1: ...uction Class I Standard No 53 Health Effects Cyst Reduction Turbidity Reduction as verified and substantiated by test data Owner s Manual Original Instructions Residential Water Filtration Manufacturing Numbers 9720002 9720007 VZN 520H VZN 540H www antuneswater com CAUTION Read all instructions before using the unit Original Instructions P N 1011586 Rev A 07 20 ...

Страница 2: ...nual provides the safety installation and operating procedures for the VZN water filtration system All information contained in this manual should be read prior to installing and operating the system Your VZN system is manufactured from the finest materials available and is assembled to strict quality standards This system has been tested at the factory to ensure dependable trouble free operation ...

Страница 3: ... suitably sized booster system outlet pressure 60 psig 100 psig max 414 kPa 690 kPa max be installed WARNING ELECTRICAL SHOCK HAZARD Failure to follow the instructions in this manual could result in serious injury or death DO NOT modify the power supply cord plug If it does not fit the outlet have a proper outlet installed by a qualified electrician DO NOT use an extension cord with this unit If t...

Страница 4: ...portation and installation Protect from organic solvents and concentrated acids Prevent any and all contact of the membrane with strong solvents solvents containing chlorine or concentrated acids DO NOT use strong solvents or concentrated acids on any plastic parts of the filter system Examples of some solvents to avoid acetone methyl acetate nail polish remover hexane spot removers turpentine tol...

Страница 5: ...Plug Configurations Kit Model Number Description Configuration Kit 0012146 DC Power Supply 100 240 VAC Includes the 4 plug adaptors below US NEMA 1 15 2 pin or NEMA 5 15 3 Pin Euro CEE 7 16 AS NZS 3112 AUS 2 Pin UK BS 1363 NOTE Includes plug adaptors for US Europe Australia and UK NOTE PLUG STYLE MAY VARY US NEMA 1 15 2 PIN or NEMA 5 15 3 PIN EURO CEE 7 16 AS NZS 3112 2 PIN AUS BS 1363 UK UK Repla...

Страница 6: ...SF ANSI 42 or 53 While testing was performed under standard laboratory conditions actual performance may vary DO NOT use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts Performance Data Sheet Filter Cartridge Capacities ...

Страница 7: ...ed water will continue to be filtered but the system will NOT flush This could cause the UltraFilter to plug prematurely and may reduce the life of the filter Manual Flushing A manual flush can be activated at any time by pressing the FLUSH button on the Universal Pulse Controller When the FLUSH button is pressed the Flush LED on the controller flashes and the Drain Valve opens for 10 seconds Afte...

Страница 8: ...a switched electrical outlet Plumbing NOTE The system must be connected to the COLD water line DO NOT connect the system to the hot water line The VZN system uses the following connections System Inlet 3 4 FNPT System Outlet Product Water 3 4 FNPT Drain 3 4 FNPT When making a plumbing connection to the system use a back up wrench on the supporting plumbing Always use a quality approved pipe sealan...

Страница 9: ...is located at the TOP Figure 2A 3 Allow sufficient access for cartridge replacement VZN 420 units should be mounted with 20 inches above or below VZN 440 units should be mounted with 40 inches above or below Figure 2 Mounting the System A 32 31 31 20 28 36 21 22 23 35 23 22 21 39 39 39 39 39 32 39 39 INLET ENDCAP ASSEMBLY 43 DETAIL A SCALE 1 2 SEE DETAIL B FOR INSTALLATION DETAIL OF ITEMS 21 22 AN...

Страница 10: ...n lines the use of an O Ring sealed union is recommended not supplied When connecting the drain hose pay attention to the following guidelines y The drain line plumbing must be able support the flow rate whenever the system flushes This flow rate is dependent on the inlet water pressure inlet pipe size and system y The drain line leading out of the system must be as short as possible and slope dow...

Страница 11: ...ed Water Permeate Outlet Connection The System Outlet has a 3 4 NPT thread at the Outlet Figure 5 DO NOT overtighten fittings as this could cause the plastic to crack Use plastic fittings and a pipe thread sealant approved for use on PVC fittings when making connections Inlet Water Plumbing Before connecting the fitting to the System Inlet the plumbing to the system must be flushed clear of all de...

Страница 12: ... system The UltraFilter Cartridge must be rinsed before the system is used to remove any air and protective solution NOTE UltraFilter Cartridge must be rinsed to drain before use Rinsing to drain removes storage solution and air DO NOT rinse into carbon if present Carbon life and or performance may be affected 1 Close the Inlet Ball Valve 2 Direct water from the outlet to a drain 3 Open the Outlet...

Страница 13: ...supplied 1 Follow the steps in the Rinsing the UltraFilter Cartridge in the Installation section of this manual 2 Turn off the water to the system 3 Open the faucet or tap closest downstream to the system 4 Allow the system and plumbing to drain 5 Allow the water to drain out of the system 6 Pour the sanitizer into the water line supplying the system fitting using a cup or funnel Be sure to wear p...

Страница 14: ...erial number of the new cartridge The cartridge serial number is engraved on one end of the outer tube for example 05K 12013 9 Lubricate all O rings with a food grade silicone lubricant Apply a light coating of lubricant to the inside center tube at both ends of the new cartridge 10 Position the new cartridge into the housing and gently insert into the housing 11 Ensure the cartridge is fully seat...

Страница 15: ...On On Figure 8 Universal Pulse Controller Semi Annual Task Check Permeate Tank Air Pre Charge It is recommended the permeate tank air charge be checked every six months Caution Air pre charge should only be checked and adjusted under zero system pressure The system must be depressurized before checking the tank pre charge DO NOT adjust the tank air pre charge with the system under pressure Caution...

Страница 16: ... or replace the outlet check valve assembly The inlet flow restrictor may be plugged Clean or replace the inlet flow restrictor Water tastes bad Storage shipping solution not completely rinsed out of the system Rinse the system for a longer period of time replace Carbon Element Biological growth in pipes Sanitize plumbing Water condition changed Consider installing additional filtration Broken cap...

Страница 17: ...ble Tie 36 Black 2 14 7002017 Rubber Cradle Kit 2 15 3000132 Nut Cage 8 32 ZP Steel 2 16 0508910 Housing 4 DIA X 20 L SS 304 UF 1 0508919 Housing 4 DIA x 40 L SS 304 UF 1 17 7002014 VZN UFL Drain Endcap Kit 1 18 7002015 Clamp Kit Endcap 2 19 7001914 SS Housing O Ring Kit 2 20 0700769 Wire Harness GAP 421 Valve Not Shown 1 21 2190210 Fitting 3 4 MPT X 3 4 CTS STEM JG 2 22 2170173 Valve Ball 3 4 CTS...

Страница 18: ...RESIDENTIAL VZN 18 P N 1011586 Rev A 07 20 Exploded View VZN 520H and VZN 540H Systems 8 15 8 8 15 8 3 1 2 13 5 14 4 6 10 25 11 12 21 11 10 18 24 13 14 7 7 19 22 23 18 17 19 16 21 9 26 26 26 26 ...

Страница 19: ...RESIDENTIAL VZN 19 P N 1011586 Rev A 07 20 Notes ...

Страница 20: ...r to placing of the equipment into service 2 Antunes reserves the right to make changes in design or add any improvements on any product The right is always reserved to modify equipment because of factors beyond our control and government regulations Changes to update equipment DO NOT constitute a warranty charge 3 THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPL...

Отзывы: