background image

VZN T5 SERIES

22

P/N 1011115 Rev. J 04/17

REPLACEMENT PARTS (continued)

VZN-421HC-T5 Systems

VZN-441HC-T5 Systems

Replacement Parts can be purchased from an authorized dealer. Contact  

A.J. Antunes & Co. at 1-630-754-1000 or toll free in the United States at 1-800-253-2991.

 Item  Part 

Description 

Qty. 

   No.

 Item  Part 

Description 

Qty. 

   No.

 Item  Part 

Description 

Qty. 

   No.

 Item  Part 

Description 

Qty. 

   No.

1  0505873  VZN Back Plate 

1

2  0012357  Universal Pulse Controller 

1

4060438

  36" Black Cable Tie 

2

7000921

  Permeate Tank Replacement Kit 

1

5  0400381  Grommet, 1.75" OD x 1.197" ID 

1

2190158

  Female Connector, 3/4" CTS x 3/4" NPT 1

2010199

  Tubing, Bent 90° 

1

2180181

  Lock Ring 

2

9  2180230  End Cap 4" Quick Disconnect 

2

10 

7000413

  O-ring Replacement Kit 

1

11 

2180201

  Ultra Filter Housing 420 

1

12 

2070117

  Nipple, Close 3/4" NPT 

1

13 

7000411

  Ultra Filter Cartridge Replacement Kit  1 

 

 

(Incl. #10)

14 

2170131

  Ball Valve, 3/4" Female to 3/4" Male 

3

15 

2190171

  Nipple Reducer Hex, 1" to 3/4"  

1

16 

2180287

  UFL Housing Clamp 

2

17 

3000116

  Nut Retainer, 1/4"-20 

4

18 

3250154

  Washer, Lock 1/4" 

4

19  3250109  Screw, 1/4"-20 x 1/2" 

4

20 

2010198

  Tubing, UFL Bent 180° 

2

21 

2190155

  Union Tee 

2

22 

2010200

  Tubing, UFL 

1

23  2010176  Tubing, Bent 90° 

1

24 

2190189

  Adaptor, Tube to 1" NPT 

2

25 

2180220

  Carbon Element/TAC-05 Head 

2

26 

2180290

  Check Valve Bushing 

1

27 

2170127

  Check Valve Insert 

1

28 

2180281

  Outlet Adaptor, Machined 

1

29 

2170128

  PSI Pressure Gauge 

1

30 

2180283

  Carbon Element Housing 

1

31  3080213  Screw, 1/4"-15 x 3/4" 

8

32 

4040189

  Solenoid Valve, NC 3/4" NPT 

1

33 

7000762

  Chloramine Carbon Element  

 

 

Replacement Kit 

34  0505871  VZN Mounting Bracket 

35 

2190154

  Adaptor, 1" Stem 

1

36 

2180255

  TAC-05 Housing and O-Ring 

1

37 

7000554

  TAC-05 Cartridge Kit 

1

38  0021667  Flow Regulator Assy., 7.9 gpm 

1

39  0012146  Power Adaptor Assy. 

1

40 

2190184

  Tee, PVC, 3/4 NPT (not shown) 

1

41  2190135  Plug, Nylon, 3/4" NPT (not shown) 

1

1  0505873  VZN Back Plate 

1

2  0012357  Universal Pulse Controller 

1

4060438

  36" Black Cable Tie 

2

7000921

  Permeate Tank Replacement Kit 

1

5  0400381  Grommet, 1.75" OD x 1.197" ID 

1

2190158

  Female Connector, 3/4" CTS x 3/4" NPT 1

2010199

  Tubing, Bent 90° 

1

2180181

  Lock Ring 

2

9  2180230  End Cap 4" Quick Disconnect 

2

10 

7000413

  O-ring Replacement Kit 

1

11 

2180202

  Ultra Filter Housing 440 

1

12 

2070117

  Nipple, Close 3/4" NPT 

1

13 

7000412

  Ultra Filter Cartridge Replacement Kit  1 

 

 

(Incl. #10)

14 

2170131

  Ball Valve, 3/4" Female to 3/4" Male 

3

15 

2190171

  Nipple Reducer Hex, 1" to 3/4"  

1

16 

2180287

  UFL Housing Clamp 

2

17 

3000116

  Nut Retainer, 1/4"-20 

4

18 

3250154

  Washer, Lock 1/4" 

4

19  3250109  Screw, 1/4"-20 x 1/2" 

4

20 

2010197

  Tubing, UFL Bent 180° 

2

21 

2190155

  Union Tee 

2

22 

2010200

  Tubing, UFL 

1

23  2010176  Tubing, Bent 90° 

1

24 

2190189

  Adaptor, Tube to 1" NPT 

2

25 

2180220

  Carbon Element/TAC-05 Head 

2

26 

2180290

  Check Valve Bushing 

1

27 

2170127

  Check Valve Insert 

1

28 

2180281

  Outlet Adaptor, Machined 

1

29 

2170128

  PSI Pressure Gauge 

1

30 

2180282

  Carbon Element Housing 

1

31  3080213  Screw, 1/4"-15 x 3/4" 

8

32 

4040189

  Solenoid Valve, NC 3/4" NPT 

1

33 

7000762

  Chloramine Carbon Element  

 

 

Replacement Kit 

34  0505871  VZN Mounting Bracket 

1

35 

2190154

  Adaptor, 1" Stem 

1

36 

2180255

  TAC-05 Housing and O-Ring 

1

37 

7000554

  TAC-05 Cartridge Kit 

1

38  0021666  Flow Regulator Assy., 15 gpm 

1

39  0012146  Power Adaptor Assy. 

1

40 

2190184

  Tee, PVC, 3/4 NPT (not shown) 

1

41  2190135  Plug, Nylon, 3/4" NPT (not shown) 

1

Содержание 9700771

Страница 1: ...d Certified by NSF International and WQA against NSF ANSI Standard 42 and 53 for the reduction of Standard No 42 Aesthetic Effects Nominal Particulate Reduction Class I Standard No 53 Health Effects Cyst Reduction Turbidity Reduction as verified and substantiated by test data System Tested and Certified by WQA against NSF ANSI Standard 372 for lead free compliance ...

Страница 2: ...ent or damage as result of improper use Installation of electrical service Normal maintenance as outlined in this manual Malfunction resulting from improper maintenance Damage from moisture leaking into electrical components Damage from tampering with removal of or changing any preset control or safety device Owner Information 2 General 2 Warranty Information 2 Service Technical Assistance 3 Impor...

Страница 3: ...it handy when calling for assistance The serial number is on the specification plate located on the system OWNER INFORMATION continued IMPORTANT A J Antunes and Company reserves the right to change specifications and product design without notice Such revisions do NOT entitle the buyer to corresponding changes improvements additions or replacements for previously purchased equipment Suggested repl...

Страница 4: ...All electrical connections must be in accordance with local electrical codes and any other applicable codes WARNING ELECTRICAL SHOCK HAZARD FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN SERIOUS INJURY OR DEATH Do NOT modify the power supply cord plug If it does not fit the outlet have a proper outlet installed by a qualified electrician Do NOT use an extension cord with this unit If the sup...

Страница 5: ...leaning solutions insecticides Protect from abrasive material The membranes must be protected from abrasive materials like shavings left in a pipe Abrasive materials in contact with the membrane can cause irreversible damage to the mem brane All pipes must be flushed clean before installing the fil ter All plastic parts of the filter system must be protected from sharp objects like knives sand pap...

Страница 6: ...3 100 240 10 08 50 60 CAUTION All electrical connections must be in accordance with local electrical codes and any other applicable codes A ground fault circuit interrupter GFCI must be installed on the circuit to this system When installed on metallic plumbing a properly sized electrical bonding jumper must be installed across the inlet and outlet pipes serving this unit Electrical Cord Plug Conf...

Страница 7: ... NOTE The NSF WQA information provided applies to the Ultra Filter cartridge Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system Systems certified for cyst reduction may be used on disinfected waters that may contain fil terable cysts Filter Cartridge Capacities Maximum Operating Pressure 100 psig 690 kPa Maximum Ope...

Страница 8: ...ller to last 10 seconds and take place in one hour intervals This interval can be changed see Changing the Interval Setting in the Maintenance section of this manual Manual Flushing A manual flush can be activated at any time by pressing the FLUSH button on the Universal Pulse Controller When the FLUSH button is pressed the Flush LED on the controller flashes and the Drain Valve opens for 10 secon...

Страница 9: ...riate outlet Do NOT connect the system to a switched electrical outlet PLUMBING NOTE The system must be connected to the COLD water line Do NOT connect the system to the hot water line The VZN system uses the following connections System Inlet 3 4 NPT System Outlet Product Water 3 4 NPT Drain 3 4 FNPT Rinse Outlet 3 4 Garden Hose or 3 4 ID Hose When making a plumbing connection to the system use a...

Страница 10: ... the system to the wall Some of the bottom mount ing holes may be obscured Plan your mounting accordingly INSTALLATION continued Follow these steps to secure the Mounting Bracket to the wall and seat the VZN system 1 Use a stud finder and level to attach the Mounting Bracket securely to the wall with the appropriate mounting hardware Figure 2 2 The Mounting Bracket is designed so that the VZN syst...

Страница 11: ...is flow rate is dependent on the inlet water pressure inlet pipe size and system The drain line leading out of the system must be as short as possible and slope downwards without any kinks or loops The drain line plumbing must be positioned and secured at least 2 inches above the drain Figure 4 This air gap protects the system from contamination in the event of a backed up drain The drain used mus...

Страница 12: ...meate Outlet Connection The System Outlet has a 3 4 NPT male thread at the Outlet Valve Figure 6 Do NOT overtighten fittings as this could cause the plastic ball valve to crack Use plastic fittings and a pipe thread sealant approved for use on PVC fittings when making connections 3 4 Garden Hose Connection 3 4 Garden Hose not supplied directed to drain Rinse Valve Connection Inlet Ball Valve Manua...

Страница 13: ... The Drain Valve will open and air and water will come out of the drain line Repeat six times to ensure all air and storage solution are flushed out of the Ultra Filter Cartridge 8 Continue to allow water to run at full flow out of the Rinse Ball Valve for at least 15 minutes 9 After 15 minutes close the Rinse Ball Valve and allow the system to sit for 15 minutes without any water flow to release ...

Страница 14: ... the system until the presence of sanitizer is gone 14 Open all other faucets and taps in line with the system to flush any remaining sanitizer from the plumbing 15 Close all faucets and taps Rinsing the Carbon Element and TAC Cartridge The Carbon Element and TAC Cartridge MUST be rinsed before using the system the first time and immediately after the Carbon Element or TAC Cartridge have been repl...

Страница 15: ...ight coating of lubricant to the inside cen ter tube at both ends of the new cartridge 10 Record the serial number of the new cartridge The cartridge serial number is engraved on one end of the outer tube for example 05K 12013 11 Install the End Cap O ring on the End Cap and insert the Large End Cap into the end of the new cartridge 12 Position the new cartridge and End Cap at the housing and gent...

Страница 16: ...ng NOTE Make sure the Gasket remains in place in the recessed grooves on both ends of the Carbon Element 9 Screw the Carbon Element Housing containing the Carbon Element into place on the Carbon Element Head The Housing will come to a hard stop at the end of the thread Use a Filter Wrench if necessary NOTE Do NOT overtighten the Carbon Element Housing 10 Direct water from the Rinse Ball Valve to a...

Страница 17: ...d The Housing will come to a hard stop at the end of the thread Use a Filter Wrench if necessary 10 Direct water from the Rinse Ball Valve to drain NOTE It is important to direct the Rinse Ball Valve to a drain as the water resulting from the flush should NOT be used 11 Turn on the water to the system by slowly open ing the Inlet Ball Valve and allow water to flow through the TAC Cartridge and Hou...

Страница 18: ...D will also turn on Figure 12 Universal Pulse Controller Semi Annual Tasks Check Permeate Tank Air Pre Charge It is recommended the permeate tank air charge be checked every six months Tools and supplies required Air Pressure Gauge 5 40 psi range 0 3 2 7 bar with tire valve Schrader Valve connection CAUTION Air pre charge should only be checked and adjusted under zero system pressure The system mu...

Страница 19: ...r replace the outlet check valve assembly The inlet flow restrictor may be plugged Clean or replace the inlet flow restrictor Water tastes bad Carbon Element need replacing Replace Carbon Element Storage shipping solution not completely rinsed out of the system Rinse the system for a longer period of time replace Carbon Element Biological growth in pipes Sanitize plumbing Water condition changed C...

Страница 20: ...5 SERIES 20 P N 1011115 Rev J 04 17 REPLACEMENT PARTS 30 36 37 33 25 25 1 2 39 3 31 12 28 20 14 14 29 16 32 38 14 15 19 4 5 6 7 8 9 11 17 21 13 26 27 18 20 21 22 23 24 24 35 9 8 10 10 34 VZN 421HC T5 Systems ...

Страница 21: ...IES 21 P N 1011115 Rev J 04 17 30 33 25 1 2 3 31 34 12 20 16 32 14 15 19 4 5 6 7 8 9 11 17 21 13 18 20 21 22 23 24 9 8 10 10 36 37 25 28 14 14 29 26 27 24 35 39 38 REPLACEMENT PARTS continued VZN 441HC T5 Systems ...

Страница 22: ...it 34 0505871 VZN Mounting Bracket 1 35 2190154 Adaptor 1 Stem 1 36 2180255 TAC 05 Housing and O Ring 1 37 7000554 TAC 05 Cartridge Kit 1 38 0021667 Flow Regulator Assy 7 9 gpm 1 39 0012146 Power Adaptor Assy 1 40 2190184 Tee PVC 3 4 NPT not shown 1 41 2190135 Plug Nylon 3 4 NPT not shown 1 1 0505873 VZN Back Plate 1 2 0012357 Universal Pulse Controller 1 3 4060438 36 Black Cable Tie 2 4 7000921 P...

Страница 23: ...VZN T5 SERIES 23 P N 1011115 Rev J 04 17 NOTES ...

Страница 24: ...n or regular adjustments as specified in operating and maintenance instructions of this manual and or labor involved in moving adjacent objects to gain access to the Equipment 2 A J Antunes Co reserves the right to make changes in design or add any improvements on any product The right is always reserved to modify equipment because of factors beyond our control and government regulations Changes t...

Отзывы: