Antunes 9700770 Скачать руководство пользователя страница 1

P/N 1011114 Rev. J  04/17

Water Filtration System

owner’s manual

Model VZN-421HC - VZN-441HC

Manufacturing Numbers:

9700770 & 9700772

www.antunes.com

System Tested and Certified by NSF 

International and WQA against NSF/ANSI

Standard 42 and 53 for the reduction of:

Standard No. 42: Aesthetic Effects 

Nominal Particulate Reduction Class I

Standard No. 53: Health Effects

Cyst Reduction & Turbidity Reduction as 

verified and substantiated by test data.

System Tested and Certified by WQA

against NSF/ANSI Standard 372 

for lead-free compliance

Содержание 9700770

Страница 1: ...ertified by NSF International and WQA against NSF ANSI Standard 42 and 53 for the reduction of Standard No 42 Aesthetic Effects Nominal Particulate Reduction Class I Standard No 53 Health Effects Cyst Reduction Turbidity Reduction as verified and substantiated by test data System Tested and Certified by WQA against NSF ANSI Standard 372 for lead free compliance ...

Страница 2: ...to Damages caused in shipment or damage as result of improper use Installation of electrical service Normal maintenance as outlined in this manual Malfunction resulting from improper maintenance Damage from moisture leaking into electrical components Damage from tampering with removal of or changing any preset control or safety device Owner Information 2 General 2 Warranty Information 2 Service Te...

Страница 3: ... handy when calling for assistance The serial number is on the specification plate located on the system OWNER INFORMATION continued IMPORTANT A J Antunes and Company reserves the right to change specifications and product design without notice Such revisions do NOT entitle the buyer to corresponding changes improvements additions or replacements for previously purchased equipment Suggested replac...

Страница 4: ...ll electrical connections must be in accordance with local electrical codes and any other applicable codes WARNING ELECTRICAL SHOCK HAZARD FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN SERIOUS INJURY OR DEATH Do NOT modify the power supply cord plug If it does not fit the outlet have a proper outlet installed by a qualified electrician Do NOT use an extension cord with this unit If the supp...

Страница 5: ...n in temperature The maximum operating temperature is 100 F 38 C Avoid abrupt variations in temperature Any temperature variation should be made slowly Protect from rough handling or dropping Mechanical damage external breakage and or internal break age of the filter can result if the system is dropped or bumped Handle with care at all times during transportation and instal lation Protect from org...

Страница 6: ...daptors for US Europe Australia and UK Tested and verified by independent laboratory testing Electrical Cord Plug Configurations Kit Model Number Description Configuration 0012146 DC Power Supply 100 240 VAC Includes the 4 plug adaptors below NOTE PLUG STYLE MAY VARY US NEMA 1 15 2 pin or NEMA 5 15 3 Pin US NEMA 1 15 2 PIN or NEMA 5 15 3 PIN Euro CEE 7 16 EURO CEE 7 16 AS NZS 3112 AUS 2 Pin AS NZS...

Страница 7: ...s NOTE The NSF WQA information provided applies to the Ultra Filter cartridge Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system Systems certified for cyst reduction may be used on disinfected waters that may contain fil terable cysts Filter Cartridge Capacities Maximum Operating Pressure 100 psig 690 kPa Maximum Op...

Страница 8: ...se Controller to last 10 seconds and take place in one hour intervals This interval can be changed see Changing the Interval Setting in the Maintenance section of this manual Manual Flushing A manual flush can be activated at any time by pressing the FLUSH button on the Universal Pulse Controller When the FLUSH button is pressed the Flush LED on the controller flashes and the Drain Valve opens for...

Страница 9: ...utlet Do NOT connect the system to a switched electrical outlet PLUMBING NOTE The system must be connected to the COLD water line Do NOT connect the system to the hot water line The VZN system uses the following connections System Inlet 3 4 NPT System Outlet Product Water 3 4 NPT Drain 3 4 FNPT Rinse Outlet 3 4 Garden Hose or 3 4 ID Hose When making a plumbing connection to the system use a back u...

Страница 10: ...re assembled to a Back Plate The Back Plate has mounting holes across the bottom portion to secure the INSTALLATION continued bottom of the system to the wall Some of the bottom mount ing holes may be obscured Plan your mounting accordingly Follow these steps to secure the Mounting Bracket to the wall and seat the VZN system 1 Use a stud finder and level to attach the Mounting Bracket securely to ...

Страница 11: ... flow rate is dependent on the inlet water pressure inlet pipe size and system The drain line leading out of the system must be as short as possible and slope downwards without any kinks or loops The drain line plumbing must be positioned and secured at least 2 inches above the drain Figure 4 This air gap protects the system from contamination in the event of a backed up drain The drain used must ...

Страница 12: ... Fitting with plug supplied should be installed at the System Inlet This fitting will be used for sanitizing the system and downstream plumbing Figure 6a Before connecting the fitting to the System Inlet the plumb ing to the system must be flushed clear of all debris Hold a bucket at the inlet water line and slowly open the Inlet Water Valve Allow the pipe to flush until all debris is removed Filt...

Страница 13: ...he Drain Valve will open and air and water will come out of the drain line Repeat six times to ensure all air and storage solution are flushed out of the Ultra Filter Cartridge 8 Continue to allow water to run at full flow out of the Rinse Ball Valve for at least 15 minutes 9 After 15 minutes close the Rinse Ball Valve and allow the system to sit for 15 minutes without any water flow to release an...

Страница 14: ...may have occurred during the installation process One ounce 30 ml of liquid chlorine bleach regular bleach unscented 5 25 6 sodium hypochlorite or Kay 5 sanitizer solution Sodium Dichloro s Triazinetrione Dihydrate 6 or equivalent can be used to sanitize the plumbing The Kay 5 sanitizer solution is made by dissolving a 1 oz packet of Kay 5 powder in 2 oz 60 ml of clean warm water This can be done ...

Страница 15: ...oating of lubricant to the inside center tube at both ends of the new cartridge 9 Record the serial number of the new cartridge The cartridge serial number is engraved on one end of the outer tube for example 05K 12013 10 Install the End Cap O ring on the End Cap and insert the Large End Cap into the end of the new cartridge 11 Position the new cartridge and End Cap at the housing and gently inser...

Страница 16: ...he end of the thread Use a Filter Wrench if necessary NOTE Do NOT overtighten the Carbon Element Housing 10 Direct water from the Rinse Ball Valve to a drain NOTE Direct the Rinse Ball Valve to a drain Do NOT use the water resulting from the flush procedure 11 Open the Rinse Ball Valve Turn on the water to the system by slowly opening the Inlet Ball Valve Allow water to flow through the Carbon Ele...

Страница 17: ...will also turn on Figure 10 Universal Pulse Controller Semi Annual Tasks Check Permeate Tank Air Pre Charge It is recommended the permeate tank air charge be checked every six months Tools and supplies required Air Pressure Gauge 5 40 psi range 0 3 2 7 bar with tire valve Schrader Valve connection CAUTION Air pre charge should only be checked and adjusted under zero system pressure The system must...

Страница 18: ...may be plugged Clean or replace the inlet flow restrictor Water tastes bad Carbon Element need replacing Replace Carbon Element Storage shipping solution not completely rinsed out of the system Rinse the system for a longer period of time replace Carbon Element Biological growth in pipes Sanitize plumbing Water condition changed Consider installing additional filtration Broken capillaries in Ultra...

Страница 19: ...VZN SERIES 19 P N 1011114 Rev J 0417 REPLACEMENT PARTS 30 33 25 1 2 36 3 31 12 28 20 14 14 29 16 32 35 14 15 19 4 5 6 7 8 9 11 17 21 13 26 27 18 20 21 22 23 24 9 8 10 10 34 VZN 421HC Systems ...

Страница 20: ...VZN SERIES 20 P N 1011114 Rev J 04 17 30 33 25 1 2 3 31 34 12 28 20 14 14 29 16 32 14 15 19 4 5 6 7 8 9 11 17 21 13 26 27 18 20 21 22 23 24 9 8 10 10 36 35 REPLACEMENT PARTS continued VZN 441HC Systems ...

Страница 21: ... 4 4 32 4040189 Solenoid Valve NC 3 4 NPT 1 33 7000762 Chloramine Carbon Element 1 Replacement Kit 34 0505871 VZN Mounting Bracket 1 35 0021667 Flow Regulator Assy 7 9 gpm 1 36 0012146 Power Adaptor Assy 37 37 2190184 Tee PVC 3 4 NPT not shown 1 38 2190135 Plug Nylon 3 4 NPT not shown 1 1 0505870 VZN Back Plate 1 2 0012357 Universal Pulse Controller 1 3 4060438 36 Black Cable Tie 2 4 7000921 Perme...

Страница 22: ...VZN SERIES 22 P N 1011114 Rev J 04 17 NOTES ...

Страница 23: ...VZN SERIES 23 P N 1011114 Rev J 0417 NOTES ...

Страница 24: ...n or regular adjustments as specified in operating and maintenance instructions of this manual and or labor involved in moving adjacent objects to gain access to the Equipment 2 A J Antunes Co reserves the right to make changes in design or add any improvements on any product The right is always reserved to modify equipment because of factors beyond our control and government regulations Changes t...

Отзывы: