Water Filtration System

owner’s manual

Model VZN-441 & VZN-441V-TS

Manufacturing Numbers:

9700741 & 9700751

System Tested and Certified by NSF 

International against NSF/ANSI

Standard 42 and 53 for the reduction of:

Standard No. 42: Aesthetic Effects 

Nominal Particulate Reduction Class I

Standard No. 53: Health Effects

Cyst Reduction & Turbidity Reduction as 

verified and substantiated by test data.

System Tested and Certified

against NSF/ANSI Standard 372 

for lead-free compliance

Original Instructions 
www.antunes.com

Содержание 9700741

Страница 1: ...mbers 9700741 9700751 System Tested and Certified by NSF International against NSF ANSI Standard 42 and 53 for the reduction of Standard No 42 Aesthetic Effects Nominal Particulate Reduction Class I Standard No 53 Health Effects Cyst Reduction Turbidity Reduction as verified and substantiated by test data System Tested and Certified against NSF ANSI Standard 372 for lead free compliance Original I...

Страница 2: ... Check Permeate Tank Air Pre Charge 18 Troubleshooting 19 Replacement Parts 20 Notes 23 Limited Warranty 24 General The VZN system is an innovative filtration system that uses proprietary multi bore hollow fiber membranes as well as a carbon element to provide the latest innovation in filtration technology This manual provides the safety installation and operating procedures for the VZN water filt...

Страница 3: ...ext column and have it handy when calling for assistance The serial number is on the specification plate located on the system OWNER INFORMATION continued IMPORTANT Antunes reserves the right to change specifications and product design without notice Such revisions do NOT entitle the buyer to corresponding changes improvements additions or replacements for previously purchased equipment Suggested ...

Страница 4: ... electrical connections must be in accordance with local electrical codes and any other applicable codes WARNING ELECTRICALSHOCK HAZARD FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN SERIOUS INJURY OR DEATH Do NOT modify the power supply cord plug If it does not fit the outlet have a proper outlet installed by a qualified electrician Do NOT use an extension cord with this unit If the supply ...

Страница 5: ...tion in temperature The maximum operating temperature is 100 F 38 C Avoid abrupt variations in temperature Any temperature variation should be made slowly Protect from rough handling or dropping Mechanical damage external breakage and or internal breakage of the filter can result if the system is dropped or bumped Handle with care at all times during transportation and installation Protect from or...

Страница 6: ...100 240 10 08 50 60 VZN 441V T5 9700751 100 240 10 08 50 60 Electrical Cord Plug Configurations Kit Model Number Description Configuration 0012146 DC Power Supply 100 240 VAC Includes the 4 plug adaptors below NOTE PLUG STYLE MAY VARY US NEMA 1 15 2 pin or NEMA 5 15 3 Pin US NEMA 1 15 2 PIN or NEMA 5 15 3 PIN Euro CEE 7 16 EURO CEE 7 16 AS NZS 3112 AUS 2 Pin AS NZS 3112 2 PIN AUS UK BS 1363 BS 136...

Страница 7: ...sted below The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system as specified in NSF ANSI 42 or 53 While testing was per formed under standard laboratory conditions actual perfor mance may vary NOTE The NSF information provided applies to the Ultra Filter cartridge Do not us...

Страница 8: ...and cleans the Ultra Filter membrane by removing any debris collecting on the membrane wall The Drain Valve is only powered during Flush Mode NOTE Do NOT unplug the power cord or turn off the sys tem during Flush Mode If there is a power outage or the system is unplugged water will continue to be filtered but the system will NOT flush This could cause the Ultra Filter to plug prematurely and may r...

Страница 9: ... on the power cord must match the appropriate outlet Do NOT connect the system to a switched electrical outlet PLUMBING NOTE The system must be connected to the COLD water line Do NOT connect the system to the hot water line The VZN system uses the following connections System Inlet 3 4 NPT System Outlet Product Water 3 4 NPT Drain 3 4 FNPT Rinse Outlet 3 4 Garden Hose or 3 4 ID Hose When making a...

Страница 10: ...ottom mount ing holes may be obscured Plan your mounting accordingly Follow these steps to secure the Mounting Bracket to the wall and seat the VZN system 1 Use a stud finder and level to attach the Mounting Bracket securely to the wall with the appropriate mounting hardware Figure 2 2 The Mounting Bracket is designed so that the VZN system can be lifted and hung on the Mounting Bracket With assis...

Страница 11: ...is flow rate is dependent on the inlet water pressure inlet pipe size and system The drain line leading out of the system must be as short as possible and slope downwards without any kinks or loops The drain line plumbing must be positioned and secured at least 2 inches above the drain Figure 4 This air gap protects the system from contamination in the event of a backed up drain The drain used mus...

Страница 12: ... Inlet has a 3 4 NPT male thread at the Inlet Valve Figure 6 Do NOT overtighten fittings as this could cause the plastic ball valve to crack Use plastic fittings and a pipe thread sealant approved for use on PVC fittings when making connections Filtered Water Permeate Outlet Connection The System Outlet has a 3 4 NPT female thread at the Outlet Valve Figure 6 Do NOT overtighten fittings as this co...

Страница 13: ... wait for 15 more minutes to flush out any remaining air 12 Close the Rinse Ball Valve and disconnect the garden hose 13 Press the FLUSH button to open the Drain Valve Repeat six times to ensure any remaining air is flushed out of the system 14 Open the closest downstream tap or faucet 15 Slowly open the Outlet Ball Valve and allow water to run through the system and out the faucet for five minute...

Страница 14: ...open the Inlet Valve Allow the pipe to flush until all debris is removed Sanitizing the System and Lines The plumbing must be sanitized to eliminate possible contam ination that may have occurred during the installation process One ounce 30 ml of liquid chlorine bleach regular bleach unscented 5 25 6 sodium hypochlorite or Kay 5 sanitizer solution Sodium Dichloro s Triazinetrione Dihydrate 6 or eq...

Страница 15: ...ight coating of lubricant to the inside cen ter tube at both ends of the new cartridge 10 Record the serial number of the new cartridge The cartridge serial number is engraved on one end of the outer tube for example 05K 12013 11 Install the End Cap O ring on the End Cap and insert the Large End Cap into the end of the new cartridge 12 Position the new cartridge and End Cap at the housing and gent...

Страница 16: ...ining the Carbon Element into place on the Carbon Element Head The Housing will come to a hard stop at the end of the thread Use a Filter Wrench if necessary NOTE Do NOT overtighten the Carbon Element Housing 10 Direct water from the Rinse Ball Valve to a drain NOTE Direct the Rinse Ball Valve to a drain Do NOT use the water resulting from the flush procedure 11 Open the Rinse Ball Valve Turn on t...

Страница 17: ...g if it is cracked twisted or missing 7 Lubricate the O ring with an approved food grade lubricant and install into the TAC Housing 8 Install the new TAC Cartridge into the TAC Hous ing with the arrow on the cartridge pointing up NOTE Make sure the End Seal gaskets are in place in the recessed grooves on both ends of the TAC Cartridge Figure 4 9 Screw the TAC Housing containing the TAC Car tridge ...

Страница 18: ...ed 4 The permeate tank should have a pressure of 28 31 PSI To add pressure to the permeate tank use a manual bicycle tire pump or other source of compressed air To release pressure from the permeate tank press the center pin on the air inlet valve 5 Once the permeate tank is at 28 31 PSI replace the protective cap on the air valve 6 Pressurize system by closing the Rinse Valve and opening the Inle...

Страница 19: ...defective Clean or replace the outlet check valve assembly The inlet flow restrictor may be plugged Clean or replace the inlet flow restrictor Water tastes bad Carbon Element need replacing Replace Carbon Element Storage shipping solution not completely rinsed out of the system Rinse the system for a longer period of time replace Carbon Element Biological growth in pipes Sanitize plumbing Water co...

Страница 20: ...VZN V SERIES 20 P N 1011079 Rev L 07 19 REPLACEMENT PARTS 2 35 3 31 16 11 4 5 6 7 7 8 9 10 13 19 17 18 23 23 22 34 15 36 32 12 14 30 33 25 24 28 14 20 21 14 29 26 27 8 9 10 1 VZN 441V Systems ...

Страница 21: ...IES 21 P N 1011079 Rev L 07 19 2 35 3 31 16 11 4 5 6 7 7 8 9 10 13 19 17 18 23 23 22 34 15 39 32 12 14 30 33 25 24 36 37 25 28 14 20 21 14 29 26 27 24 38 8 9 10 1 REPLACEMENT PARTS continued VZN 441V T5 Systems ...

Страница 22: ... 36 2180255 TAC 05 Housing and O Ring 1 37 7000554 TAC 05 Cartridge Kit 1 38 2190154 Adaptor 1 Stem 1 39 0021666 Flow Regulator Assy 15 gpm 1 40 0700769 Wiring Harness not shown 1 41 2190184 Tee PVC 3 4 NPT not shown 1 42 2190135 Plug Nylon 3 4 NPT not shown 1 VZN 441V Systems Item Part Description Qty No Item Part Description Qty No 1 0505886 VZN Back Plate 1 2 0012357 Universal Pulse Controller ...

Страница 23: ...VZN V SERIES 23 P N 1011079 Rev L 07 19 NOTES ...

Страница 24: ...tion or regular adjustments as specified in operating and maintenance instructions of this manual and or labor involved in moving adjacent objects to gain access to the Equipment 2 Antunes reserves the right to make changes in design or add any improvements on any product The right is always reserved to modify equipment because of factors beyond our control and government regulations Changes to up...