background image

P/N 1010698 Rev. E 03/04

TACO BELL STEAMER

Models TBS-1X & TBS-2X

Owner

s Manual

MANUFACTURING

NUMBERS:

9100400

9100402

9100410

9100412

A

S

D

L I S T E

��

O

I N

NIT A T

T

I S

L

��

E D

Содержание TBS-1X

Страница 1: ...P N 1010698 Rev E 03 04 TACO BELL STEAMER Models TBS 1X TBS 2X Owner s Manual MANUFACTURING NUMBERS 9100400 9100402 9100410 9100412 A S D L I S T E O I N NIT A T T I S L E D ...

Страница 2: ...under warranty OWNER INFORMATION TABLE OF CONTENTS The warranty does not extend to Damages caused in shipment or damage as result of improper use Installation of electrical service Installation of plumbing or water supply or water pressure regulator if applicable Calibration adjustment or maintenance Normal maintenance as outlined in this manual Consumable parts such as gaskets rubber feet labels ...

Страница 3: ...and fill in the information below Authorized Service Agency Name Phone No Address Use only genuine Roundup replacement parts in this unit Use of replacement parts other than those sup plied by the manufacturer will void the warranty Your Authorized Service Agency has been factory trained and has a complete supply of parts for this unit You may contact the factory at 1 877 392 7854 or 1 630 784 100...

Страница 4: ... locate the equipment only for its intend ed use as described in this manual Do not use corrosive chemicals in this equipment Do not operate this equipment if it has a dam aged cord or plug if it is not working properly or if it has been damaged or dropped This equipment should be serviced by qualified personnel only Contact the nearest Authorized Service Agency for adjustment or repair Do not blo...

Страница 5: ...ter jet Do not use a sanitizing solution or abrasive materials The use of these may cause dam age to the stainless steel finish To ensure proper steaming characteristics some mineral deposits must be present on generator surface If during cleaning the surface does become free of mineral deposits add plain tap water to surface and allow it boil off This will ensure proper steaming char acteristics ...

Страница 6: ...on this appliance Do not modify the power supply cord plug If it does not fit the outlet have a proper outlet installed by a qualified electrician Do not use an extension cord with this appli ance Check with a qualified electrician if you are in doubt as to whether the appliance is properly grounded Electrical Cord Plug Configurations Dimensions Letter Code Description Configuration C Commercial C...

Страница 7: ...se 6 Assemble the handle and handle guard to the spatula s as shown in Figure 1 7 Re install spatula s Equipment Setup GENERAL When placing the unit into service pay attention to the following guidelines Make sure power to the unit is off and the unit is at room temperature Do not block or cover any openings on the unit Do not immerse cord or plug in water Keep cord away from heated surfaces Do no...

Страница 8: ...N OF THIS MANUAL BEFORE PERFORMING ANY OF THESE STEPS CAUTION Water pressure must not exceed 30 psi 2 1 kg cm2 or 207 kPa Higher water pressures may cause poor performance or flooding To reduce water pressure install a water pressure regula tor and set water pressure between 20 30 psi 1 4 2 1 kg cm2 or 138 207 kPa To order a water pressure regulator from your authorized service center order Roundu...

Страница 9: ...blespoons of water to be disbursed onto the Generator Surface for steaming Since the Generator has an oval cover that is secured in place with a wing nut the steam is forced downward throught the Generator steam ports and onto the product The Control Board incorporates several LEDs for status and diagnostic purposes See LED Layout in the Operation section of this manual An audio signal will sound ...

Страница 10: ... fully into the steamer 5 Press and release the Cycle Start button The green Ready light will go out and the yellow Steaming light will come on and remain lit for the entire steaming cycle 6 At the end of the steaming cycle approximately 7 seconds an audible signal will sound for 3 sec onds and the green Ready light will come back on These signals inform the operator that the product is ready for ...

Страница 11: ...ing agents e g bleach sanitizers degreasers or detergents could cause permanent damage to stainless steel equipment The damage is usually in the form of discoloration dulling of metal surface finish pits voids holes or cracks This damage is permanent and not covered by warranty The following tips are recommended for maintenance of your stain less steel equipment Always use soft damp cloth for clea...

Страница 12: ...Generator Cover 10 Clean Steam Chamber free of any product spills 11 Clean unit surface with a hot clean damp cloth not dripping wet and wipe dry 12 Re install all parts and fasten the generator cover IMPORTANT To ensure proper steaming charac teristics some mineral deposits must be present on generator surface If during cleaning the sur face does become free of mineral deposits bare aluminum add ...

Страница 13: ...eps 7 9 until the proper amount of water level in the cup is achieved NOTE If steamer does not steam properly after calibration refer to the Troubleshooting section of this manual NOTE If calibration kit is missing use the Calibration Chart Figure 8 to figure approxi mate volume Turn the water volume control to 0 Determine your water pressure and locate it on the chart left side then look to the r...

Страница 14: ...ction of this manual Generator Steam Ports are restricted Verify that the Steam Ports are not restricted Clean accordingly Generator surface is bare Generator surface must have a thin calcium coating for proper steaming Refer to the Maintenance section of this manual Unit heats but does not steam Low or no water pressure in water line Remove the Quick Disconnect Insert from the rear of the unit Wh...

Страница 15: ...nerator fails test Solid State Relay not closing Verify that there is 7 10 VDC on relay terminals 3 4 If present check for line voltage across relay terminals 1 and 2 If present replace the relay Control Board inoperable or problematic Verify that there is 7 10 VDC on terminals T5 T3 If not present replace the Control Board Loose burnt or broken wires in heater circuit Repair or replace wires Circ...

Страница 16: ...ood and also prevents excessive and or fluctuation water pressure from interfering with the equipment s proper and consistent operation The 7000134 Regulator Kit consists of the following items Ref Part No Description Qty 1 0503849 Bracket 1 2 2040130 Male Adapter Barbed 1 4 2 3 2090127 Strainer 1 4 NPT 1 4 2170113 Regulator Pressure 1 5 2170114 Gauge Water Pressure 1 6 2190129 Nipple 1 4 NPT x 1 ...

Страница 17: ...17 TACO BELL STEAMER TBS 2X TBS 1X P N 1010698 Rev E 03 04 REPLACEMENT PARTS ...

Страница 18: ...male 1 2 29 7000139 Connector Quick Disconnect Male 1 2 30 405K125 Relay Solid State 1 2 31 4050180 Heat Sink 1 2 32 0700452 Power Cord 1 2 33 040K251 Strain Relief 1 2 35 0021133 Chimney 1 1 0021136 Chimney 1 1 36 0700554 Wire Set not shown 1 2 37 7000136 Terminal Block Kit 1 2 Includes 38 50 51 38 100P967 Label Marking 1 2 39 2040146 Tee Female 1 2 40 2040145 Elbow Female 1 2 41 7000319 Transfor...

Страница 19: ...19 TACO BELL STEAMER TBS 2X TBS 1X P N 1010698 Rev E 03 04 NOTES ...

Страница 20: ...or all other countries If the Melter is carried into an Authorized Service Agency it will be repaired subject to the terms of the Limited Warranty at no charge for parts and labor If you request the Authorized Service Agency to service the Melter at your store the store must pay any charges above and beyond the SHOP labor rate for that Service Agency including travel mileage charges 2 Roundup rese...

Отзывы: