background image

Variety Steamer

 

Models VS-200aSb & adb

Owner

s manual

P/N 1010649 Rev. E 03/07

MaNufactuRiNg

NuMbERs:

9100210 

9100212 

9100218 

9100220 

9100222 

9100224 

9100230

A

S

D

L I S T E

CM

O

I N

NIT A T

C

T

I S

L

US

E D

Содержание Roundup VS-200ADB

Страница 1: ...ariety Steamer Models VS 200asb adb Owner s Manual P N 1010649 Rev E 03 07 Manufacturing Numbers 9100210 9100212 9100218 9100220 9100222 9100224 9100230 A S D L I S T E CM O I N NIT A T C T I S L US E D ...

Страница 2: ...n this manual If the unit arrives damaged contact the carrier imme diately and file a damage claim with them Save all packing materials when filing a claim Freight damage claims are the responsibility of the purchaser and are not covered under warranty The warranty does not extend to Damages caused in shipment or damage as result of improper use Installation of electrical service Normal maintenanc...

Страница 3: ...s on the specification plate located on the rear of the unit Purchased From Date of Purchase Model No Serial No Mfg No Refer to the service agency directory and fill in the information below Authorized Service Agency Name Phone No Address Use only genuine Roundup replacement parts in this unit Use of replacement parts other than those sup plied by the manufacturer will void the warranty Your Autho...

Страница 4: ...e equipment only for its intend ed use as described in this manual Do not use corrosive chemicals in this equipment Do not operate this equipment if it has a dam aged cord or plug if it is not working properly or if it has been damaged or dropped This equipment should be serviced by qualified personnel only Contact the nearest Roundup authorized service facility for adjustment or repair Do not blo...

Страница 5: ...essure regulator and set water pressure between 20 25 psi 1 4 1 7 kg cm2 or 138 172 kPa To order a water pressure regula tor from your authorized service center order Roundup part no 7000314 Do not clean this appliance with a water jet Do not use a sanitizing solution or abrasive materials The use of these may cause dam age to the stainless steel finish To ensure proper steaming characteristics so...

Страница 6: ...EADY STEAM Model Mfg No Voltage Watts Amps Hertz VS 200ASB 9100210 208 240 3800 18 3 15 8 50 60 VS 200ASB 9100212 230 3490 15 2 50 60 VS 200ADB 9100218 240 3000 12 5 50 60 VS 200ADB 9100220 208 240 3800 18 3 15 8 50 60 VS 200ADB 9100222 230 3490 15 2 50 60 VS 200ADB 9100224 240 3800 15 8 50 60 VS 200A 9100230 208 240 3800 18 3 15 8 50 60 Model Mfg No Description Configuration VS 200ASB 9100212 910...

Страница 7: ... parts Installation Figure 1 Variety Steamer Caution All electrical connections must be in accordance with local electrical codes and any other appli cable codes Equipment Setup General When placing the unit into service pay attention to the following guidelines Make sure power to the unit is off and the unit is at room temperature Do not block or cover any openings on the unit Do not immerse cord...

Страница 8: ... Gauge If should read 20 PSI If it reads more or less adjust the pressure by pulling the black knob upwards and turning it clockwise to increase counter clockwise to decrease the water pres sure Push the knob down to lock it in place NOTE When adjusting the knob you must relieve the existing pressure by pressing the White plastic tip on the Quick Disconnect insert for 3 sec onds The gauge will now...

Страница 9: ...ESCRIPTION DIAL SETTING TIME PreCooked Items VS 200 VS 350 Frozen Items VS 200 VS 350 Spaghetti 3 25 seconds Mixed Vegetables 6 55 seconds Rice 3 25 seconds Spaghetti 6 55 seconds Egg Noodles 3 25 seconds Ravioli 12 1 minute 55 seconds Macaroni 3 25 seconds Tortellini 12 1 minute 55 seconds Ravioli 6 55 seconds Other Tortellini 6 55 seconds Poached Eggs 18 2 minutes 45 seconds Roast Beef Sliced 2 ...

Страница 10: ...approximately 3 4 oz 25 milliliters of water Operate switch When the operate button is pressed and released Line Voltage is supplied to the solenoid valve the solenoid valve opens and water sprays onto the heated steam generator The water flashes immediately into live steam and is forced up through the Black Manifold Plate orifices Lock Lever When in the full forward towards operator position the ...

Страница 11: ... avoid injury be careful when pulling basket assembly out from unit Be sure to allow steam to escape before putting hands or face over the steamer Operation continued Maintenance in the Maintenance section of this manual Steaming Tips Pre cooked pasta is easily reconstituted and gives you a hot product without the wetness of the normal dip method Experiment with your products and different steam i...

Страница 12: ... pull the locking lever forward to lock the plate 7 Check that the Water Pressure Regulator is cor rectly set at 20 25 PSI 1 4 to 1 7 kg cm2 or 138 172 kPa 8 Reinstall all parts and accessories Plug power cord into electrical outlet Maintenance Warning Turn the unit off disconnect the power source and allow the unit to cool down before performing any service or maintenance on the unit Maintenance ...

Страница 13: ...s safe to use on cast aluminum Observe all pre cautions and warnings on the product label 5 Using a sponge or dry towel remove the delimer solution from the generator surface then rinse with clear water NOTE To ensure proper steaming characteristics some calcium mineral deposits must be present on the generator surface If during cleaning the surface becomes free of calcium mineral deposits add pla...

Страница 14: ...iner screen 2 At the sink gently flush all of the accumulated debris from the strainer cup and mesh strainer Be especially careful not to damage the mesh strainer screen 3 Carefully place the mesh strainer screen into its seat at the bottom of the clear plastic cup and confirm that the orange O ring is properly seated in its place before screwing the strainer cup and top back together 4 Purge the ...

Страница 15: ...ty Steamer Components Top Cover Assy 1 Black Manifold Plate 2 Drip Tray 4 Diffuser 38 Spray Tube 37 O ring 3 Steam Generator Black Manifold Orifices Control Panel 32 Hi Limit Thermostat 35 Control Panel Screws 59 NOTE Numbers in parenthesis corre spond with replacement parts lists ...

Страница 16: ...indi cator light is on but the unit is not heating up Hi Limit thermostat is tripped Reset the Hi Limit according to the Operation section of this manual If it requires continuous resetting or repair contact your maintenance person or Authorized Service Agency for service Inoperable Thermostat Inoperable Generator Loose burnt wiring Unit heats but there is lit tle or no steam produced and or The p...

Страница 17: ...ring if worn damaged or missing Black Manifold is difficult to remove or re install onto the Generator Black Manifold not being removed and cleaned daily as required Remove and Clean the Black Manifold Daily according to the Maintenance section of this manual Black Manifold O ring is damaged or worn Replace the Black Manifold O ring if dam aged or worn Black Manifold O ring is not being lubri cate...

Страница 18: ...18 Variety STeamer P N 1010649 Rev E 03 07 Wiring Diagram Pictorial Wiring Diagram ...

Страница 19: ... Rev E 03 07 Replacement Parts 25 26 24 57 23 27 28 29 30 31 33 58 22 32 56 20 55 53 54 19 21 16 11 C 10 51 8 15 7 13 14 12 60 59 64 36 1 2 3 4 5 38 37 6 58 49 34 8 73 71 72 68 69 70 57 35 18 67 17 9 65 66 63 63 39 40 40 42 43 44 74 ...

Страница 20: ...witch Power On Off 1 28 2100123 Adjusting Knob 1 29 4010166 Switch Operate 1 30 4060208 LED Light Yellow Steam 1 31 4060179 LED Light Green Ready 1 32 0021043 Control Panel 1 33 402K169 Solid State Control 1 34 403K157 Thermostat 1 35 4030162 Hi limit Thermostat 1 36 0021046 Main Housing 1 37 0020269 Spray Tube 1 38 0500625 Diffuser 1 39 2100119 Large Basket Handle 1 40 2100240 Handle Guard Black ...

Страница 21: ...1 7 2110104 Clamp worm drive not shown 2 3 6 4 1 2 5 Replacement parts continued Item Part Description Qty No 64 040P111 Snap Bushing 1 65 325P104 Flat Washer 1 4 1 66 0503989 Bracket Hi Limit 1 67 See page 13 for Strainer Parts identification 68 325P169 Bolt Shoulder 5 16 x 1 2 1 69 212P120 Spacer St Stl 1 70 212P118 Flat Washer St Stl 1 71 325P154 Wash 1 4 Spring Lock 1 72 325P102 Nut Hex 1 4 20...

Страница 22: ...22 Variety STeamer P N 1010649 Rev E 03 07 NOTES ...

Страница 23: ...23 Variety Steamer P N 1010649 Rev E 03 07 NOTES ...

Страница 24: ...leage or any other charges for an Authorized Service Agency to reach the equipment location 2 Roundup reserves the right to make changes in design or add any improvements on any product The right is always reserved to modify equipment because of factors beyond our control and government regu lations Changes to update equipment do not constitute a warranty charge 3 If shipment is damaged in transit...

Отзывы: